Search results for "Intraoperative Complication"

showing 10 items of 69 documents

Single shot spinal anesthesia with very low hyperbaric bupivacaine dose (3.75mg) for hip fracture repair surgery in the elderly. A randomized, double…

2014

Single shot spinal anesthesia is used worldwide for hip fracture repair surgery in the elderly. Arterial hypotension is a frequent adverse effect. We hypothesized that lowering local anesthetics dose could decrease the incidence of arterial hypotension, while maintaining quality of surgical anesthesia.In a randomized double blinded study, 66 patients over the age of 65 years, with hip fracture needing surgical repair, were assigned to B0.5 group 7.5mg hyperbaric bupivacaine 5mg/ml (control group), and B0.25 group 3.75mg hyperbaric bupivacaine 2.5mg/ml (study group). Sensory and motor block level, and hemodynamic parameters including blood presure, heart rate and vasopressor dose administrat…

Malemedicine.medical_specialtyHemodynamicsCritical Care and Intensive Care MedicineAnesthesia SpinalFracture Fixation InternalDouble-Blind MethodHeart ratePressuremedicineHumansVasoconstrictor AgentsAnesthetics LocalEphedrineIntraoperative ComplicationsAdverse effectAgedAged 80 and overEphedrineBupivacaineSurgical repairHip fractureDose-Response Relationship DrugHip Fracturesbusiness.industryHemodynamicsmedicine.diseaseBupivacaineSurgeryAnesthesiology and Pain MedicineBlood pressureAnesthesiaFemaleHypotensionbusinessFollow-Up Studiesmedicine.drugRevista Española de Anestesiología y Reanimación
researchProduct

Targeting Moderate and Severe Male Stress Urinary Incontinence With Adjustable Male Slings and the Perineal Artificial Urinary Sphincter: Focus on Pe…

2017

Purpose: To analyze perioperative complications and postoperative explantation rates for selected readjustable male sling systems and the perineal single-cuff artificial urinary sphincter (AUS) in a large, contemporary, multi-institutional patient cohort. Methods: Two hundred eighty-two male patients who underwent implantation between 2010 and 2012 in 13 participating institutions were included in the study (n = 127 adjustable male sling [n = 95 Argus classic, n = 32 Argus T], n = 155 AUS). Perioperative characteristics and postoperative complications were analyzed. The explantation rates of the respective devices were assessed using the Fisher exact test and the Mann-Whitney U-test. A Kapl…

medicine.medical_specialtyIntraoperative ComplicationComplicationsUrologyUrinary Incontinence Stress030232 urology & nephrologyUrology610 Medicine & healthUrinary incontinencelcsh:RC870-923Artificial urinary sphincter03 medical and health sciencessymbols.namesake0302 clinical medicinemedicine610 Medicine & healthFisher's exact testbusiness.industryPerioperativeOdds ratiolcsh:Diseases of the genitourinary system. UrologyNeurology030220 oncology & carcinogenesisCohortsymbolsUrinary Sphincter ArtificialOriginal ArticleNeurology (clinical)medicine.symptomComplicationbusinessInternational neurourology journal
researchProduct

Iatrogenic perforation during colonoscopy in the endoscopic suturing era: surgical emergency or endoscopic clinical practice?

2019

Malemedicine.medical_specialtymedicine.diagnostic_testbusiness.industryGeneral surgeryAnastomosis SurgicalIatrogenic DiseaseSuture TechniquesPerforation (oil well)GastroenterologyEligibility DeterminationColonoscopyColonoscopyMiddle AgedKidney TransplantationClinical PracticeTreatment OutcomeIntestinal PerforationmedicineHumansSurgical emergencyIntraoperative ComplicationsbusinessEndoscopy
researchProduct

Virtual temporal bone: an interactive 3-dimensional learning aid for cranial base surgery.

