Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up
2014
Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…
Prophylactic chimera anterolateral thigh/vastus lateralis flap: preventing complications in high-risk head and neck reconstruction
2014
Purpose In high-risk head and neck cases treated with tumor resection and associated radical neck dissection, orocutaneous fistulas and wound breakdowns in the neck are relatively frequent and can have serious consequences, such as carotid blowout syndrome (CBS), the need for salvage reoperations, and prolonged recovery time. The authors present the application of a prophylactic chimeric anterolateral thigh (ALT) and vastus lateralis (VL) flap to prevent complications. Materials and Methods A retrospective review was performed of a historical group (96 patients) of patients with head and neck cancer treated with tumor resection, radical neck dissection, and microsurgical reconstruction of t…
Water Jet Dissection in Neurosurgery: An Update After 208 Procedures With Special Reference to Surgical Technique and Complications
2010
Background Water jet dissection represents a promising technique for precise brain tissue dissection with preservation of blood vessels. In the past, the water jet dissector has been used for various pathologies. A detailed report of the surgical technique is lacking. Objective The authors present their results after 208 procedures with a special focus on surgical technique, intraoperative suitability, advantages, and disadvantages. Methods Between March 1997 and April 2009, 208 patients with various intracranial neurosurgical pathologies were operated on with the water jet dissector. Handling of the device and its usefulness and extent of application were assessed. The pressures encountere…
Iris-fixated toric phakic intraocular lens: Three-year follow-up
2006
Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…
Stentgraft-Implantation for Treatment of Internal Carotid Artery Injury during Endonasal Sinus Surgery
2007
Background Damage of the internal carotid artery (ICA) is very rare but can be a dramatic complication of endonasal sinus surgery. In the literature only a few cases are reported, some of them with fatal results. Methods We present two cases with massive bleeding of the ICA caused by endonasal sinus surgery. Results In both cases bleeding could be stopped sufficiently by implanting a stentgraft. Conclusion The lumen of the artery could be preserved and no neurological deficits were observed.
Adrenalectomy for Bilateral and Recurrent Pheochromocytoma: Increased Intraoperative Risk?
2006
Adrenalectomy for pheochromocytoma is per se associated with a specific intraoperative cardiovascular risk caused by catecholamine secretion during manipulation of the tumor. Bilateral or multiple, and recurrent chromaffine tumors are special subentities with a potentially more intensified and longer surgical preparation. The aim of our study was to examine these effects on hemodynamic changes compared with those observed for primary, solitary tumors. Of the 82 studied interventions between February 1992 and May 2005, 58 were seen to involve primary, unilateral tumors, 17 involved bilateral (1 trilateral) findings, and there were 7 cases of recurrency. The hemodynamic changes related to pri…
From laparoscopic assisted radical vaginal hysterectomy to vaginal assisted laparoscopic radical hysterectomy
2011
Radical hysterectomy with pelvic lymphadenectomy is the standard surgical treatment for patients with early stage cervical cancer. The majority of radical hysterectomies are performed with the open technique. However, laparoscopic, combined laparoscopic and vaginal, and robotic-assisted approaches may also be used. Compared with the abdominal radical hysterectomy (ARH), laparoscopic techniques are associated with less blood loss, shorter hospital stay, better cosmesis, and faster recovery. A further breakthrough in laparoscopic technique can only be made if safety and oncological clearance are comparable with ARH. We describe the technique and results of laparoscopic assisted radical vagina…
Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…
2012
Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…
Influence of root canal instrumentation and obturation techniques on intra-operative pain during endodontic therapy.
2012
Objective: To analyse the influence of root canal instrumentation and obturation techniques on intra-operative pain experienced by patients during endodontic therapy. Method and Materials: A descriptive cross-sectional study was carried out in Ponferrada and Sevilla, Spain, including 80 patients (46 men and 34 women), with ages ranged from 10 to 74 years, randomly recruited. Patient gender and age, affected tooth, pulpal diagnosis, periapical status, previous NSAID or antibiotic (AB) treatment, and root canal instrumentation and obturation techniques were recorded. After root canal treatment (RCT), patients completed a 10-cm visual analogue scale (VAS) that ranked the level of pain. Results…
Italian multicentric survey on laparoscopic spleen surgery in the pediatric population.
2007
Abstract Background: Some technical aspects of laparoscopic spleen surgery still are debated, although efforts have been made to standardize them. The position of the patient, the approach to the spleen, vessel identification and division, and spleen extraction can vary from center to center. Methods: This retrospective muticentric study led by the Societa` Italiana di Videochirurgia Infantile (SIVI) examined indications, surgical details, and complications of laparoscopic spleen surgery in the pediatric population during a 5-year period. Results: The study period from January 1999 to December 2003 (5 years) involved nine centers and included 85 patients with a mean age of 10 years (range, …