Search results for "Kinetic"

showing 10 items of 3064 documents

Impact of acidic/hydrothermal treatment on pore structural and chromatographic properties of porous silicas

1991

Abstract A series of commercial silicas and a laboratory made product were subjected to acidic/hydrothermal treatment with solutions of HCI, HNO3, H2SO4 and HF. The concentration of acid and the temperature and duration of treatment were varied. The specific surface area, content of metal impurities, types and concentration of surface hydroxyl and siloxane groups and crystallinity were determined for native and treated silicas. Only changes in the structural order of the surface could be assessed by means of 19Si cross-polarization magic angle spinning NMR spectrometry and electron diffraction. The native and acid-treated silicas were surface modified to n-octyl derivatives and tested under…

ChromatographyChemistryOrganic ChemistryKineticsGeneral MedicineReversed-phase chromatographyBiochemistryAnalytical ChemistryCrystallinitychemistry.chemical_compoundElectron diffractionSiloxaneSpecific surface areaMagic angle spinningPorosityJournal of Chromatography A
researchProduct

Gibbs' Dividing Surface between a Fixed-Charge Membrane and an Electrolyte Solution. Application to Electrokinetic Phenomena in Charged Pores

1999

The Gibbs model for the boundary between two phases consists of replacing the finite interfacial region, where the properties of the system change gradually, by a dividing surface which acts as a third phase of zero volume in which some magnitudes change abruptly. This thermodynamic concept was recently applied to a planar interface between a fixed charge membrane and an electrolyte solution.1 The continuous decrease of counterions with the distance from the charged surface is replaced by a step function, so that the diffuse double layer is ideally represented by a charged region depleted of all co-ions. Here the cylindrical geometry is analyzed, and the planar case is revisited by proposin…

ChromatographyChemistryThermodynamicsSurfaces and InterfacesElectrolyteConductivityCondensed Matter PhysicsSpace chargeStreaming currentIonElectrokinetic phenomenaMembraneStep functionElectrochemistryGeneral Materials ScienceSpectroscopyLangmuir
researchProduct

Spray Freeze Dried Lyospheres® for Nasal Administration of Insulin

2021

Pharmacologically active macromolecules, such as peptides, are still a major challenge in terms of designing a delivery system for their transport across absorption barriers and at the same time provide sufficiently high long-term stability. Spray freeze dried (SFD) lyospheres® are proposed here as an alternative for the preparation of fast dissolving porous particles for nasal administration of insulin. Insulin solutions containing mannitol and polyvinylpyrrolidone complemented with permeation enhancing excipients (sodium taurocholate or cyclodextrins) were sprayed into a cooled spray tower, followed by vacuum freeze drying. Final porous particles were highly spherical and mean diameters r…

ChromatographyChemistrylyophilizationPharmaceutical ScienceExcipientAbsorption (skin)PermeationArticleBioavailabilitynasal drug deliveryRS1-441Nasal AbsorptionFreeze-dryingPharmacy and materia medicamedicinepeptide formulationsNasal administrationMannitolporous particlespharmacokineticspray freeze dryingmedicine.drugPharmaceutics
researchProduct

Ionic liquids in separation techniques.

2007

The growing interest in ionic liquids (ILs) has resulted in an exponentially increasing production of analytical applications. The potential of ILs in chemistry is related to their unique properties as non-molecular solvents: a negligible vapor pressure associated to a high thermal stability. ILs found uses in different sub-disciplines of analytical chemistry. After drawing a rapid picture of the physicochemical properties of selected ILs, this review focuses on their use in separation techniques: gas chromatography (GC), liquid chromatography (LC) and electrophoretic methods (CE). In LC and CE, ILs are not used as pure solvents, but rather diluted in aqueous solutions. In this situation IL…

ChromatographyChromatography GasOrganic ChemistryElectrophoresis CapillaryIonic LiquidsGeneral MedicineReversed-phase chromatographyBiochemistryMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundChaotropic agentCapillary electrophoresisCountercurrent chromatographychemistryLyotropicIonic liquidSolventsGas chromatographyCountercurrent DistributionChromatography LiquidChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

A theoretical plate model accounting for slow kinetics in chromatographic elution.

