Search results for "LIMIT"
showing 10 items of 2826 documents
Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.
2007
The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…
Development of a Rapid Method for the Determination of Phenolic Antioxidants in Dark Chocolate Using Ultra Performance Liquid Chromatography Coupled …
2017
Development of a new comprehensive method based on one-step liquid-liquid extraction (LLE) combined with ultra-high-performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) for the determination of eight phenolic compounds in dark chocolate is demonstrated. The study focuses on the optimization of sample preparation, chromatographic separation and Orbitrap-HRMS detection parameters to adjust selectivity and sensitivity of the method. The LLE mixture of formic acid-water-acetonitrile (2:58:40, v/v) and hexane at the component ratio of 1:1 (v/v) was applied for sample preparation. The inter-day and intra-day precision expressed from the relative stand…
Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…
2019
Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…
Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.
2017
A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…
Experimental Study of the Oriented Immobilization of Antibodies on Photonic Sensing Structures by Using Protein A as an Intermediate Layer
2018
[EN] A proper antibody immobilization on a biosensor is a crucial step in order to obtain a high sensitivity to be able to detect low target analyte concentrations. In this paper, we present an experimental study of the immobilization process of antibodies as bioreceptors on a photonic ring resonator sensor. A protein A intermediate layer was created on the sensor surface in order to obtain an oriented immobilization of the antibodies, which enhances the interaction with the target antigens to be detected. The anti-bovine serum albumin (antiBSA)-bovine serum albumin (BSA) pair was used as a model for our study. An opto-fluidic setup was developed in order to flow the different reagents and,…
Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor
2012
We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…
Plasmonic Nanosensor Array for Multiplexed DNA-based Pathogen Detection
2019
In this research we introduce a plasmonic nanoparticle based optical biosensor for monitoring of molecular binding events. The sensor utilizes spotted gold nanoparticle arrays as sensing platform. The nanoparticle spots are functionalized with capture DNA sequences complementary to the analyte (target) DNA. Upon incubation with the target sequence, it will bind on the respectively complementary functionalized particle spot. This binding changes the local refractive index, which is detected spectroscopically as the resulting changes of the localized surface plasmon resonance (LSPR) peak wavelength. In order to increase the signal, a small gold nanoparticle label is introduced. The binding ca…
Multi-analyte method for the analysis of legacy and alternative brominated and chlorinated flame retardants in food products of animal origin using g…
2019
Abstract An analytical method was developed and validated for the analysis of 32 halogenated flame retardants (HFRs), including 13 polybrominated diphenyl ethers (PBDEs), 9 dechlorane-related compounds (DRCs) and 10 of the so-called alternative BFRs in food samples of animal origin. Gas chromatography (GC) coupled with magnetic sector high resolution mass spectrometry (HRMS) was used for the instrumental analysis. Intralaboratory validation of the developed method was performed in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ). Where possible, trueness was verified by the analysis of reference materials (RMs). Fo…
Determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine by capillary electrophoresis using ultraviolet absorba…
2002
Abstract Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast—one run could be performed within…
Determination of amphetamines in hair by integrating sample disruption, clean-up and solid phase derivatization
2016
The utility of matrix solid phase dispersion (MSPD) for the direct analysis of amphetamines in hair samples has been evaluated, using liquid chromatography (LC) with fluorescence detection and precolumn derivatization. The proposed approach is based on the employment of MSPD for matrix disruption and clean-up, followed by the derivatization of the analytes onto the dispersant-sample blend. The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. Different conditions for MSPD, analyte purification and solid phase derivatization have been tested, using amphetamine (AMP), methamphetamine (MET), ephedrine (EPE) and 3,4-methylenedioxymethamphetamine (MDMA)…