Search results for "Ion chromatography"
showing 10 items of 314 documents
Determination of organic and inorganic anions in insect haemolymph and midgut contents by ion chromatography
1997
A simple and rapid ion-exchange chromatographic method with conductimetric detection for the determination of carboxylic acids (succinic, malic and citric) and inorganic anions (chloride, phosphate and sulphate) in haemolymph and midgut content of Lepidoptera larvae is provided. The mobile phase is 0.975 mM phthalic acid at pH 4.1. The procedure of sample extractions was simple. Comparison of the results with whose reported in the bibliography showed that the values were similar. The ion-exchange chromatographic–conductimetric detection method permits the analysis of various organic and inorganic anions in small biological samples.
Evaluation of advanced silica packings for the separation of biopolymers by high-perforamnce liquid chromatography
1987
Non-porous monodisperse 1.5-μm silicas were allowed to react with (A) and (B) N-acetylaminopropyltriethoxysilane to generate bonded phases useful in high-performance hydrophobic-interaction chromatography (HIC). Differences in the selectivity were observed between he amide and the ether phase. Peak capacities between 10 and 30 were achieved for several proteins with the amide and ether phase packed into columns of 36 × 8 mm I.D. and elution of the proteins under chromatographic conditions in which the gradient volume, VG, was held constant by varying the gradient time between 20 and 2.5 min and the flow-rate between 0.5 and 4.0 ml/min. The S values derived from the dependences of log k′ on …
Microporous hypercrosslinked polystyrene Styrosorb as a restricted access packing in sample clean-up for high performance liquid chromatography. Part…
1993
Styrosorb is a beaded microporous polystyrene with particle sizes between 2 and 4 μm. In spite of hypercrosslinkage the material was seen to swell in organic solvents. The native material is functionalized with Tris-groups at the outer surface of the particles. The average pore diameter was determined as 1.45±0.3 nm from size exclusion data using polystyrene and polyethylene standards in THF. The reversed phase behavior of the restricted access phase Styrosorb was investigated by injection of two test mixtures. Mixture I contained five aromatic amines, mixture II consisted of AmperozideR and four related compounds. The optimum range of mobile phase composition was assessed so that analytes …
Comparative study of Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SW and SWXL columns in size-exclusion chromatography of proteins.
1988
Abstract A reduction of the mean particle diameter of silica-based packings in the size-exclusion chromatography (SEC) of proteins to about 5 μm generates the expected increase in column plate number over the traditional 10 μm SEC columns, as demonstrated for the Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SWXL columns. The slightly lower column efficiency of the TSK-Gel 3000 SWXL compared with the GF 250 column is compensated by the fact that the phase ratio of the 3000 SWXL column is higher by a factor of two. Hence both columns show nearly the same peak capacity of about 20–30. When the ionic strength of the eluent was changed by varying the salt concentration, the elution volum…
An automatic multidimensional chromatography system for purification of human uterine progesterone receptor and induction of polyclonal antibodies.
1986
Abstract This paper reports on the synthesis of Org2058-bonded microparticulate silicas and their use in affinity chromatography as the first step for the purification of human progesterone receptor. The development of microprocessor-controlled instruments allows all the various steps to be performed automatically. The various steps used for the purification of human progesterone receptor were carried out with the FPLC system: (1) affinity chromatography, (2) desalting of eluate on Sephadex G-25, (3) anion-exchange chromatography using a Mono Q column. With this procedure the receptor was purified approx. 10,000-fold within 24 h. The yield of receptor was generally 85–95%. Investigations wi…
Determination of hydroquinone and metal in photographic developer by reversed-phase ion-pair chromatography with amperometric detection
1988
Abstract Sodium 1-heptanesulphonate is used as an ion-pair reagent for the chromatographic separation of the two developing agents on a phenylsilica micro-column, with amperometric detection at an applied potential of + 0.75 V (vs. Ag/AgCl). No pretreatment of the developer is necessary. Linear calibration graphs were obtained in the range 10 −5 -1.5 × 10 −4 M.
An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.
2002
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…
Sulphonic acid strong cation-exchange restricted access columns in sample cleanup for profiling of endogeneous peptides in multidimensional liquid ch…
2006
Abstract In this work, the pore structural parameters and size exclusion properties of LiChrospher strong cation-exchange and reverse phase restricted access materials (RAM) are analysed. The molecular weight size exclusion limit for polystyrenes was found to be about 17.7 kDa, while for standard proteins, the molecular weight size exclusion limit was higher, at approximately 25 kDa. The average pore diameter on a volume basis calculated from the pore network model changes from 8.5 nm (native LiChrospher) to 8.6 nm (diol derivative) to 8.2 nm (sulphonic acid derivative) to 6.9 nm ( n -octadecyl derivative). Additional characterisations were performed on restricted access materials with nitr…
Evaluation of selected buffers for simultaneous determination of ionic and acidic pesticides including glyphosate using anion exchange chromatography…
2019
Ion chromatography coupled with mass spectrometry is an established technique for determination of ionic analytes, however, sophisticated buffer removal equipment is required to eliminate inorganic compounds from the eluate before introduction into the ion source of mass spectrometer. A standard high-performance liquid chromatography coupled with tandem mass spectrometry setup using an ion exchange column (Metrosep® A Supp 5) is proposed as an alternative approach. For that reason, some buffers including non-volatile carboxylic acid based solutions have been evaluated for simultaneous trace determination of ionic and acidic pesticides including glyphosate in the same extract without a need …
Preferential solvation of a dicyanate ester monomer and poly(sulfone) in different organic solvents by size-exclusion chromatography.
2002
Preferential solvation parameters A in the ternary systems solvent (1) -monomer (2) -polymer (3) were determined as a tool to measure the compatibility between the cyanate ester monomer Arocy B10 and poly(sulfone), PSF, in the presence of three organic solvents: tetrahydrofuran, dimethylformamide and dicloromethane. The A parameter was measured by size-exclusion chromatography at different monomer-to-polymer ratios. The quantitative evaluation was rigorously made at polymer-diluted conditions. PSF was found to be preferentially solvated by the monomer. Concerning the solvent used, systems containing tetrahydrofuran showed the strongest solvation, the lowest A values being those obtained in …