Search results for "Ion beam"
showing 10 items of 297 documents
Charge-state dynamics of 1.4- and 11-MeV/u uranium ions penetrating H2 and He gas targets
2018
Abstract Theoretical description and interpretation are presented of the recent experimental data on stripping of fast 238U ions, penetrating H2 and He gaseous targets: obtained in GSI, Darmstadt, Germany at 1.4 MeV/u with a H2 stripper, and in RIKEN, Saitama, Japan at 11 MeV/u with H2 and He strippers. Electron-loss and capture cross sections for uranium ions, interacting with H2 and He targets are calculated and used as input data in the BREIT code to obtain dynamic characteristics of uranium-ion beams: non-equilibrium and equilibrium charge-state fractions, mean and equilibrium charges, and equilibrium thicknesses. Special attention is paid for the calculation of the dynamic characterist…
A highly selective laser ion source for bunched, low emittance beam release
2004
A novel type of resonance ionization laser ion source (RILIS) is under development, which combines the advantages of laser ionization with those of a source-implemented ion trap. This laser ion source trap (LIST) system, based on a gas-filled linear radio-frequency quadrupole ion trap, decouples the evaporation and ionization process by introduction of a primary surface ion repeller. Apart from significantly enhancing the selectivity in radioactive ion beam production, optimum control on the temporal pulse structure and the emittance of the generated laser ion bunch is obtained. A variety of operational modes from quasi-dc to microseconds-bunched ion beams with variable repetition rate can …
Effects of neutron richness on the behavior of nuclear systems at intermediate energies
2012
We discuss results concerning the behavior of hot nuclear sources formed in 40 ,48Ca+40 ,48Ca reactions at 25 MeV/nucleon. A correlation between the neutron-to-proton ratio of the total systems and heavy residue production is found. This correlation underlines the strong role played by the neutron-to-proton ratio degree of freedom on the behavior of hot nuclei at intermediate energies. Comparisons of our data with Constrained Molecular Dynamics calculations confirm that a moderately stiff behavior of the symmetry potential must be used to reproduce experimental data. These findings open the way for future investigations with exotic beams at radioactive ion beam facilities. © 2012 American P…
Decay studies ofAu170,171,Hg171–173, andTl176
2004
The $^{170,171}\mathrm{Au}$ isotopes were produced in the fusion-evaporation reaction of a $^{78}\mathrm{Kr}$ ion beam with a $^{96}\mathrm{Ru}$ target. For $^{170}\mathrm{Au}$ the proton and $\ensuremath{\alpha}$ emission from the ground state were observed for the first time and the decay of the isomeric state was measured with improved accuracy. In addition, the decay of $^{171}\mathrm{Au}$ was measured with high statistics. A new $\ensuremath{\alpha}$-emitting nucleus $^{171}\mathrm{Hg}$ and the previously known $^{172}\mathrm{Hg}$ and $^{167,168,169,170}\mathrm{Pt}$ isotopes were also studied. The ground-state proton emission was identified for a new proton emitter $^{176}\mathrm{Tl}$ …
Beamline pulsing system for cyclotrons
1998
Abstract A beamline pulsing system for cyclotrons is presented. The function of this system is to modify the structure of a cyclotron ion beam guided to the desired research target by a beamline. In some in-beam experiments, an adjustment of the time structure of the beam is sometimes needed. This kind of situation occurs if, for example, the life time of the target material is longer than the period corresponding to the beam frequency. In this case, the frequency of the ion pulses hitting the target is 10–21 MHz depending on the frequency of the acceleration voltage. The adjustment of the ion beam pulse frequency is carried out by a beamline deflector. Deflection is achieved by feeding a h…
First measurement of radioisotopes by collinear laser spectroscopy at an ion-guide separator
1997
The first successful application of an ion-guide separator (IGISOL) for collinear laser spectroscopy of radioisotopes has achieved an efficiency comparable with the best obtained with catcher-ionizer facilities. The ion beam energy spread was determined to be less than 6 eV, allowing laser fluorescence resonance signals for the Ba-140,Ba-142,Ba-144 radioisotopes to be detected with high resolution and sensitivity. Applications of this technique to measuring nuclear properties of refractory elements and short lived isomers promises to be particularly advantageous.
Test of special relativity in an ion storage ring
1996
An accurate measurement of the Doppler effect in collinear laser spectroscopy has been performed at the TSR storage ring with electron cooled7Li+ ions atΒ=0.064. This experiment is a sensitive test of theγ=(1−Β2)−1/2 factor(Β=v/c) in the special theory of relativity. The Doppler shifted frequencies of the moving7Li+ ions are compared with calibrated molecular lines at rest. The frequencies at rest for the7Li+ ions are known from independent measurements. The Doppler shifted frequencies in the collinear experiment have been measured with a precision ofδv/v=6×10−9, mainly limited by the signal width of the resonance. A corresponding upper limit of 8×10−7 is deduced for any deviation of the ti…
Beam phase measurement system for the K130 cyclotron in Jyväskylä
1993
Abstract A phase measurement system for Jyvaskyla new K = 130 heavy ion cyclotron has been designed and realized. The phase measurement is done using a set of capacitive probes to detect phase information from the internal ion beam. This data is vital for tuning purposes to obtain an isochronous magnetic field and to maximize the ion beam intensity.
On the resonant neutrinoless double-electron-capture decay of ^{136}Ce
2011
Abstract The double-electron-capture Q value for the 136Ce decay to 136Ba has been determined at JYFLTRAP. The measured value 2378.53(27) keV excludes the energy degeneracy with the 0 + excited state of the decay daughter 136Ba at 2315.32(7) keV in a resonant 0 ν ECEC decay by 11.67 keV. The new Q value differs from the old adopted value 2419(13) keV (Atomic Mass Evaluation 2003) by 40 keV and is 50 times more precise. Our calculations show that the precise Q value renders the resonant 0 ν ECEC decay of 136Ce undetectable by the future underground detectors. We measured also the double-β decay Q value of 136Xe to be 2457.86(48) keV which agrees well with the value 2457.83(37) keV measured a…
Optimal β-beam at the CERN-SPS
2005
A β-beam with maximum (for 6He ions) or (for 18Ne) could be achieved at the CERN-SPS. We study the sensitivity to and δ of such a beam as function of γ, optimizing with the baseline constrained to CERN–Frejus (130 km), and also with simultaneous variation of the baseline, for a fixed ion flux. These results are compared to the standard scenario previously considered, with lower , and also with a higher option that requires a more powerful accelerator. We conclude that the sensitivity to CP violation and increases significantly with γ if the baseline is increased proportionally, while for the CERN–Frejus scenario the dependence on γ is mild provided γ is above 100.