Kosteneffektivitätsanalyse der Versorgung von Kataraktpatienten mit monofokalen Intraokularlinsen aus Sicht der Leistungserstatter

2003

BACKGROUND Data on the cost effectiveness of cataract surgery with respect to the German statutory health insurance system are hardly available. Hence the increase in visual acuity as primary efficacy endpoint, order of posterior capsule opacification as primary complication endpoint and direct cost for supplementation with monofocal intraocular lenses have been assessed via meta-analyses to evaluate the procedure's cost effectiveness from the perspective of the German statutory health insurance system. MATERIAL AND METHODS Using the medical internet database MEDLINE two meta-analyses on publications between 1995 and 2002 were carried out, one estimating the gained increase in visual acuity…

Visual acuitygenetic structuresCost effectivenessbusiness.industrymedicine.medical_treatmentEye diseaseOutpatient surgeryIntraocular lensCataract surgerymedicine.diseaseeye diseasesOphthalmologyInterquartile rangeMedicineOptometrymedicine.symptombusinessIncremental cost-effectiveness ratioKlinische Monatsblätter für Augenheilkunde
researchProduct

Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

2008

We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.

Visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityOpticsLens Implantation IntraocularMedicineContrast (vision)Humansmedia_commonWavefrontLenses Intraocularbusiness.industryeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual performance with multifocal intraocular lenses

2004

Abstract Objective To evaluate distance and near visual performance under bright (photopic) and dim (mesopic) conditions in patients who had undergone uncomplicated cataract extraction with multifocal or monofocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked, comparative, observational case series. Participants Thirty-two eyes of 32 patients after zonal-progressive multifocal IOL implantation (Allergan Medical Optics Array SA-40N) and 32 eyes of 32 age-matched patients after monofocal IOL implantation (Allergan Medical Optics SI-40NB). Intervention All eyes underwent phacoemulsification and IOL implantation. Main outcome measures At 18 months after surgery,…

Visual acuitygenetic structuresbusiness.industryMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectIntraocular lensPhacoemulsificationMultifocal intraocular lenseye diseasesOphthalmologymedicineOptometryContrast (vision)sense organsSpatial frequencymedicine.symptombusinessPhotopic visionmedia_commonOphthalmology
researchProduct

Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation11The authors have no commercial …

1999

Abstract Objective To objectively measure and compare halo, flicker, and glare disability in pseudophakic eyes with monofocal (MONO) and multifocal (MULTI) intraocular lenses (IOLs) with respect to the influence of corneal surface quality, astigmatism, and age. Design Prospective case series. Participants This clinical trial involved 28 eyes of 28 patients after small-incision cataract surgery with a MONO silicone IOL and 28 eyes of 28 patients with zonal-progressive silicone IOL. Intervention A computer program objectively determined halo, glare, and flicker. Corneal surface quality and astigmatism were measured using computerized videokeratography. Ray-tracing analysis was performed based…

Visual acuitygenetic structuresmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentGlare (vision)Intraocular lensCataract surgeryAstigmatismMultifocal intraocular lensmedicine.diseaseCorneal topographyeye diseasesOphthalmologyMedicineOptometrysense organsmedicine.symptombusinessDioptreOphthalmology
researchProduct

In vitro optical performance of a new aberration-free intraocular lens

2014

To assess the optical performance of the new EnVista intraocular lens (IOL). Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL’s aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield o…

WavefrontLenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials scienceCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentIntraocular lensequipment and suppliesProsthesis Designeye diseasesOptical qualityOphthalmologySpherical aberrationmedicine.anatomical_structureCorneaOphthalmologyOptical transfer functionLaboratory StudymedicineProsthesis designHumanssense organsCorneal Wavefront Aberration
researchProduct

Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs

2014

Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…

WavefrontOptics and PhotonicsPhakic Intraocular LensesMaterials sciencePolymersApertureZernike polynomialsbusiness.industryStrehl ratioPupilProsthesis DesignRefraction OcularPhakic intraocular lensSensory SystemsRoot mean squareOphthalmologySpherical aberrationsymbols.namesakeOpticssymbolsHumansSurgeryCollagenbusinessDioptreJournal of Cataract and Refractive Surgery
researchProduct

In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…

2012

Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…

WavefrontPhysicsLenses IntraocularOptics and Photonicsbusiness.industryAberrometryMultifocal intraocular lensModels TheoreticalArtificial Lens Implant MigrationProsthesis DesignRefraction OcularRefractionSensory SystemsCycles per degreeOphthalmologyOpticsTilt (optics)Optical transfer functionAberrometryOptometryHumansSurgerySpatial frequencybusinessJournal of cataract and refractive surgery
researchProduct

Tolerance to rotation of toric monofocal and bifocal intraocular lenses. A theoretical study

2018

Abstract This manuscript aims to evaluate the tolerance to rotation of a toric monofocal and a toric bifocal intraocular lenses with different cylinder powers. Theoretical designs based on wavefront aberrations were created to simulate a toric monofocal and a toric bifocal intraocular lens. Cylinder power ranged from −1 D to −6 D, in steps of −1 D. Tolerance to rotation was estimated by the visual Strehl ratio based on the optical transfer function (VSOTF) metric. Tolerance to rotation for both monofocal and bifocal intraocular lenses decreased when the cylinder power increased. For the bifocal design studied, the tolerance to rotation was larger for the near focus than for the far, however…

Wavefrontbusiness.industrymedicine.medical_treatmentStrehl ratioIntraocular lensRotation01 natural sciencesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials010309 optics03 medical and health sciences0302 clinical medicineOpticsIntraocular lensesOptical transfer function0103 physical sciences030221 ophthalmology & optometrymedicineCylinderElectrical and Electronic EngineeringFocus (optics)businessMathematicsOptik
researchProduct

Time course of IOP elevation, electroretinographic changes and retinal ganglion cell loss in a rat model of glaucoma induced by laser

2007

International audience; Purpose: To evaluate the time course of intraocular pressure (IOP) elevation, electroretinographic changes and retinal ganglion cell (RGC) loss in a rat model of glaucoma induced by photocoagulation of the trabeculum and the episcleral and limbal veins. Methods: Male Sprague Dawley rats were used at 6 weeks of age. At least 3 of the episcleral veins, the trabeculum and the limbal veins were photocoagulated with a laser at 532nm (Quantel Medical, Vitra) in one eye of the animals. IOP and electroretinogram (ERG) were monitored every 2 weeks during 11 weeks after photocoagulation. Three months after laser photocoagulation, the RGC population was identified with a 5% Flu…

[SDV.AEN] Life Sciences [q-bio]/Food and Nutritiongenetic structures[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organssense organs[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organselectroretinography: non-clinical[SDV.AEN]Life Sciences [q-bio]/Food and Nutritioneye diseasesganglion cellsintraocular pressure
researchProduct

Effect of the color of the intraocular lens on optical and visual quality

2014

Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a S…

choroidal thicknessmedicine.medical_specialtyVisual acuityrecurrenceorangegenetic structuresvisual acuityMesopic visionmedicine.medical_treatmentcontrast sensitivity functionIntraocular lensOrange (colour)Cataractsurgerylcsh:OphthalmologyOptical transfer functionOphthalmologymedicinescanning laser polarimetryfilterbusiness.industryChoroidenhanced depth imagingBoth lensesretinal nerve fiber layereye diseasesyellowOphthalmologyglaucomaIntraocular lensesFixed corneal compensationlcsh:RE1-994OptometryExotropiaOriginal Articlesense organsmedicine.symptombusinessPhotopic visionIndian Journal of Ophthalmology
researchProduct