Search results for "Kinesiology"
showing 10 items of 41 documents
Kinematic characteristics of barefoot sprinting in habitually shod children
2018
Background Anecdotally, a wide variety of benefits of barefoot running have been advocated by numerous individuals. The influence of the alterations in the properties of the shoe on the running movement has been demonstrated in adults at submaximal jogging speeds. However, the biomechanical differences between shod and barefoot running in children at sprinting speeds and the potential developmental implications of these differences are still less examined. The purpose was to determine the potential differences in habitually shod children’s sprint kinematics between shod and barefoot conditions. Methods Ninety-four children (51 boys and 43 girls; 6–12 years-old; height, 135.0 ± 0.12 m; body…
Selective activation of shoulder, trunk, and arm muscles: A comparative analysis of different push-up variants
2015
Context The push-up is a widely used exercise for upper limb strengthening that can be performed with many variants. A comprehensive analysis of muscle activation during the ascendant phase (AP) and descendant phase (DP) in different variants could be useful for trainers and rehabilitators. Objective To obtain information on the effect of different push-up variants on the electromyography (EMG) of a large sample of upper limb muscles and to investigate the role of the trunk and abdomen muscles during the AP and DP. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants Eight healthy, young volunteers without a history of upper extremity or spine injury.…
In Patients with Grade I and II Ankle Sprains, Dynamic Taping Seems to Be Helpful during Certain Tasks, Exercises and Tests in Selected Phases of the…
2022
We aimed to investigate changes in postural stability on a stable surface after the application of dynamic tape for patients with inversion ankle sprains. This study enrolled 30 patients (age 25.5 ± 8.0 years) with grade I and II ankle sprains, which occurred 7–21 days before enrolment. Postural stability (balance, coordination, feedback) was assessed before and after the application of dynamic tape using a stabilographic platform. Three 32-s exercises were performed on the stabilographic platform, one with eyes open, one with eyes closed and one with visual feedback. After the application of dynamic tape, an improvement was observed in terms of the mean radius of sway (4.2 &pl…
Three-dimensional architecture of the whole human soleus muscle
2018
Background Most data on the architecture of the human soleus muscle have been obtained from cadaveric dissection or two-dimensional ultrasound imaging. We present the first comprehensive, quantitative study on the three-dimensional anatomy of the human soleus muscle in vivo using diffusion tensor imaging (DTI) techniques. Methods We report three-dimensional fascicle lengths, pennation angles, fascicle curvatures, physiological cross-sectional areas and volumes in four compartments of the soleus at ankle joint angles of 69 ± 12° (plantarflexion, short muscle length; average ± SD across subjects) and 108 ± 7° (dorsiflexion, long muscle length) of six healthy young adults. Microdissection and …
Effect of different ergonomic supports on muscle activity of dentists during posterior composite restoration
2019
BackgroundThe aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks.MethodsA one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability o…
Changes in sprint performance and sagittal plane kinematics after heavy resisted sprint training in professional soccer players
2019
Background Sprint performance is an essential skill to target within soccer, which can be likely achieved with a variety of methods, including different on-field training options. One such method could be heavy resisted sprint training. However, the effects of such overload on sprint performance and the related kinetic changes are unknown in a professional setting. Another unknown factor is whether violating kinematic specificity via heavy resistance will lead to changes in unloaded sprinting kinematics. We investigated whether heavy resisted sled training (HS) affects sprint performance, kinetics, sagittal plane kinematics, and spatiotemporal parameters in professional male soccer players.…
Validity and reliability of Veloflex to measure active cervical range of motion in asymptomatic and symptomatic subjects
2021
Background Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluat…
Validity and reliability of the DiCI for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects
2021
Background A higher risk of shoulder injury in the athletic and non-athletic population is frequently associated with strength deficits. Therefore, shoulder strength assessment can be clinically useful to identify and to quantify the magnitude of strength deficit. Thus, the aim of this study was to evaluate the validity and reliability of a DiCI (a new hand-held dynamometer) for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects. Methods Forty-three recreational athletes (29 males and 14 females; age: 22.1 ± 0.47 years; body mass: 68.7 ± 13.1 kg; height = 173.3 ± 9.7 cm) and 40 symptomatic subjects (28 males and 12 females; age: 49.9 ± 8.1 y…
A software tool to acquire, synchronise and playback multimedia data: an application in kinesiology
2000
Assessing the physical condition of the human body frequently requires evaluating different tests performed by different devices. This information has to be analysed simultaneously to derive conclusions, and so a temporal relationship must be established between the data sources. In this paper, synchronisation of the sources of information is achieved by synchronising the clocks of computers connected in a Local Area Network. A clock synchronisation protocol is used and a global time is stamped in each information data flow. During analysis, the time-stamp is used to playback the data in a synchronised way. The proposed system is valid for any medical application in which data synchronisati…
Effect of fatigue and gender on kinematics and ground reaction forces variables in recreational runners.
2017
The presence of fatigue has been shown to modify running biomechanics. Overall in terms of gender, women are at lower risk than men for sustaining running-related injuries, although it depends on the factors taken into account. One possible reason for these differences in the injury rate and location might be the dissimilar running patterns between men and women. The purpose of this study was to determine the effect of fatigue and gender on the kinematic and ground reaction forces (GRF) parameters in recreational runners. Fifty-seven participants (28 males and 29 females) had kinematic and GRF variables measured while running at speed of 3.3 m s−1 before and after a fatigue test protocol. T…