Search results for "Instrumentation"

showing 10 items of 4914 documents

Role of nitric oxide and nitric oxide synthases in experimental models of denervation and reinnervation.

2001

Nitric oxide (NO) is a short-living free molecule synthesized by three different isoforms of nitric oxide synthases (NOS)—neuronal NOS, endothelial NOS, and inducible NOS—associated with neuromuscular transmission, muscle contractility, mitochondrial respiration, and carbohydrate metabolism in skeletal muscle. Neuronal NOS is constitutively expressed at the muscle fiber sarcolemma linked to the dystrophin-glycoprotein complex and concentrated at the neuromuscular endplate. There is increasing evidence that altered expression of neuronal NOS plays a role in muscle fiber damage in neuromuscular diseases such as dystrophinopathies and denervating disorders. Although there have been some previo…

DenervationHistologySarcolemmaNeuromuscular transmissionSynaptogenesisSkeletal muscleBiologyEndothelial NOSNitric OxideMuscle DenervationNitric oxideCell biologyMedical Laboratory Technologychemistry.chemical_compoundmedicine.anatomical_structureBiochemistrychemistrymedicineAnimalsHumansAnatomyNitric Oxide SynthaseMuscle SkeletalInstrumentationReinnervationMicroscopy research and technique
researchProduct

Ultra-fast intensified frame images from an electron cyclotron resonance hydrogen plasma at 2.45 GHz: some space distributions of visible and monochr…

2014

First results from an ultra-fast frame image acquisition diagnostic coupled to a 2.45 GHz microwave hydrogen discharge are presented. The plasma reactor has been modified to include a transparent doubled shielded quartz window allowing to viewing the full plasma volume. Pictures describing the breakdown process at 1μs exposure time have been obtained for integrated visible light signal, Balmer-alpha, Balmer-beta lines, and Fulcher-band. Several different plasma emission distributions are reported. The distribution depends on the magnetic field configuration, incident microwave power, and neutral gas pressure. peerReviewed

Dense plasma focusMaterials scienceta114business.industrymicrowave powerAstrophysics::Cosmology and Extragalactic AstrophysicsPlasmaElectron cyclotron resonancemagnetic field configurationPlasma windowOpticsPhysics::Plasma Physicsframe imagesgas pressurePlasma diagnosticsElectromagnetic electron waveAtomic physicsInductively coupled plasmabusinessInstrumentationMicrowaveThe Review of scientific instruments
researchProduct

Anomalous d-like surface resonances on Mo(110) analyzed by time-of-flight momentum microscopy.

2015

The electronic surface states on Mo(110) have been investigated using time-of-flight momentum microscopy with synchrotron radiation (hν=35 eV). This novel angle-resolved photoemission approach yields a simultaneous acquisition of the E-vs-k spectral function in the full surface Brillouin zone and several eV energy interval. (kx,ky,EB)-maps with 3.4 A(-1) diameter reveal a rich structure of d-like surface resonances in the spin-orbit induced partial band gap. Calculations using the one-step model in its density matrix formulation predict an anomalous state with Dirac-like signature and Rashba spin texture crossing the bandgap at Γ¯ and EB=1.2 eV. The experiment shows that the linear dispersi…

Density matrixPhysicsBand gapAngle-resolved photoemission spectroscopyLinear dichroismMolecular physicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsBrillouin zoneMomentumQuantum mechanicsInstrumentationSurface statesSpin-½Ultramicroscopy
researchProduct

Pulse Oximetry as a Diagnostic Tool to Determine Pulp Vitality: A Systematic Review

2021

Pulse oximetry (PO) can be used as a technique to assess vascularization. Although it is commonly used in the field of medicine, it still has limited use in dentistry. The aim of this study is to evaluate, by means of a systematic review, if pulse oximetry is a viable and effective system to determine pulp vitality and assess the clinical criteria for its use. A literature search was performed in Medline, Scopus, Embase, and Web of Science databases. Clinical studies using pulse oximetry as a tool to determine pulp vitality in permanent teeth were eligible. Quality assessment of the included studies was performed following the Quality Assessment for Diagnostic Accuracy Studies (QUADAS-2) gu…

Dental practicemedicine.medical_specialtydiagnosisMEDLINElcsh:Technologylcsh:Chemistry03 medical and health sciencespulp vitality0302 clinical medicinesystematic reviewTooth pulp stimulationmedicineGeneral Materials Science030212 general & internal medicineIntensive care medicineInstrumentationlcsh:QH301-705.5Fluid Flow and Transfer Processesmedicine.diagnostic_testbusiness.industryQuality assessmentlcsh:TProcess Chemistry and TechnologyGeneral Engineering030206 dentistryEndodonticslcsh:QC1-999Computer Science Applicationspulse oximetryPulse oximetryendodonticsCold testlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Pulp (tooth)businesslcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsApplied Sciences
researchProduct

GW170817: Implications for the Stochastic Gravitational-Wave Background from Compact Binary Coalescences

2018

The LIGO Scientific and Virgo Collaborations have announced the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star background will add to the background from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude $\Omega_{\rm…

