Search results for "LIFETIME"
showing 10 items of 212 documents
How to Sell SaaS: A Model for Main Factors of Marketing and Selling Software-as-a-Service
2011
Software-as-a-Service providers have been growing fast while the contemporary research literature has neglected analysis of their business-critical marketing and sales processes. In this paper we collect the key factors characterizing how to market and sell SaaS to business customers into an eight dimensional model. We also use an explorative multi-case study to observe six SaaS providers and validate the model. The interviewed providers emphasized use of the Internet for marketing communication while personal direct sale was the dominating sales approach. Customer acquisition cost was the key performance indicator for marketing and sales while customer lifetime value and churn were the KPI…
Summary of the HypHI Phase 0 experiment and future plans with FRS at GSI (FAIR Phase 0)
2016
WOS: 000381331200014
Positronium as a probe in natural polymers: decomposition in starch
2009
Ortho-positronium (o-Ps) is used as a probe in positron annihilation lifetime spectroscopy (PALS) experiments, to characterise the behaviour of free volumes in natural starch samples, as a function of temperature (T). Up to about 540 K, the o-Ps intensity, I(3), remains constant at 26.2% while its lifetime, tau(3), is found to increase linearly. Both parameters undergo a decrease above this T, due to the onset of decomposition, which results in a shrinking of the sample pellets. The results indicate that the glass transition temperature should be above 501 K. Data from thermal gravimetry analysis (TGA) measurements are well described by supposing a first order process for the survival proba…
The $^{144}$Ce source for SOX
2015
International audience; The SOX (Short distance neutrino Oscillations with BoreXino) project aims at testing the light sterile neutrino hypothesis. To do so, two artificials sources of antineutrinos and neutrinos respectively will be consecutively deployed at the Laboratori Nazionali del Gran Sasso (LNGS) in close vicinity to Borexino, a large liquid scintillator detector. This document reports on the source production and transportation. The source should exhibit a long lifetime and a high decay energy, a requirement fullfilled by the (144)Ce-(144)Pr pair at secular equilibrium. It will be produced at FSUE “Mayak” PA using spent nuclear fuel. It will then be shielded and packed according t…
Test of the electric charge conservation law with Borexino detector
2015
International audience; The new limit on the electron lifetime is obtained from data of the Borexino experiment. The expected signal from the e → γν decay mode is a 256 keV photon detected in liquid scintillator. Because of the extremely low radioactive background level in the Borexino detector it was possible to improve the previous measurement by two orders of magnitude.
Exploring the boundaries of the nuclear landscape : α-decay properties of 211Pa
2020
Employing the recoil ion transport unit (RITU) and a fusion-evaporation reaction, the α decay of 211Pa has been identified via the implantation-decay correlation technique through observation of chains up to four consecutive decays. An α-particle energy and half-life of 8320(40) keV and 3.8+4.6−1.4 ms, respectively, were measured, corresponding to favored α decay. In addition, more precise α-decay properties of 212Pa and 213Pa were obtained due to accumulated statistics. The present data were compared to those predicted by selected atomic mass models and it was used to estimate the possibility of observing proton emission from these isotopes. peerReviewed
Temperature dependence of O2 singlet photoluminescence in silica nanoparticles
2013
Abstract The near infrared singlet emission and photoluminescence lifetime of O 2 molecules embedded in silica nanoparticles are studied from room temperature down to 10 K. The area of the photoluminescence band under infrared excitation decreases for temperature above 100 K and the lifetime is shortened. These observations provide evidence of a thermally activated relaxation channel with activation energy of about 40 meV. This relaxation mechanism adds to the already known temperature independent electronic-to-vibrational coupling involving high energy vibrational modes of the host matrix or its impurities. The thermally activated process is suggested to consist in the breakage of the O 2 …
The Single Molecule Probe: Nanoscale Vectorial Mapping of Photonic Mode Density in a Metal Nanocavity
2009
International audience; We use superresolution single-molecule polarization and lifetime imaging to probe the local density of states (LDOS) in a metal nanocavity. Determination of the orientation of the molecular transition dipole allows us to retrieve the different LDOS behavior for parallel and perpendicular orientations with respect to the metal interfaces. For the perpendicular orientation, a strong lifetime reduction is observed for distances up to 150 nm from the cavity edge due to coupling to surface plasmon polariton modes in the metal. Contrarily, for the parallel orientation we observe lifetime variations resulting from coupling to characteristic λ/2 cavity modes. Our results are…
Measurement of the Spin of the Ω− Hyperon
2006
A measurement of the spin of the Omega(-) hyperon produced through the exclusive process Xi(c)(0)--Omega(-)K(+) is presented using a total integrated luminosity of 116 fb(-1) recorded with the BABAR detector at the e(+)e(-) asymmetric-energy B factory at SLAC. Under the assumption that the Xi(c)(0) has spin 1/2, the angular distribution of the Lambda from Omega(-)--LambdaK(-) decay is inconsistent with all half-integer Omega(-) spin values other than 3/2. Lower statistics data for the process Omega(c)(0)--Omega(-)pi(+) from a 230 fb(-1) sample are also found to be consistent with Omega(-) spin 3/2. If the Xi(c)(0) spin were 3/2, an Omega(-) spin of 5/2 could not be excluded.
A high-accuracy calibration method for temperature dependent photoluminescence imaging
2019
This work demonstrates a novel technique for calibrating temperature dependent photoluminescence (PL) images of silicon wafers with high accuracy. The PL signal is calibrated using a heat-controlled photoconductance (PC) stage integrated into the PL imaging system. The PC signal is measured in true steady state condition and used to determine the calibration constant under the same temperature and illumination as the PL image, thus providing a high-precision calibration. This results in a robust method for imaging of important physical parameters, such as the minority carrier lifetime and the implied voltage at different temperatures, as well as the temperature coefficients and the recombin…