Search results for "Ionization Chamber"
showing 10 items of 34 documents
Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
2016
Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…
The FURIOS laser ion source at IGISOL-4
2013
Abstract The FURIOS laser ion source at the Accelerator Laboratory of the University of Jyvaskyla has been moved to a new location as a part of the IGISOL-4 facility. The laser ion source project had a high priority which allowed the transport of laser light to be optimized during the design phase. The laser resonators have been upgraded with a dual etalon configuration leading to greatly reduced laser linewidth. The transport efficiency of the dual-chamber gas cell has been determined using an alpha recoil source, with efficiencies ranging from a few percent in the beam interaction chamber to nearly 20% in the ionization chamber. In addition, we present recent results from the re-commissio…
Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte …
2015
Abstract In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncer…
Time-of-flight ERD with a 200mm2 Si3N4 window gas ionization chamber energy detector
2014
Abstract Low energy heavy ion elastic recoil detection work has been carried out in Jyvaskyla since 2009 using home made timing detectors, a silicon energy detector and a timestamping data acquisition setup forming a time-of-flight–energy telescope. In order to improve the mass resolution of the setup a new energy detector was designed to replace the silicon solid state detector, which suffered from radiation damage and had poor resolution for heavy recoils. In this paper the construction and operation of an isobutane filled gas ionization chamber with a 14 × 14 mm 2 100 nm thick silicon nitride window are described. In addition to greatly improved energy resolution for heavy ions, the dete…
Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging
2018
Abstract Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous studies based on spectrophotometry showed valuable dosimetric features of these gels in terms of X-ray sensitivity and diffusion of the ferric ions produced after irradiation. In this study, MRI was performed on the gels at 1.5 T with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA gels were found to offer good linearity in the range of 0–10 Gy and a stable signal for several hours after irradiation. The sensitivi…
Assaying multiple 125 I seeds with the well-ionization chamber SourceCheck 4π 33005 and a new insert
2015
PURPOSE To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck(4π) 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten (125)I seeds with one single measurement instead of measuring each seed individually. MATERIAL AND METHODS The material required is: a) the SourceCheck(4π) 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S K of one single seed at a time; b) a newly designed insert that accommodates ten s…
Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations.
2009
Current dosimetry protocols require geometrical reference conditions for the determination of absorbed dose in external radiotherapy. Whenever these geometrical conditions cannot be maintained the application of additional corrections becomes necessary, in principle. The current DIN6800-2 protocol includes a corresponding factor k(NR), but numerical values are lacking and no definite information about the magnitude of this correction is available yet. This study presents Monte-Carlo based calculations within the 6 MV-X photon field of a linear accelerator for a common used ion chamber (PTW31010) employing the EGSnrc code system. The linear accelerator model was matched to measurements, show…
Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams
2018
The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…
The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.
2014
Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…
A highly-segmented ΔE-time-of-flight wall as forward detector of the 4π-system for charged particles at the SIS/ESR accelerator
1993
Abstract At the SIS/ESR accelerator facility at GSI in Darmstadt the 4π-detector system FOPI is under construction at present. It is designed for the investigation of central collisions of heavy ions in the energy range up to 2 A GeV. As phase I of this detector a forward wall has been built and used in various experiments. It comprizes a total number of 764 scintillators with an additional shell of 188 thin ΔE -detectors in front of it and covers the full azimuth of the polar angles from 1° to 30°. The velocity and the nuclear charge of the fragments are determined by a combined time-of-flight and ΔE measurement.