2009

OBJECTIVE: We have developed an interactive virtual model of the temporal bone for the training and teaching of cranial base surgery. METHODS: The virtual model was based on the tomographic data of the Visible Human Project. The male Visible Human's computed tomographic data were volumetrically reconstructed as virtual bone tissue, and the individual photographic slices provided the basis for segmentation of the middle and inner ear structures, cranial nerves, vessels, and brainstem. These structures were created by using outlining and tube editing tools, allowing structural modeling either directly on the basis of the photographic data or according to information from textbooks and cadaver…

MaleEngineering drawingmedicine.medical_specialtyNeuronavigationSoftware ValidationWorkspaceVirtual realityprojectsNeurosurgical ProceduresUser-Computer InterfaceCadaverTemporal bonemedicineImage Processing Computer-AssistedHumansSegmentationIntraoperative ComplicationsNeuronavigationSkull BaseCranial Fossa Middlebusiness.industryVisible human projectDissectionTeachingTemporal BoneVisible Human ProjectsVestibulocochlear NerveSurgeryDextroscopeFacial Nerveprojects.projectEducation Medical GraduateEar InnerSurgeryNeurology (clinical)businessCarotid Artery InternalSoftwarePetrous BoneNeurosurgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…

2012

Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…

Aortic archEndoleakMedizinAnastomotic LeakAorta ThoracicChest painPatient Care PlanningAortic aneurysmPostoperative ComplicationsIntraoperative ComplicationsBrain DiseasesEndovascular ProceduresAngiographyEquipment DesignGeneral MedicineTreatment OutcomeCardiothoracic surgeryDescending aortacardiovascular systemCardiologyStentsmedicine.symptomCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyConsensusAortic DiseasesPerioperative CareSpinal Cord DiseasesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryInternal medicineMonitoring IntraoperativemedicineHumansAortaAortic Aneurysm Thoracicbusiness.industryContraindicationsPatient SelectionVascular System Injuriesmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic DissectionSurgerybusinessTomography X-Ray ComputedEchocardiography TransesophagealEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Management of incomplete regional anaesthesia in Germany: results of a nation-wide survey.

2007

Background:  Regional anaesthesia (RA) provides well-defined benefits with known attendant risks. However, incomplete blockade may introduce unanticipated risks depending on the compensatory measures employed. Until now, no data were available characterizing the pattern of response of German anaesthesiologists in this situation. This study analyses interventions in response to incomplete RA in a nation-wide setting. Methods:  A questionnaire was sent to every German anaesthesia department (n= 1381). Questions focused on interventions coping with an incomplete RA and differentiated between a pre- and a peri-surgical setting and measures to face pain outside the surgical field. If systemic su…

medicine.medical_specialtyCoping (psychology)SedationPsychological interventionPainRegional anaesthesiaAnesthesia GeneralPatient careAnesthesia ConductionPregnancyGermanymedicineHumansPain ManagementGeneral anaesthesiaIntraoperative ComplicationsAnestheticsPregnancybusiness.industryCesarean SectionSpinal anesthesiaGeneral Medicinemedicine.diseaseAnesthesiology and Pain MedicineAnesthesiaHealth Care SurveysEmergency medicineFemalemedicine.symptombusinessActa anaesthesiologica Scandinavica
researchProduct

Absolok® versus Hem-o-Lok® clips for renorrhaphy during partial nephrectomy for parenchymal renal tumors

2020

Background To compare perioperative and functional outcomes associated with renorrhaphy performed with two different types of clips (Absolok® vs. Hem-o-Lok®) in a contemporary series of patients who underwent partial nephrectomy. Methods Patients in whom Absolok® clips were used to perform haemostasis at the level of tumor bed or to block the running sutures during sliding-clip renorrhaphy (study group) were compared with a contemporary control group of patients in whom renorrhaphy was performed with Hem-o-Lok® clips. Both groups received the same surgical technique via an open or robot-assisted approach. Inner renorrhaphy was performed with one or more 3-0 (26 mm needle) monofilament runni…

