Search results for "Keratomileusis"

showing 10 items of 39 documents

Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome

2007

ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…

Adultmedicine.medical_specialtygenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituSurgical Flapslaw.inventionContrast SensitivitylawMicrokeratomeOphthalmologymedicineHumansContrast (vision)media_commonbusiness.industryLASIKEquipment DesignRefractive ErrorsLasereye diseasesRefractive Surgical ProceduresSurgeryOphthalmologyTreatment OutcomeFemtosecondSurgerysense organsbusinessSensitivity (electronics)Follow-Up StudiesPhotopic vision
researchProduct

Inter-observer variability of central corneal thickness measurements using non-contact specular microscopy after laser in situ keratomileusis.

2003

BACKGROUND The aim of this study was to investigate the inter-observer variability of central corneal thickness measurements carried out with a non-contact specular microscope in patients who had undergone myopic laser in situ keratomileusis. METHODS Twenty-six eyes of 26 subjects who had undergone myopic laser in situ keratomileusis were studied with the Topcon SP-2000P non-contact specular microscope (Topcon Corp, Tokyo, Japan). The mean of three consecutive measurements of the central corneal thickness was recorded by two investigators prior to and one month after myopic laser in situ keratomileusis. Results obtained by each of the two physicians were compared. RESULTS Prior to surgery t…

In situAdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusislaw.inventionCornealawOphthalmologymedicineMyopiaHumansBody Weights and MeasuresPostoperative PeriodObserver VariationMicroscopyExcimer laserbusiness.industryLASIKLasereye diseasesConfidence intervalOphthalmologySPECULAR MICROSCOPYOptometryFemalesense organsbusinessObserver variationOptometryClinicalexperimental optometry
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes

2012

Purpose To evaluate and compare intraocular pressures (IOPs) during flap preparations performed using 2 femtosecond lasers and a mechanical microkeratome in human donor globes. Setting University Medical Center Mainz, Mainz, and Euroeyes Clinic Stuttgart, Stuttgart, Germany. Design Experimental study. Methods A cannula was inserted through the optic nerve in human globes. The IOP was obtained continuously during flap preparation using the 60 kHz Intralase femtosecond laser, the 200 kHz Visumax femtosecond laser, or the Amadeus II microkeratome. For each experiment, a normal lamellar flap preparation (regular procedure) and a worst-case procedure (femtosecond laser interface was pressed agai…

Intraocular pressureMaterials sciencebusiness.industryCorneal StromaKeratomileusis Laser In SituLaserModels BiologicalSurgical FlapsTissue DonorsSensory Systemslaw.inventionTonometry OcularOphthalmologyOpticslawMicrokeratomeFemtosecondHumansLasers ExcimerSurgeryUniversity medicalbusinessIntraocular PressureJournal of Cataract and Refractive Surgery
researchProduct

Comparison of Intraocular Pressure During Corneal Flap Preparation Between a Femtosecond Laser and a Mechanical Microkeratome in Porcine Eyes

2011

To compare the increase in intraocular pressure (IOP) during corneal flap preparation in porcine eyes when using a femtosecond laser or a mechanical microkeratome.The present study was conducted at a university hospital and a private clinic.The vitreous IOP was directly measured with a cannula through the optic nerve in 24 porcine globes (n = 12 for each device). In the first procedure (worst-case procedure), the eye interface was lowered against the globe until abortion of the docking maneuver when using the IntraLase femtosecond laser (Abbott Medical Optics, Santa Ana, CA) or the suction ring was pressed very firmly against the globe when using the Amadeus microkeratome (Ziemer Ophthalmic…

Intraocular pressuremedicine.medical_specialtygenetic structuresSwineCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusisSurgical Flapslaw.inventionTonometry OcularlawMicrokeratomeOphthalmologyAnimalsMedicineIntraocular Pressurebusiness.industryUniversity hospitalLasereye diseasesOphthalmologyFemtosecondLasers Excimersense organsbusinessCornea
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis.

2007

We report a case of contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis (LASIK). A 50-year-old white man was referred to us for differences in visual perception in the peripheral field between the right eye, which had had LASIK, and the left eye, which was emmetropic. Linear meridional static perimetry was carried out in the 0- to 180-degree meridian using a Goldmann perimeter to assess the peripheral perimetric thresholds. There was a statistically significantly marked increased threshold in contrast sensitivity in the nasal and temporal fields from 40 degrees of eccentricity in the LASIK eye compared with that in the emmetropic eye. Eyes treated…

MaleVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentKeratomileusis Laser In SituVision DisordersVisual AcuityEmmetropiaKeratomileusisContrast SensitivityMedicineHumansmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographymedicine.diseaseeye diseasesSensory SystemsVisual fieldOphthalmologyMeridian (perimetry visual field)OptometryVisual Field TestsSurgerysense organsmedicine.symptomVisual FieldsbusinessJournal of cataract and refractive surgery
researchProduct

Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis

2008

To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…

Malemedicine.medical_specialtyRefractive errorPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisIntraocular lensProsthesis DesignCataractPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometryFemaleLasers ExcimerSurgerysense organsbusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.

2011

Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisCataract ExtractionRefraction OcularBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses Intraocularmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyGeneral MedicineMultifocal intraocular lensMiddle AgedCorneal topographySubjective refractionRefractioneye diseasesOphthalmologyHyperopiaFemalesense organsbusinessEuropean journal of ophthalmology