Design sensitivityneutron star: binarygravitational radiation: stochasticAstronomyX-ray binaryGeneral Physics and AstronomyAstrophysicsAstrophysics01 natural sciencesGeneral Relativity and Quantum CosmologylocalizationGravitational wave backgroundGravitational Waves Neutron Stars Stochastic Background Virgo LIGOblack holeLIGOstochastic modelQCQBPhysicsGAMMA-RAY BURSTSSignal to noise ratioStochastic systemsBlack holesGravitational effectsarticleAstrophysics::Instrumentation and Methods for AstrophysicsComputingMethodologies_DOCUMENTANDTEXTPROCESSING[PHYS.GRQC]Physics [physics]/General Relativity and Quantum Cosmology [gr-qc]Gravitational wave sources Experimental studies of gravity Gravitational WavesGravitationBinary neutron starsX-ray bursterBinsAstrophysics::High Energy Astrophysical PhenomenaMERGERSFOS: Physical sciencesGeneral Relativity and Quantum Cosmology (gr-qc)Astrophysics::Cosmology and Extragalactic AstrophysicsGravity wavesgravitational radiation: direct detectionBinary pulsarNeutron starsSTAR-FORMATIONPhysics and Astronomy (all)General Relativity and Quantum CosmologyBinary black holebinary: coalescence0103 physical sciencesFrequency bandsddc:530RATESINTERFEROMETERS010306 general physicsAstrophysics::Galaxy AstrophysicsNeutronsGravitational Waves010308 nuclear & particles physicsGravitational waveVirgogravitational radiation: backgroundgravitational radiationAstronomyNeutron Stars530 Physikbinary: compactsensitivityStarsLIGObackground: stochasticEVOLUTIONsignal noise ratioVIRGOPhysics and Astronomyblack hole: binarygravitational radiation: emissionStellar black holeStochastic BackgroundDewey Decimal Classification::500 | Naturwissenschaften::530 | PhysikHIGH-REDSHIFTneutron star: coalescencePhysical Review Letters
researchProduct

Optical recognition and removal of Hg(II) using a new self-chemosensor based on a modified amino-functionalized Al-MOF

2017

Abstract We developed a simple self-chemical optical sensor for the monitoring and removal of ultra-trace levels of Hg(II) from aqueous media. The development of this sensor was based on the covalent attachment of amino-functionalized aluminum-based MOF particles with ninhydrin. The new sensor is densely coated with a chelating ligand to permit an ultra-fast, selective, pH-dependent visualization for removal of Hg(II) with detection limit (LOD∼0.494 μg L−1). Monitoring was accomplished via both a colorimetric signal visible to the naked eye as well as UV–vis absorption spectroscopy. Digital image-based colorimetric analysis has also used as a semi-quantitative analysis for determination the…

Detection limitAbsorption spectroscopyMetals and AlloysAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciences0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry.chemical_compoundchemistryCovalent bondNinhydrinMaterials ChemistryChelationNaked eyeElectrical and Electronic Engineering0210 nano-technologyColorimetric analysisInstrumentationSilver oxideNuclear chemistrySensors and Actuators B: Chemical
researchProduct

Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling

2012

A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of detection values ranging from 20 to 75 ng sampler−1and good repeatability values were obtained for VOCs under study with relative standard deviation values from 2.8 to 9.6% except for carbon disulfide for which it was 22.5%. The effect of the amount of chrome shavings per sampler was studied and resul…

Detection limitCarbon disulfideMaterials sciencelcsh:QD71-142Article SubjectGeneral Chemical EngineeringRelative standard deviationlcsh:Analytical chemistryRepeatabilityPolyethylenePulp and paper industrycomplex mixturesComputer Science ApplicationsAnalytical ChemistryLow-density polyethylenechemistry.chemical_compoundAdsorptionchemistryInstrumentationPassive samplingResearch ArticleJournal of Analytical Methods in Chemistry
researchProduct

Simultaneous determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using electrothermal atomic absorption spectrometry and …

2002

A method was developed for the simultaneous multi-element determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using an electrothermal atomic absorption spectrometer with a transversely heated graphite atomizer and longitudinal Zeeman-effect background correction. A fast furnace program with no pyrolysis stage or chemical modifier was used, and the total duration of the time-temperature program of the graphite furnace was 45 s. The method detection limits calculated from blank samples were 9.5 μg l−1, 0.18 μg l−1, 6.2 μg l−1 and 2.5 μg l−1 for As, Cd, Cr and Pb, respectively. Sample preparation procedures are briefly described. The accuracy of the method was confi…

Detection limitChromatographyChemistryAnalytical chemistrySedimentAtomic and Molecular Physics and OpticsAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawSoil waterAqua regiaSample preparationGraphiteAtomic absorption spectroscopyInstrumentationPyrolysisSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Determination of arsenite, arsenate, monomethylarsonic acid and dimethylarsinic acid in cereals by hydride generation atomic fluorescence spectrometry

2007

Abstract A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L− 1 H3PO4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g− 1 for As(III), As(V)…

Detection limitChromatographyChemistryHydridemedia_common.quotation_subjectExtraction (chemistry)Arsenatefood and beverageschemistry.chemical_elementAtomic and Molecular Physics and OpticsAnalytical ChemistrySpeciationchemistry.chemical_compoundCertified reference materialsInstrumentationSpectroscopyArsenicmedia_commonArseniteSpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Screening and authentication of tea varieties based on microextraction-assisted voltammetry of microparticles

2015

Abstract A simple electrochemical methodology for screening and authentication of green, black and red tea varieties is proposed. It is based on the record of the voltammetric response of microparticulate films of antioxidant compounds resulting from an ethanolic micro-extraction of commercial tea herbal preparations in contact with aqueous buffers. The obtained voltammetric responses led us to differentiate between diverse tea varieties upon application of bivariant and multivariant chemometric techniques, including discrimination of mixtures of teas with sensitivity estimated of 5.0 μA mg −1 with a detection limit of 0.01 mg of tea sample. Under the proposed conditions 100% discrimination…

Detection limitChromatographyChemistryMetals and Alloysfood and beveragesCondensed Matter Physicscomplex mixturesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsMaterials ChemistryHerbal preparationsElectrical and Electronic EngineeringInstrumentationVoltammetrySensors and Actuators B: Chemical
researchProduct