MaleComplicationsmedicine.medical_treatment030232 urology & nephrologyKidneyNephrectomyPolydioxanonechemistry.chemical_compoundPostoperative Complications0302 clinical medicinePerioperative outcomesRobotic Surgical ProceduresSuture (anatomy)bsolok® clipPartial nephrectomyMedicineProspective StudiesCLIPSIntraoperative ComplicationsProspective cohort studycomputer.programming_languageMiddle AgedSurgical InstrumentsMagnetic Resonance ImagingRenal cell carcinomaKidney NeoplasmsNephrectomyTreatment Outcomesurgical procedures operativeNephrologyPolydioxanone030220 oncology & carcinogenesiscardiovascular systemFemalePositive Surgical MarginAbsolok (R) clips Hem-o-lok (R) clips Renorrhaphy Sliding clip technique Partial nephrectomy Perioperative outcomes Complications Renal cell carcinomaPerioperative outcomeHem-o-Lok® clipmedicine.medical_specialtyKidney CortexUrologyeducationSliding clip technique03 medical and health sciencesHumansRenorrhaphycardiovascular diseasesAgedHemostasisAbsolok (R) clipsSuturesbusiness.industryPerioperativeSurgeryHem-o-lok (R) clipschemistryHemostasisTomography X-Ray ComputedbusinessComplicationcomputerMinerva Urologica e Nefrologica
researchProduct

The influence of surgical experience on the rate of intraoperative aneurysm repture and its impact on aneurysm treatment outcome.

2001

Abstract BACKGROUND The influence of surgical experience on the result of aneurysm surgery remains unclear. To determine the impact of surgical experience we considered the occurrence of intraoperative aneurysm rupture (IAR) during microneurosurgery for intracranial aneurysms as an objective factor that could be evaluated. METHODS A retrospective study was performed on 379 consecutive patients with 490 cerebral aneurysms operated upon from 1989 to 1995. RESULTS IAR occurred in 6.7% of aneurysms and 8.7% of patients. There was a direct inverse relationship between the annual caseload of the surgeon and the risk of IAR. New neurological deficits (NND) occurred in 21% of patients with IAR, whi…

AdultMaleMicrosurgerymedicine.medical_specialtyAdolescentTreatment outcomeGlasgow Outcome ScaleWorkloadAneurysm RupturedNeurosurgical ProceduresCentral nervous system diseaseAneurysm ruptureAneurysmRisk FactorsAneurysm treatmentmedicineHumanscardiovascular diseasesChildIntraoperative ComplicationsOnderzoek NeurochirurgieAgedRetrospective StudiesAged 80 and overVascular diseasebusiness.industryInfantIntracranial AneurysmRetrospective cohort studyMiddle Agedmedicine.diseaseSurgeryTreatment OutcomeChild Preschoolcardiovascular systemFemaleSurgeryAneurysm surgeryClinical CompetenceNeurology (clinical)Radiologybusiness
researchProduct

Histamine release in mesenteric traction syndrome during abdominal aortic aneurysm surgery: prophylaxis with H1 and H2 antihistamines

2002

Objective and design: Mesenteric traction syndrome is described as sudden tachycardia, hypotension and flush. Among other etiological factors eventeration or mesenteric traction of the small intestine may cause histamine release from mesenteric mast cells. We hypothesized that mesenteric traction syndrome may be positively influenced by prophylactic antihistamine administration.¶Methods: Male patients (n = 17, ASA groups III-IV, 48–78 years old) were investigated in a randomised double blind study during elective abdominal aortic aneurysm (AAA) repair. Eight patients had pre-anaesthetic prophylaxis with dimetindene (H1-receptor antagonist) plus cimetidine (H2-receptor antagonist), 9 patient…

Malemedicine.medical_specialtymedicine.medical_treatmentImmunologyBlood PressurePlaceboHistamine Releasechemistry.chemical_compoundDouble-Blind MethodHeart RateTachycardiaFlushingmedicineDimethindeneHumansProspective StudiesSplanchnic CirculationCardiac OutputCimetidineIntraoperative ComplicationsPharmacologybusiness.industrySyndromemedicine.diseaseAbdominal aortic aneurysmSurgeryBlood pressureHistamine H2 AntagonistschemistryAnesthesiaDimetindeneHistamine H1 AntagonistsLaparoscopyAntihistamineHypotensionCimetidinebusinessVascular Surgical ProceduresHistamineAortic Aneurysm AbdominalAbdominal surgerymedicine.drugInflammation Research
researchProduct