Search results for "LIMIT"
showing 10 items of 2826 documents
Automated Determination of Ziprasidone by HPLC With Column Switching and Spectrophotometric Detection
2005
An isocratic high-performance liquid chromatography (HPLC) method with column switching and ultraviolet (UV) detection is described for quantitative analysis of the new antipsychotic drug ziprasidone. After centrifugation of serum or plasma samples and addition of fluperlapine as internal standard, the samples were injected into the HPLC system. On-line sample clean-up was conducted on a column (10 x 4.0 mm ID) filled with silica C8 material (20-microm particle size) using 8% (vol/vol) acetonitrile in deionized water as eluent. Ziprasidone was eluted and separated on ODS Hypersil C18 material (5 microm; column size 250 x 4.6 mm ID) using acetonitrile-water-tetramethylethylendiamine (50:49.6…
Exposure assessment approach through mycotoxin/creatinine ratio evaluation in urine by GC–MS/MS
2014
Abstract In this pilot survey human urine samples were analyzed for presence of 15 mycotoxins and some of their metabolites using a novel urinary multi-mycotoxin GC–MS/MS method following salting-out liquid–liquid extraction. Fifty-four urine samples from children and adults residents in Valencia were analyzed for presence of urinary mycotoxin and expressed in gram of creatinine. Three out of 15 mycotoxins were detected namely, HT-2 toxin, nivalenol and deoxynivalenol (DON). 37 samples showed quantifiable values of mycotoxins. Co-occurrence of these contaminants was also observed in 20.4% of assayed samples. DON was the most frequently detected mycotoxin (68.5%) with mean levels of 23.3 μg/…
Limitations of concurrently representing objects within view and in visual working memory
2020
AbstractRepresenting visibly present stimuli is as limited in capacity as representing invisible stimuli in visual working memory (WM). In this study, we explored whether concurrently representing stimuli within view affects representing objects in visual WM, and if so, whether this effect is modulated by the storage states (active and silent state) of memory contents? In experiment 1, participants were asked to perform the change-detect task in a simultaneous-representing condition in which WM content and the continuously-visible stimuli in view were simultaneously represented, as well as a baseline condition in which only the representations of visual WM content were maintained. The resul…
Effects on Heat Stress of a Flame-Retardant Ensemble for Aluminum Smelters
2000
A common belief is that a flame-retardant clothing ensemble will increase the level of heat stress over ordinary cotton work clothes. This is supported by bench tests on fabrics that indicate higher insulation and vapor resistance values for flame-retardant clothing. This research compared a flame-retardant clothing ensemble for an aluminum smelter (Zirpo wool shirt and FR8 denim pants) with typical cotton work clothing. Four young men walked on a treadmill at two work levels inside a climatic chamber under controlled conditions of heat stress. During each test, heart rate, core temperature, and skin temperatures were continuously monitored and recorded every 5 min. After a physiological st…
Analytical performance and clinical utility of a bioassay for thyroid-stimulating immunoglobulins.
2013
Abstract The analytical performance and the clinical utility of a thyrotropin receptor (TSHR)–stimulating immunoglobulin (TSI) bioassay were compared with those of a TSHR-binding inhibitory immunoglobulin (TBII) assay. Limits of detection (LoD) and quantitation (LoQ), assay cutoff, and the half-maximal effective concentration (EC50) were measured. Dilution analysis was performed in sera of hyperthyroid patients with Graves disease (GD) during antithyroid treatment (ATD). Titer was defined as the first dilution step at which measurement of TSI or TBII fell below the assay cutoff. The LoD, LoQ, cutoff, and EC50 of the bioassay were 251-, 298-, 814-, and 827-fold lower than for the TBII assay.…
Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist
2019
Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
2012
Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…
Changes in accommodative responses with multifocal contact lenses: a pilot study.
2011
Our aim was to evaluate induced changes in pupil and accommodative response for different accommodative stimuli with three different multifocal contact lenses (CLs). Accommodative and pupil responses with three aspheric multifocal CLs of simultaneous focus center near (PureVision Low Add, PureVision High Add and Focus Progressives) for two accommodative stimuli of -2.5 and -4.00 D were recorded in 10 young subjects. Accommodative response, peak velocity, and time constant of accommodation and pupil constriction were assessed. The measurements were evaluated in all the participants with distance-single vision CLs and with the three multifocal CLs. The monocular measurements were performed in…
Bayesian pharmacokinetic-guided prophylaxis with recombinant factor VIII in severe or moderate haemophilia A
2018
Introduction: Personalised pharmacokinetics (PK) using Bayesian analysis with limited sampling is assumed to help to optimise prophylaxis in haemophilia A (HA) patients. Materials and methods: Our prospective, observational study analysed the influence of PK parameters on clinical variables (bleeding rates, joint status, adherence, and consumption) using myPKFiT (R) in a cohort of twenty-one severe and moderate HA patients on prophylaxis with recombinant FVIII (Advate (R)) in two periods of one year, the first before PK-based tailoring and the second after PK-guided prophylaxis. Intra-individual and inter-individual coefficients of variation (CV) of half-life (t(1/2)) were calculated. Resul…
Ventilatory threshold during incremental running can be estimated using EMG shorts
2012
The present study examined whether shorts with textile electromyographic (EMG) electrodes can be used to detect second ventilatory threshold (V(T2)) during incremental treadmill running. Thirteen recreationally active (REC) and eight endurance athletes were measured for EMG, heart rate, blood lactate and respiratory gases during VO(2max) test (3 min ramps, 1 km·h(-1) increments). V(T)(2), onset of blood lactate accumulation (OBLA) and EMG threshold (EMG(T)) were determined. In athletes, OBLA occurred at 56 ± 6 mL·kg(-1)·min(-1), V(T2) occurred at 59 ± 6 mL·kg(-1)·min(-1), and EMG(T) at 62 ± 6 mL·kg(-1)·min(-1) without significant differences between methods (analysis of variance: ANOVA). In…