Search results for "Intraocular"

showing 10 items of 447 documents

The Damage of Ocular Surface Due to Uncontrolled Intraocular Pressure in Neovascular Glaucoma

2021

Abstract Neovascular Glaucoma (NVG) is a severe form of glaucoma characterized by neovascularization and the proliferation of fibrovascular tissue in the anterior chamber angle. Patients with NVG generally present with elevated intraocular pressure (IOP) and may experience severe pain. Ocular surface is affected by high IOP and can lead from moderated to marked conjunctival congestion that is frequently associated with edematous cornea. The aim of the study is to show how the high IOP can affect the ocular surface of the NVG patients and how we can treat and prevent the suffering. Materials and methods: We took in the study a number of 38 eyes from 35 patients with NVG in stage 3 with angle…

0301 basic medicinemedicine.medical_specialtyIntraocular pressuregenetic structuresbusiness.industryNeovascular glaucomaGeneral Medicineeye diseases03 medical and health sciences030104 developmental biology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicinesense organsbusinessOcular surfaceActa Medica Transilvanica
researchProduct

Impact of freeze-thaw cytoablation on aqueous outflow patterns in ex vivo anterior chamber perfusion cultures and whole eyes

2022

Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork a…

0301 basic medicinemedicine.medical_specialtyIntraocular pressuregenetic structuresvirusesGlaucomaTexas RedGeneral Biochemistry Genetics and Molecular Biology03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologymedicineFluoresceinGeneral Pharmacology Toxicology and PharmaceuticsGeneral Immunology and MicrobiologyChemistryvirus diseasesGeneral Medicinebiochemical phenomena metabolism and nutritionmedicine.diseasedigestive system diseases030104 developmental biologymedicine.anatomical_structure030221 ophthalmology & optometryOutflowTrabecular meshworksense organsPerfusionEx vivoF1000Research
researchProduct

Preservative-free fixed combination of tafluprost 0.0015% and timolol 0.5% in patients with open-angle glaucoma and ocular hypertension: results of a…

2017

Lutz E Pillunat,1 Carl Erb,2 Auli Ropo,3 Friedemann Kimmich,4 Norbert Pfeiffer5 1Department of Ophthalmology, University Hospital Carl Gustav Carus, Dresden, 2Augenklinik am Wittenbergplatz, Berlin, Germany; 3Santen Europe, Helsinki, Finland; 4eyecons, Pfinztal, 5Department of Ophthalmology, Mainz University Medical Center, Mainz, Germany Background: Efficacy, tolerability and safety of the novel preservative-free fixed combination of tafluprost 0.0015%/timolol 0.5% (Taptiqom®) were investigated in an observational study in Germany.Objective: To assess efficacy, tolerability and safety of the preservative-free fixed combination of tafluprost 0.0015%/timolol 0.5% in a real-life setti…

030213 general clinical medicinemedicine.medical_specialtyIntraocular pressureOpen angle glaucomagenetic structuresfixed combinationGlaucomaTimololOcular hypertension03 medical and health sciences0302 clinical medicineOphthalmologymedicineAdverse effectOriginal Researchpreservative-free medicationbusiness.industrytafluprostTafluprostClinical Ophthalmologymedicine.diseasetimololeye diseasesOphthalmologyglaucomaTolerability030221 ophthalmology & optometrysense organspreservativesbusinessmedicine.drugClinical Ophthalmology (Auckland, N.Z.)
researchProduct

Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity

2018

Aim To evaluate the repeatability of an optical device for measuring the Zernike coefficients of toric intraocular lenses (IOLs) and assess whether its toricity has any impact in its repeatability. Methods An experienced technician used the NIMO TR1504 to measure the Zernike coefficients 30 times for an aperture of 4.50 mm for all lenses included. The IOLs included were divided into two group: toric and non-toric ones. The cylindrical powers of the toric lenses included in the present study were 1.00, 1.50, 2.25, 3.00 and 3.75 D. Finally, the repeatability of the NIMO TR1504 was described in terms of within subject standard deviation (Sw) and repeatability limit. Results The Sw was smaller …

1144ApertureZernike polynomialsmedicine.medical_treatmentintraocular lensIntraocular lensStandard deviationlaw.invention03 medical and health sciencessymbols.namesake0302 clinical medicineOpticslcsh:OphthalmologylawMedicinerepeatabilityoptical qualitybusiness.industryRepeatabilityOptical qualityToric lensLens (optics)Ophthalmologyin-vitro measurementslcsh:RE1-994030221 ophthalmology & optometrysymbolsbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Visual simulation of different optical designs

2016

La presbicia es la pérdida irreversible de la capacidad de acomodar del ojo humano asociada a la edad, que afecta al rendimiento visual para con objetos cercanos. La presente Tesis Doctoral tiene como objetivo evaluar los aspectos ópticos y visuales de diferentes diseños multifocales para el tratamiento de la presbicia que se encuentran en lentes de contacto e intraoculares. En primer lugar, se implementó una métrica que facilita la evaluación in vitro de las lentes intraoculares. La idea de esta métrica se basa en la función de transferencia de modulación axial de las lentes intraoculares, la cual puede obtenerse con un instrumento de laboratorio adecuado. La métrica evalúa el volumen bajo…

:FÍSICA [UNESCO]Diseños MultifocalesUNESCO::FÍSICALentes de contactoCalidad opticaLentes IntraocularesPresbicia
researchProduct

Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…

2006

To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.

AdultAgingmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentSoftware toolScheimpflug principleIrisHigh resolutionIntraocular lensPhakic intraocular lensPreoperative careImaging Three-DimensionalLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinePreoperative CaremedicineHumansComputer SimulationPostoperative PeriodIris (anatomy)Lens crystallinebusiness.industryeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis

2004

PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…

AdultApplanation tonometrymedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SitueducationKeratomileusisGoldmann applanation tonometryTonometry OcularmedicineHumansPostoperative PeriodProspective StudiesIntraocular Pressurebusiness.industrySignificant differenceLASIKhumanitieseye diseasesSurgeryGoldmann tonometryOphthalmologyHyperopiaTreatment OutcomeRetreatmentsense organsbusinessCornea
researchProduct

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Spontaneous Resolution of Delayed Suprachoroidal Hemorrhage in the Single Eye Following Needling in Congenital Glaucoma

2017

Suprachoroidal hemorrhage (SCH) is a rare, but potentially vision-threatening event with poor long-term visual prognosis. At present, there is disagreement whether surgical intervention or conservative treatment is superior in the management. We report on a case of spontaneous resolution of severe SCH after needling procedure in the only eye of a young patient with congenital glaucoma.A 43-year-old woman with congenital glaucoma was scheduled for bleb needling in her only eye. Preoperative best-corrected visual acuity was 20/40 and intraocular pressure 20 mm Hg. On the third postoperative day, she developed a massive delayed SCH with appositional (kissing) choroidal bullae and visual acuity…

AdultChoroid Hemorrhagemedicine.medical_specialtyCongenital glaucomagenetic structuresRemission SpontaneousVisual AcuityGlaucomaSuprachoroidal hemorrhagePostoperative Hemorrhage03 medical and health sciences0302 clinical medicineOphthalmologyHumansMedicineIntraocular PressureDry needlingbusiness.industryGlaucomamedicine.diseaseConservative treatmentOphthalmology030221 ophthalmology & optometryDrainageFemalebusinessSclera030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct