Search results for "LIMIT"

showing 10 items of 2826 documents

Derivations of quasi *-algebras

2004

The spatiality of derivations of quasi*-algebras is investigated by means of representation theory. Moreover, in view of physical applications, the spatiality of the limit of a family of spatial derivations is considered.

AlgebraMathematics (miscellaneous)quasi *-algebraslcsh:MathematicsFOS: Physical sciencesLimit (mathematics)Mathematical Physics (math-ph)lcsh:QA1-939Settore MAT/07 - Fisica MatematicaRepresentation theoryMathematical PhysicsMathematicsInternational Journal of Mathematics and Mathematical Sciences
researchProduct

Statistical Mechanics of the sine-Gorden Field: Part II

1985

From the work of the Part I we are now in a position to address ourselves to the main problem posed in these lectures — the evaluation of Z, (1.11), for the s-G field after canonical transformation to the action-angle variables (4.27).

AlgebraPoisson bracketField (physics)Position (vector)Canonical transformationStatistical mechanicsSineClassical limitMathematics
researchProduct

An improved cathode for alkaline fuel cells

2010

Abstract The use of nickel foam as an electrode substrate in alkaline fuel cells (AFCs) has been investigated for bipolar cells incorporating an electrically conducting gas diffusion layer (GDL). Improved performance, compared to a previous design, was obtained by adding an extra active layer (AL) composed of manganese (IV) oxide (MnO2) deposited onto carbon black. This new cathode design performed significantly better (130 mA cm−2 at 0.8 V and 25 °C) than the previous design (35 mA cm−2 under the same condition), especially at higher potential. It has been shown that the GDL is a key component of the gas diffusion electrode for both performance and durability, especially with liquid electr…

Alkaline fuel cellMaterials scienceGas diffusion electrodeRenewable Energy Sustainability and the EnvironmentAnalytical chemistryOxideEnergy Engineering and Power TechnologyElectrolyteCondensed Matter PhysicsCathodelaw.inventionDielectric spectroscopychemistry.chemical_compoundFuel TechnologyChemical engineeringchemistrylawElectrodeLimiting oxygen concentrationInternational Journal of Hydrogen Energy
researchProduct

Characterization and quantitation of mixtures of alkyl ether sulfates and carboxylic acids by capillary electrophoresis with indirect photometric det…

2003

The separation, characterization, and determination of mixtures of alkyl ether sulfates (AES) and fatty acids (C10-C16) in background electrolytes (BGEs) containing acetonitrile (ACN)-water mixtures is addressed. Due to inhibition of the ionization of the carboxylate groups, the migration time and the resolution between the fatty acids decreased when the water content of the BGE was reduced, but efficiency and resolution between the AES oligomers improved. The migration times increased and resolution improved by substituting 5% ACN by an equivalent amount of dioxane. A complete separation of the two surfactant classes, up to the AES oligomers with 8 ethylene oxide units (EOs) with respect t…

Alkanesulfonateschemistry.chemical_classificationDetection limitMolar concentrationChromatographyEthylene oxideCalibration curveFatty AcidsClinical BiochemistryCarboxylic AcidsElectrophoresis CapillaryBiochemistryOligomerAnalytical ChemistryMolecular WeightSurface-Active Agentschemistry.chemical_compoundCapillary electrophoresischemistryCalibrationSolventsCarboxylateAlkylELECTROPHORESIS
researchProduct

Determination of muscimol and ibotenic acid in mushrooms of Amanitaceae by capillary electrophoresis

2014

In this study, the CZE method for rapid quantitative and qualitative determination of ibotenic acid and muscimol in Amanita mushrooms naturally grown in Poland was developed. The investigations included the species of A. muscaria, A. pantherina, and A. citrina, collected in southern region of Poland. The studied hallucinogenic compounds were effectively extracted with a mixture of methanol and 1 mM sodium phosphate buffer at pH 3 (1:1 v/v) using ultrasound-assisted procedure. The obtained extracts were separated and determined by CZE utilizing a 25 mM sodium phosphate running buffer adjusted to pH 3 with 5% content of acetonitrile v/v. The calibration curves for both analytes were linear in…

AmanitaamanitaceaeSodiumAmanitaClinical Biochemistrycapillary electrophoresischemistry.chemical_elementBiochemistryAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresisLimit of DetectionAmanitaceaeChromatographybiologyChemistryElectrophoresis CapillaryReproducibility of Resultsbiology.organism_classificationPhosphateibotenic acidmuscimolMuscimolLinear ModelshallucinogensMethanolIbotenic acidElectrophoresis
researchProduct

Suitability of 1-hexyl-3-methylimidazolium ionic liquids for the analysis of pharmaceutical formulations containing tricyclic antidepressants

2018

Abstract The reversed-phase chromatographic behaviour of six tricyclic antidepressants (amitryptiline, clomipramine, doxepin, imipramine, nortryptiline and maprotiline) was examined in this work with acetonitrile-water mobile phases, in the absence and presence of the ionic liquids 1-hexyl-3-methylimidazolium chloride and 1-hexyl-3-methylimidazolium tetrafluoroborate, which have interesting features for the separation of basic compounds, in terms of peak shape combined with reduced retention. Tricyclic antidepressants are low polarity drugs that strongly associate to the alkyl chains of conventional stationary phases. They are also positively charged in the usual working pH range (2–8) in r…

AmitriptylineDrug CompoundingIonic LiquidsNortriptyline02 engineering and technologyAntidepressive Agents Tricyclic01 natural sciencesBiochemistryChlorideAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionBoratesmedicineSample preparationMaprotilineAcetonitrileAlkylchemistry.chemical_classificationChromatography Reverse-PhaseChromatography010401 analytical chemistryOrganic ChemistryImidazolesGeneral Medicine021001 nanoscience & nanotechnologyDoxepin0104 chemical scienceschemistryIonic liquidSpectrophotometry UltravioletDoxepin0210 nano-technologymedicine.drugTricyclicJournal of Chromatography A
researchProduct

Determination of barbiturates in urine by micellar liquid chromatography and direct injection of sample.

2000

Abstract A liquid chromatographic procedure for the determination of six barbiturates (barbital, diallyl barbituric acid, phenobarbital, butabarbital, amobarbital and pentobarbital) in urine samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C 18 analytical column and a guard column of similar characteristics. The UV detector was set at 240 nm. A study to select adequate composition of the micellar mobile phase for the separation of these compounds in urine samples is performed. Maximum resolution was achieved with a 0.07 M sodium dodecylsulphate-0.3% propanol at pH 7.4 eluent. Limits of detection at 240 nm were ranged between 0.13 μg ml −1 for diallyl barbit…

AmobarbitalClinical BiochemistryPharmaceutical Science1-PropanolBarbitalAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyDrug DiscoverymedicineHumansSample preparationPentobarbitalSpectroscopyDetection limitBarbituric acidChromatographyButabarbitalHydrogen-Ion ConcentrationchemistryAlkanesulfonic AcidsMicellar liquid chromatographyBarbitalPhenobarbitalBarbituratesCalibrationAmobarbitalmedicine.drugChromatography LiquidJournal of pharmaceutical and biomedical analysis
researchProduct

Amycolatopsis balhimycina gene expression under inorganic phosphate limitation

2009

Amycolatopsis balhimycina gene expression inorganic phosphate limitation
researchProduct

Costruzioni in zone sismiche - progetto e verifica a presso-flessione agli stati limite ultimi.

2004

Analisi Limite
researchProduct

Investigating the level of significance of the coherence function in cardiovascular variability analysis

2002

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…

Analysis of covarianceThreshold limit valueFrequency domainStatistical significanceStatisticsSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaEstimatorCoherence (signal processing)Cardiology and Cardiovascular MedicineTransfer functionSoftwareMathematicsSurrogate data
researchProduct