Search results for "Intraocular"
showing 10 items of 447 documents
Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery.
2007
Purpose To determine whether implantation of a microincision intraocular lens (IOL) with a modified anterior surface, designed to compensate for the positive spherical aberration of the cornea in eyes of cataract patients, results in improved pseudophakic quality of vision in pseudophakic eyes after biaxial microincision phacoemulsification. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods In a nonrandomized parallel cohort investigation, the visual performance of 52 eyes of 52 patients unilaterally implanted with the aspherical Acri.Smart 36 A IOL (Acri.Tec) were compared with those of 25 eyes of 25 age-matched patients unilaterally implanted with…
Brinzolamide/brimonidine fixed-dose combination bid as an adjunct to a prostaglandin analog for open-angle glaucoma/ocular hypertension.
2019
Purpose: To evaluate the additive intraocular pressure–lowering effect of twice-daily brinzolamide 1%/brimonidine 0.2% fixed-dose combination (BBFC) as an adjunct to a prostaglandin analog (PGA) in patients with open-angle glaucoma or ocular hypertension insufficiently controlled with PGA monotherapy. Methods: In this Phase 4, double-masked trial, patients aged ⩾18 years, with a mean intraocular pressure of ⩾19 and <32 mm Hg in at least one eye were randomized (1:1) to receive BBFC + PGA ( n = 96) or vehicle + PGA ( n = 92) for 6 weeks. The primary endpoint was the mean change in diurnal intraocular pressure from baseline (averaged over 09:00 and 11:00 h) at Week 6. Results: The mean diu…
Lack of effect of intraocular lens asphericity on visual performance with acrylic intraocular lenses.
2011
Purpose. To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods. In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results. Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and…
Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses
2021
Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…
Relationship among Corneal Biomechanics, Refractive Error, and Axial Length
2014
Purpose To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickne…
Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis
2008
To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…
Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis
2010
To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …
Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery.
2009
To compare toric intraocular lens (IOL) implantation with paired opposite clear corneal incisions (OCCIs) for astigmatism correction in patients having cataract surgery.Ophthalmology Service, Donostia Hospital, San Sebastián, Spain.This randomized prospective clinical study comprised eyes with more than 1.00 diopter (D) of preexisting corneal astigmatism. One group had AcrySof toric IOL implantation and the other, paired 2.75 mm/3.20 mm OCCIs in the steep axis with spherical IOL implantation. Uncorrected (UCVA) and best corrected (BCVA) visual acuity, refraction, corneal and total higher-order aberrations (HOAs), photopic and mesopic contrast sensitivity, and toric IOL axis were measured 3 …
Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism
1999
Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…
Effect of head position on refraction in aphakic and phakic silicone-filled eyes.
1997
BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…