Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

2020

The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…

PhysicsPhotonsPhotonRadiological and Ultrasound TechnologyMonte Carlo methodUncertaintyWater030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisIonizationAbsorbed doseIonization chamberRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingLaser beam qualityRadiometryMonte Carlo MethodRelative Biological EffectivenessPhysics in medicine and biology
researchProduct

Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube…

2015

Abstract Ultrasoft X-ray characteristic aluminum K alpha line (Al Kα with energy of 1.5 keV) is used in radiobiological experiments to study the effect of radiation on biological matter. A simple method to generate a continuous beam of those X-ray radiations is to bombarding an aluminum target with accelerated electrons using high voltage (HV). In this work, by varying the HV we study the characteristics of a photon beam generated by means of a cold cathode transmission X-ray tube. The anode is a thin (16 μm) aluminum foil supported by a copper grid. The spatial distribution of air kerma is measured using gafchromic films of HD-810 calibrated with a parallel plate free-air ionization chambe…

PhysicsRadiationbusiness.industryX-ray tubeAcceleration voltageCathodelaw.inventionAnodeKermaOpticslawIonization chamberCold cathodeAtomic physicsbusinessInstrumentationBeam (structure)Radiation Measurements
researchProduct

SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications

2013

Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…

PhysicsReproducibilitybusiness.industrymedicine.medical_treatmentTruebeamGeneral MedicineGantry angleRadiosurgeryLinear particle acceleratorSmall fieldIonization chambermedicineNew deviceNuclear medicinebusinessMedical Physics
researchProduct

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

2014

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm3 sized ion chambers covering 11×11 cm2, which spacing is 2.5 mm in the central 5.5…

PhysicsTime delay and integrationbiologybusiness.industryFlatness (systems theory)General MedicineIntensity-modulated radiation therapybiology.organism_classificationOpticsIonization chamberStandard protocolPatient dosebusinessNuclear medicineValenciaMedical Physics
researchProduct

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

2010

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…

Physicsbusiness.industryDetectorX-ray detectorGeneral MedicinePhoton countingFull width at half maximumOpticsQuality (physics)Ionization chamberSpectroscopybusinessNuclear medicineHalf-value layerMedical Physics
researchProduct

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

2015

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit …

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineCollimated lightKermaOpticsAbsorbed doseIonizationIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.

2012

In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can …

Physicsmedicine.medical_specialtyRadiological and Ultrasound TechnologyPixelbusiness.industryDetectorRadiosurgerySquare (algebra)OpticsIonizationIonization chambermedicineDosimetryAnisotropyHumansRadiology Nuclear Medicine and imagingMedical physicsRadiotherapy Intensity-ModulatedAnisotropybusinessRadiometryDiodePhysics in medicine and biology
researchProduct

End-to-end tests using alanine dosimetry in scanned proton beams

2018

This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…

Radiology Nuclear Medicine and ImagingMaterials sciencePelviMonte Carlo methodanthropomorphic phantomauditRadiation DosageImaging phantom030218 nuclear medicine & medical imaginglaw.inventionPelvisSynchrotron03 medical and health sciences0302 clinical medicinelawIonizationend to end testDosimetryHumansPencil-beam scanningRadiometryAlaninedosimetryRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-Assistedequipment and suppliesSynchrotron030220 oncology & carcinogenesisIonization chamberProtonProtonsHeadMonte Carlo MethodBeam (structure)SynchrotronsBiomedical engineeringHuman
researchProduct

Radon and material radiopurity assessment for the NEXT double beta decay experiment

2015

Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM

Radon mitigationPhysics - Instrumentation and DetectorsNuclear engineeringchemistry.chemical_elementFOS: Physical sciencesRadon7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)XenonCambres d'ionitzacióDouble beta decayGamma detectors (HPGe)0103 physical sciencesGamma spectroscopyNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentDetectors de radiació010308 nuclear & particles physicsIonization chambersCanfranc Underground LaboratoryMaterial radiopurityFísicaTime-Projection Chamber (TPC)Instrumentation and Detectors (physics.ins-det)Double beta decaySemiconductor detectorchemistry13. Climate actionNuclear countersEnvironmental scienceNeutrino
researchProduct

Delayed-neutron spectroscopy with 3He spectrometers

1977

Abstract The characteristics of a 3 He ionization chamber for high-resolution spectroscopy of β-delayed neutrons have been examined. The detector response function is given in the energy range 0.019–2.77 MeV. A considerably improved energy resolution has been achieved by minimizing effects due to pulse summing, detection of scattered neutrons, and microphonics, and is most evident in the low-energy part of the spectra.

Range (particle radiation)Materials scienceSpectrometerIonization chamberMicrophonicsNeutronGeneral MedicineAtomic physicsNuclear ExperimentSpectroscopyDelayed neutronSpectral lineNuclear Instruments and Methods