Search results for "Intraocular"
showing 10 items of 447 documents
Ahmed valve, suture-less implantation: A new approach to an easier technique.
2013
Purpose Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma. Patients and methods Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥ 21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-u…
Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma
2014
Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…
Suprachoroidal Bleeding After XEN Gel Implantation
2017
Purpose To report for the first time a clinical case of suprachoroidal bleeding after XEN45 gel implantation. Observations A 84-year old female patient with pseudoexfoliation glaucoma with intraocular pressure (IOP) (20 mm Hg) above target despite maximal IOP-lowering therapy was scheduled for XEN45 gel implantation. The XEN45 gel implantation went without complications and was properly placed in the anterior chamber and beneath the conjunctiva. On the first postoperative day, the patient presented with an IOP of 4 mm Hg, a functioning bleb and a deep anterior chamber. On the second day she developed suprachoroidal bleeding. A wait and see strategy was followed and the patient monitored ste…
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.
2011
Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…
Anterior chamber depth measurement in teenagers. Comparison of two techniques
2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…
Does the renin-angiotensin system also regulate intra-ocular pressure?
2009
The renin-angiotensin-aldosterone system is known to play an essential role in controlling sodium balance and body fluid volumes, and thus blood pressure. In addition to the circulating system which regulates urgent cardiovascular responses, a tissue-localized renin-angiotensin system (RAS) regulates long-term changes in various organs. Many recognized RAS components have also been identified in the human eye. The highly vasoconstrictive angiotensin II (Ang II) is considered the key peptide in the circulatory RAS. However, the ultimate effect of RAS activation at tissue level is more complex, being based not only on the biological activity of Ang II but also on the activities of other produ…
Argon laser suture lysis following glaucoma filtering surgery – A short introduction to the procedure
2010
Abstract Background Trabeculectomy is the most commonly performed glaucoma filtering surgery. The success of the outcome of an operation to reduce the intraocular pressure (IOP) is dependent on postoperative wound modulation by antimetabolite therapy and by flow regulation of the filtering bleb, which can be achieved by argon laser suture lysis. Methods and case report Postoperative IOP controls, examination of bleb formation and bleb massage can lead to the decision to perform up to four argon laser suture lyses in order to reduce IOP and enhance aqueous humor flow and bleb formation. The procedure is described here in a case report. Conclusion After glaucoma filtering surgery, argon laser…
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…