Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.
2016
Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…
Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia
2019
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…
Residual astigmatism produced by toric intraocular lens rotation.
2010
Purpose To analyze changes in the eye’s refractive properties when a toric intraocular lens (IOL) rotates. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Design Experimental study. Methods The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C1 and C2 whose axes form an angle a, is obtained by the addition of 2 vectors of values C1 and C2 forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part Fnes, the orth…
Correlation between optics quality of multifocal intraocular lenses and visual acuity
2009
Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …
Ahmed valve, suture-less implantation: A new approach to an easier technique.
2013
Purpose Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma. Patients and methods Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥ 21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-u…
Intravitreal pegaptanib sodium for refractory pseudophakic macular oedema.
2008
Evaluate the efficacy of intravitreal pegaptanib sodium (Macugen®) in refractory pseudophakic cystoid macular oedema (CME). Prospective, nonrandomized, interventional case series. Four eyes of four patients with refractory pseudophakic CME to pars plana vitrectomy and intravitreal bevacizumab and triamcinolone, were treated with pegaptanib sodium, with a mean follow up of 4 months. Pre- and postinfection examinations included assessment of best-corrected visual acuity (BCVA) using the Early Treatment Diabetic Retinopathy Study chart (ETDRS), fluorescein angiography (FA), and optical coherence tomography (OCT). Visual acuity increased in all patients after intravitreal pegaptanib sodium. OCT…
Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma
2010
Manuel Diaz-Llopis1,2,3, David Salom1,3, Salvador García-Delpech1,2,3, Patricia Udaondo1,3, Jose Maria Millan3,5, J Fernando Arevalo61Department of Ophthalmology, La Fe University Hospital of Valencia, Valencia, Spain; 2Department of Ophthalmology of the Valencia University, Valencia, Spain; 3Biomedical Network Research Centre on Rare Diseases (CIBERER), Valencia, Spain; 4Catholic University San Vicente Martir, Valencia, Spain; 5Department of Genetics, La Fe University Hospital of Valencia, Valencia, Spain; 6Clinica Oftalmologica Centro Caracas, Retina and VItreous Service, Caracas, DC, VenezuelaPurpose: To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahme…
The Prevalence of Glaucoma in Young People.
2017
BACKGROUND Earlier information on the prevalence of glaucoma among children in Germany was based solely on estimates. Reported values for congenital glaucoma range from 1 in 10 000 to 1 in 68 000 depending on ethnic origin. The estimate for juvenile glaucoma is 1 in 44 000. METHODS The Gutenberg Health Study is a populationbased, prospective, monocentric cohort study with 15 010 participants aged 35 to 74. To determine the history-based prevalence of childhood glaucoma, participants were asked about the diagnosis of glaucoma, any operations for glaucoma that were performed, regular use of drugs for glaucoma, and the age of onset of glaucoma. The affected individuals were classified in four …
Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients
2016
The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.