Search results for "Intraocular"
showing 10 items of 447 documents
Evaluation of the performance of multifocal intraocular lenses image quality: analysis of the standard methods
2007
Purpose: To analyze the standard methods used to describe intraocular lenses (IOL) and to suggest some improvements to make them applicable for multifocal IOLs. Methods: The EN-ISO standards and the standards of the American National Standards Institute (ANSI) for the evaluation of the performance of IOLs are tested for multifocal IOLs. The MTF of the one refractive multifocal IOL and two hybrid refractive-diffractive multifocal IOLs is measured for both distance focus and near focus and using different pupil sizes. Results: The average modulation (AM) from 0 to 100 c/mm of multifocal IOLs (for the distance focus) is about 40-50% lower than the AM of monofocal IOLs, for all pupil sizes stud…
Transient reduction of the ocular perfusion pressure and the oscillatory potentials of the ERG
2005
Abstract Purpose. To evaluate the changes of the Oscillatory Potentials (OPs) of Electroretinogram (ERG) caused by short-term hypertension in human subjects, and their relationship with ocular perfusion pressure (OPP). Methods. Suction cup technique in 12 normal volunteers with OPs simultaneously recording. Results. Scotopic and photopic OPs were altered during OPP drop. Scotopic OPs showed more sensitiveness, with higher reduction (from 21% to 47%), when compared to the basal value, than in photopic recordings (from 14% to 34%). In both conditions, the relationship between OPP and OPs presented a steady amplitude before the trough after the +30 step, and rapid recovery after OPP normalisat…
Correlation of Crystallin Expression and RGC Susceptibility in Experimental Glaucoma Rats of Different Ages.
2018
Glaucoma is one of the leading causes of blindness worldwide with age being an important risk factor. However, the pathogenesis remains poorly understood. Aim of this study was to focus on age-dependent molecular changes in an experimental animal model of glaucoma.Intraocular pressure was elevated in Sprague-Dawley rats aged 3, 14, and 47 weeks for a period of 7 weeks by episcleral vein cauterization. Ganglion cell loss was monitored by an immunohistochemical staining of the Brain-specific homeobox/POU (Pit-1, Oct-2, Unc-86) domain protein 3A positive cells in retinal flat-mounts and spectral-domain optical coherence tomography measuring the retinal nerve fiber layer thickness. Molecular pr…
Biomarkers for glaucoma: from the lab to the clinic
2017
Glaucoma, a leading cause of irreversible blindness worldwide, is often not diagnosed until many years after disease onset. Early and objective diagnostic measures are yet missing. Besides the main risk factor, an elevated intraocular pressure (IOP), age, sex, and ethnicity are known to affect disease progression and severity. Furthermore, oxidative stress, elevated glutamate concentrations, and an autoimmune component are considered possible risk factors. We could identify several potential proteomic biomarkers in glaucoma and examine distinct changes in the glaucomatous human retina proteome. Using an experimental autoimmune glaucoma animal (EAG) model we could demonstrate an IOP-independ…
Phake Intraokularlinsen
2004
Phakic intraocular lenses (PIOLs), which are located closer to the eye's nodal points than the anterior corneal surface, can provide superior optical quality for higher corrections because of retention of normal prolate corneal asphericity and larger effective optical zones. Improvements in the material and design of phakic intraocular lenses and their insertion devices combined with advances in the understanding of the anatomical and physiological interactions of the PIOLs with intraocular structures, have increased safety and efficacy. Safety of these implants over the long term remains a concern, but in several situations PIOLs are the refractive correction of choice. The purpose of this…
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.
2020
Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…
Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
2008
Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…
Outcome of Bleb Revision With Autologous Conjunctival Graft Alone or Combined With Donor Scleral Graft for Late-onset Bleb Leakage With Hypotony Afte…
2020
Prcis Treatment of leakage with ocular hypotony after trabeculectomy with mitomycin C (MMC) can be safely achieved through conjunctival patch alone or combined with donor scleral graft in cases of melted underlying sclera. Purpose To report outcomes of 2 surgical approaches for treating ocular hypotony in eyes with blebs with late-onset leakage after standard trabeculectomy with MMC. Methods Thirty consecutive cases with bleb leakage and hypotony underwent bleb revision surgery between 2009 and 2014 by the same surgeon (J.W.) at the Department of Ophthalmology of the Mainz University Medical Center, Germany. In 18 patients, an autologous conjunctival patch graft was applied. In 12 patients,…
Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation
2006
A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…
Role of nitric oxide synthase isoforms for ophthalmic artery reactivity in mice.
2014
Abstract Nitric oxide synthases (NOS) are involved in regulation of ocular vascular tone and blood flow. While endothelial NOS (eNOS) has recently been shown to mediate endothelium-dependent vasodilation in mouse retinal arterioles, the contribution of individual NOS isoforms to vascular responses is unknown in the retrobulbar vasculature. Moreover, it is unknown whether the lack of a single NOS isoform affects neuron survival in the retina. Thus, the goal of the present study was to examine the hypothesis that the lack of individual nitric oxide synthase (NOS) isoforms affects the reactivity of mouse ophthalmic arteries and neuron density in the retinal ganglion cell (RGC) layer. Mice defi…