Postoperative Lens Position Preoperatively Determined by Scheimpflug Photography
1999
The position of the artificial lens has an important influence on refractive power calculation. We compared the position of the crystalline lens with that of the artificial lens after cataract surgery by means of Scheimpflug photography. A difference in position of approximately 0.8 mm in the anterior direction could be determined.
Histology and Fine Structure of the Iris and Outflow System Following Latanoprost Therapy
2002
Latanoprost therapy can lead to iris darkening in susceptible individuals, particularly those with hazel eyes. Concerns have been raised about whether latanoprost, and for that matter other prostanoids, may have a harmful effect on the iris. In addition, it is unknown whether latanoprost causes increased pigmentation of the outflow pathways that might eventually lead to blockage and a type of pigmentary glaucoma. The present study summarizes findings from the authors' own laboratories on the effects of latanoprost as seen by light and electron microscopy of the iris and outflow tissues and reviews the as yet limited, relevant literature. The findings support the proposal that latanoprost-in…
Lens implant selection with absence of capsular support.
2001
If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…
Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…
2012
Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
2017
Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…
The "sandwich technique" for iris-fixated phakic intraocular lens implantation.
2006
ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]
Vacuoles in the Acrysof<sup>TM</sup> Intraocular Lens as Factor of the Presence of Serum in Aqueous Humor
2001
<i>Objective:</i> Acrysof™ (Alcon) foldable lenses (IOLs) have been shown to be highly biocompatible and exhibit a low incidence of posterior capsular opacification. However, minute vacuoles or ‘glistenings’ have been observed in some Acrysof IOLs. The clinical relevance of vacuole formation is presently unclear. To help clarify the influence of factors present under in vivo conditions on vacuole formation, the present experimental study examines the influence of aqueous humor components on the occurrence of vacuoles in Acrysof IOLs. <i>Methods:</i> A total of 12 sterile Acrysof IOLs (Alcon, MA60BM) were incubated at body temperature (37°C) for 3 or 6 months in anter…
Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus
2011
Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…
Anterior chamber depth measurement in teenagers. Comparison of two techniques
2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…
New Forceps and Spatula for Easy Retropupillary Implantation of Iris Claw Lenses in Aphakia: Experience in 4 Years of Use
2008
PURPOSE. Retropupillary implantation of an iris claw lens offers a rapid and atraumatic approach for rehabilitation of aphakic eyes. The difficulty in the implantation process arises because of the possibility of losing the intraocular lens (IOL) into the vitreous cavity and the need to change the hand holding the forceps during the enclavation. M ETHODS. The new forceps design radically changes the method of grasping an IOL. It contains an extendable supporting plate with a hook-like end. The instrument achieves a horizontal three-point fixation at the edge of the implant in the 6 and 12 o’clock position in order to prevent slippage into the vitreous cavity during the inclination. The supp…