2011

The chromatographic elution has been studied from different perspectives. However, in spite of the simplicity and evident deficiencies of the plate model proposed by Martin and Synge, it has served as a basis for the characterization of columns up-to-date. This approach envisions the chromatographic column as an arbitrary number of theoretical plates, each of them consisting of identical repeating portions of mobile phase and stationary phase. Solutes partition between both phases, reaching the equilibrium. Mobile phase transference between the theoretical plates is assumed to be infinitesimally stepwise (or continuous), giving rise to the mixing of the solutions in adjacent plates. This yi…

ChromatographyComputer simulationElutionChemistryOrganic ChemistryKineticsGeneral MedicineModels TheoreticalKinetic energyBiochemistryAnalytical ChemistryVolumetric flow rateSolutionsKineticsPharmaceutical PreparationsMass transferPartition (number theory)Theoretical plateChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Effects of polysorbate 80 on amiodarone intestinal absorption in the rat

1995

Abstract Amiodarone is a widely used anti-arrhythmic agent which shows physico-chemical properties that are highly suitable for diffusion across lipophilic absorbing membranes, however,.its low aqueous solubility could represent the rate-limiting step for absorption, making it erratic and variable. In a previous paper, the influence of an anionic surfactant (sodium lauryl sulphate) at variable supramicellar concentrations was studied. The absorption rate constants of amiodarone decreased as the surfactant concentration increased, and absorption was unusually fast at lower surfactant concentrations. The previously proposed equations for interpreting the relationships between the amiodarone a…

ChromatographyDiffusionPharmaceutical ScienceAmiodaronePolyvinyl alcoholIntestinal absorptionchemistry.chemical_compoundMembranePharmacokineticschemistryPulmonary surfactantmedicineAbsorption (chemistry)medicine.drugInternational Journal of Pharmaceutics
researchProduct

EVALUATION OF THE ELUTION STRENGTH OF THE SURFACTANT AND ORGANIC SOLVENT IN HYBRID MICELLAR MOBILE PHASES

2001

The global ability of a mixed mobile phase (with two or more modifiers) to elute a solute is often measured without distinguishing between the elution strength of each modifier. An algorithm is proposed to evaluate the elution strength of the modifiers in hybrid micellar mobile phases containing a surfactant and an organic solvent. The algorithm is based on a mechanistic retention model that takes into account the competing equilibria of solutes among aqueous-organic phase, micelle, and stationary phase. The change in the elution strength of surfactant and organic solvent with respect to the concentration of both modifiers is also examined. The results are discussed according to the values …

ChromatographyElutionChemistrySodiumClinical BiochemistryPharmaceutical ScienceChemical modificationchemistry.chemical_elementAlcoholBiochemistryMicelleMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundPulmonary surfactantPhase (matter)Journal of Liquid Chromatography & Related Technologies
researchProduct

Description of the retention behaviour in micellar liquid chromatography as a function of pH, surfactant and modifier concentration

1997

Abstract Micellar liquid chromatography permits the elution of solutes of diverse polarity. One of the most outstanding advantages of the technique is its capability of predicting the retention with high accuracy, as a function of different experimental variables. The separation of a group of compounds is usually optimized by varying the concentrations of surfactant and modifier in the mobile phase. The pH is, however, for many solutes, a variable that should be considered in the description of their elution behaviour. A global model that takes into account, simultaneously, the concentrations of surfactant and modifier, and the pH as chromatographic variables, is proposed for ionizable solu…

ChromatographyElutionOrganic ChemistryGeneral MedicineBiochemistryMicelleMicellar electrokinetic chromatographyCapacity factorAnalytical Chemistrychemistry.chemical_compoundchemistryPulmonary surfactantMicellar liquid chromatographyPhase (matter)Sodium dodecyl sulfateJournal of Chromatography A
researchProduct

Ion-exchange voltammetry at a surfactant-doped electrode: model of mass transfer kinetics to an anionic surface-charged electrode and its application…

2000

cited By 10; International audience; A theoretical model of mass transfer kinetics was developed for investigating the accumulation of cationic compounds at an anionic surfactant-doped screen-printed electrode. It was extended to an enzyme-generated cationic product for the indirect determination of alkaline phosphatase (AP). The model takes into account the analyte depletion, the kinetics of the ion-exchange reaction-diffusion and the kinetics of the enzymatic reaction. The relationship between the ion-exchange voltammetric anodic peak current and the enzyme incubation/accumulation time for a given concentration of AP was established and the validity of the theoretical model was verified e…

ChromatographyIon exchangeGeneral Chemical EngineeringKineticsInorganic chemistryCationic polymerizationSubstrate (chemistry)02 engineering and technologyBuffer solution010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistryElectrochemical gas sensorchemistry.chemical_compoundchemistryElectrodeElectrochemistry[CHIM]Chemical Sciences0210 nano-technologyVoltammetry
researchProduct

Kinetics of phenol removal by Nocardia species

1979

Phenol removal by pure cultures of Nocardia corallina was studied in a batch reacting system by estimating both the active biomass and the phenol concentration in the liquid during the experiments. A simple kinetic model was tested and the relative constants determined at 37°C.

ChromatographyKinetic modelChemistryKineticsBiomassGeneral MedicineNocardia speciesSettore MED/42 - Igiene Generale E ApplicataApplied Microbiology and BiotechnologyMicrobiologyNocardia corallinachemistry.chemical_compoundPure culturePhenolphenol Nocardia speciesBiotechnologyEuropean Journal of Applied Microbiology and Biotechnology
researchProduct