Search results for "Ion chromatography"
showing 10 items of 314 documents
NEW GRAFT COPOLYMERS OF HYALURONIC ACID AND POLYLACTIC ACID: SYNTHESIS AND CHARACTERIZATION
2006
Abstract New graft copolymers have been synthesized, using hyaluronic acid (HA) as a hydrophilic backbone and polylactic acid (PLA) as an aliphatic polyester in order to obtain new polymeric derivatives of HA able to hydrophobically associate in an aqueous medium. Hyaluronic acid with low molecular weight was made soluble in organic solvent by transformation to its tetrabutylammonium (TBA) salt. Using the HA–TBA derivative, the reaction was performed in dimethylsulfoxide adding as a reagent the N -hydroxysuccinimide derivative of PLA. Two HA–PLA graft copolymers have been synthesized and characterized by FT-IR, 1 H NMR spectroscopy and gel permeation chromatography. The interaction between …
Determination of alkylamines in atmospheric aerosol particles: a comparison of gas chromatography–mass spectrometry and ion chromatography approaches
2014
Abstract. In recent years low molecular weight alkylamines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkylamines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography–mass spectrometry (GC-MS) and ion chromatography (IC), for the determination of alkylamines in aerosol particles. Alkylamines were converted to carbamates through derivatization with isobutyl chlorof…
Reactivity of anticancer metallodrugs with serum proteins: New insights from size exclusion chromatography-ICP-MS and ESI-MS
2010
International audience; A method based on the coupling of high resolution size-exclusion liquid chromatography using a polymer stationary phase with inductively coupled plasma mass spectrometry was developed to study the interactions of two metallodrugs - cisplatin and RAPTA-T - with the serum proteins albumin and transferrin. In contrast to previous approaches, the technique allowed the total recovery of the metals from the column and was able to discriminate between the different species of the metallodrugs and their complexes with the proteins at femtomolar detection levels. Metal binding was found to be dependent on the protein concentration and on the incubation time of the sample. Cis…
Thermodynamics of a polymer blend solution system studied by gel permeation chromatography and viscosity
1999
Binary and ternary interaction parameters and their derivatives have been calculated with the Flory-Huggins formalism developed for a ternary polymer system. The equilibrium compositions of the ternary system tetrahydrofuran/polybutadiene/polystyrene that forms two phases in equilibrium at 25°C have been used to solve the binodal equations. With this set of parameters, the viscosimetric interaction parameters have been computed. For the sake of comparison, the experimental viscosimetric parameter has been determined from intrinsic viscosity data of a polymer (3) in a "binary solvent" (solvent + polymer (2)). It has been clearly shown that composition-dependent parameters are necessary to re…
Production and characterisation of recombinant forms of human pulmonary surfactant protein C (SP-C):Structure and surface activity
2006
Udgivelsesdato: 2006-Apr Surfactant protein C (SP-C) is an essential component for the surface tension-lowering activity of the pulmonary surfactant system. It contains a valine-rich alpha helix that spans the lipid bilayer, and is one of the most hydrophobic proteins known so far. SP-C is also an essential component of various surfactant preparations of animal origin currently used to treat neonatal respiratory distress syndrome (NRDS) in preterm infants. The limited supply of this material and the risk of transmission of infectious agents and immunological reactions have prompted the development of synthetic SP-C-derived peptides or recombinant humanized SP-C for inclusion in new prepar…
Three-Dimensional Calibration for Routine Analyses of Bromide and Nitrate Ions as Indicators of Groundwater Quality in Coastal Territories
2019
Nitrate and bromide ions are generally considered indicators of anthropogenic pollution and seawater intrusion, respectively, in the groundwater of coastal territories. The analysis of these species is generally carried out with routine chromatographic analyses which generally afford partially merged or poorly resolved peaks. In the present paper a simple method for the correct evaluation of their concentration in water is reported. This method does not imply utilization of other instruments or technologies, only the mathematical elaboration of the data obtained from routine analysis of standard solutions containing the two species. Standard binary solutions of nitrate and bromide ions at d…
Species-Specific Aggregation Factor in Sponges
1978
An aggregation factor (AF) from the siliceous sponge Suberites domuncula has been isolated and purified by the following steps: Sepharose 2 B gel chromatography, sucrose gradient, Nonidet treatment, Sephadex G-100 gel chromatography and DEAE-Sephadex ion-exchange chromatography. By this procedure the AF was purified 1340-fold with a 63% yield nearly to homogeneity. The AF is originally associated with large particles, characterized by a sedimentation of 2200 S. These particles have been visualized electron microscopically; they are characterized by a filament-like shape of a length of 3400 A and a cross-sectional diameter of 230 A. The purified, low-molecular weight AF has a buoyant density…
Validation of (68)Ge/(68)Ga generator processing by chemical purification for routine clinical application of (68)Ga-DOTATOC.
2008
Abstract Introduction Imaging of somatostatin receptor expressing tumours has been greatly enhanced by the use of 68 Ga-DOTATOC and PET/CT. Methods In this work, a purification method for the 68 Ge/ 68 Ga generator eluate and a method to produce 68 Ga-DOTATOC suitable for clinical use were evaluated. The generator eluate was purified and concentrated on a cation-exchange cartridge in HCl/acetone media. The efficacy of this procedure in eliminating metal impurities from the 68 Ga solution was investigated by ICP-MS. The radiotracer quality was evaluated by radio-TLC, GC and γ-ray spectrometry. Results 68 Ga-DOTATOC preparations ( n =33) were carried out with a mean synthesis yield of 59.3±2.…
AAZTA5-squaramide ester competing with DOTA-, DTPA- and CHX-A″-DTPA-analogues: Promising tool for 177Lu-labeling of monoclonal antibodies under mild …
2021
Abstract Background Combining the advantages of both cyclic and acyclic chelator systems, AAZTA (1,4-bis(carboxymethyl)-6-[bis(carboxymethyl)]amino-6-methylperhydro-1,4-diazepine) is well suited for complexation of various diagnostic and therapeutic radiometals such as gallium-68, scandium-44 and lutetium-177 under mild conditions. Due to its specificity for primary amines and pH dependent binding properties, squaric acid (SA) represents an excellent tool for selective coupling of the appropriate chelator to different target vectors. Therefore, the aim of this study was to evaluate radiolabeling properties of the novel bifunctional AAZTA5-SA being coupled to a model antibody (bevacizumab) i…
Highly efficient separation of amines by electrokinetic chromatography using resorcarene-octacarboxylic acids as pseudo-stationary phases
1998
Abstract Resorcarene-octacarboxylic acids, macrocyclic molecules built up by four alkylidene-bridged resorcinol units, were synthesized and used as pseudostationary phases in electrokinetic chromatography (EKC). Resorcarenes provide a stable structure and good solubility in electrolytes even with organic modifiers. The high electrophoretic mobility of the resorcarene-octacarboxylic acids introduced here as pseudostationary phases is based on the eight partly deprotonated carboxylic groups. This offers a broad migration time window, which is the main parameter for the resolution of peaks. From three compounds with different alkyl chain lengths (C 1 , C 5 , C 11 ), the C 11 -resorcarene-octa-…