Search results for "LIMIT"

showing 10 items of 2826 documents

Effect of particle size distribution in laser-induced breakdown spectroscopy analysis of mesoporous V–SiO2 catalysts

2011

In this paper, the effect of particle size on Laser-Induced Breakdown Spectroscopy (LIBS) analysis of mesoporous V–SiO2 catalyst samples was investigated. The measurements were realized on three LIBS devices with different parameters. Concentrations of V in samples used for LIBS experiments previously determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES) varied from 1.2 to 4.7 w/w%. Granulometry of silica samples was modified by two grinding methods (conventional vibration mill and cryogenic mill) and three sets of samples with different particle size distributions were obtained. Ground samples were then deposited in the form of a thin layer on the adhesive tape a…

Detection limitMaterials scienceAnalytical chemistryVanadiumchemistry.chemical_elementAnalytical ChemistrychemistryParticle-size distributionParticle sizeLaser-induced breakdown spectroscopyEmission spectrumSpectroscopyMesoporous materialta116SpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Cylindrical optical microcavities: Basic properties and sensor applications

2011

Abstract A detailed theoretical analysis of the basic properties of whispering-gallery modes (WGM) of thin capillaries is presented. The sensitivity of the resonances, as well as the Q factor is analyzed as a function of the structural parameters of the capillary and the refractive index inside the capillary. A practical application where thin capillaries are used for the measurement of glucose concentration in water is presented as a chemical sensor demonstrator. A best sensitivity of 1.24 nm/% of glucose concentration in water is reported, which corresponds to more than 850 nm/RIU. Additionally, different experimental approaches are discussed to improve the sensitivity and the detection l…

Detection limitMaterials scienceCapillary actionbusiness.industryMicrofluidicsCondensed Matter PhysicsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOpticsRefractometerHardware and ArchitectureQ factorElectrical and Electronic EngineeringWhispering-gallery wavebusinessRefractive indexExcitationPhotonics and Nanostructures - Fundamentals and Applications
researchProduct

Resonance ionization mass spectroscopy for trace analysis of neptunium

1993

Resonance ionization mass spectroscopic (RIMS) measurements for trace analysis and spectroscopy of 237Np, the ecologically most important isotope of neptunium, are described. The chemical procedure for the separation of neptunium from aqueous samples as well as the preparation of filaments for RIMS are outlined. Several two- and three-step excitation schemes have been investigated in order to find suitable conditions for the sensitive detection of 237Np. Using a three-step, three-color excitation and ionization scheme an overall detection efficiency of 3×10−8 was obtained, resulting in a detection limit of 4×108 atoms (160 fg) of 237Np. The hyperfine structure splittings of the levels under…

Detection limitMaterials sciencePhysics and Astronomy (miscellaneous)NeptuniumGeneral EngineeringAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_elementPhotoionizationMass spectrometryNuclear magnetic resonancechemistryIonizationIonization energySpectroscopyHyperfine structureApplied Physics B Photophysics and Laser Chemistry
researchProduct

Cavity ring down spectrometry for disease diagnostics using exhaled air

2017

In this paper we report the current stage of the development of a cavity ring-down spectrometer (CRDS) system using exhaled human breath analysis for the diagnostics of different diseases like diabetes and later lung cancer. The portable CRDS system is made in ultraviolet spectral region using Nd:Yag laser 266 nm pulsed light. Calibration of the CRDS system was performed using generated samples by KinTek automated permeation tube system and self-prepared mixtures with known concentration of benzene and acetone in air. First experiments showed that the limits of detection for benzene and acetone are several tens of ppb.

Detection limitMaterials scienceSpectrometerAnalytical chemistrymedicine.disease_causeMass spectrometryLaserlaw.inventionchemistry.chemical_compoundBreath gas analysischemistrylawmedicineCalibrationBenzeneUltravioletBiophotonics—Riga 2017
researchProduct

Calibration of LA-ICP-MS via standard addition using dried picoliter droplets

2020

A novel microanalytical calibration approach for quantitative spatially resolved analysis of thin layered materials with laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is presented. This method relies on standard addition via the generation of dried pL-droplet residues. Therefore, a drop on demand dosing device based on a modified commercial ink cartridge and a dosing interface, both accessible via a self-constructed microcontroller, were developed. This dosing device enables the precise deposition of pL-droplets onto solid samples for the generation of residues with dimensions in the low μm-range. The LA-ICP-MS analysis of such residues allows calibration over at l…

Detection limitMaterials scienceThin sectionSample (material)010401 analytical chemistryAnalytical chemistry02 engineering and technologyRepeatability021001 nanoscience & nanotechnologyMass spectrometryLaser01 natural sciences0104 chemical sciencesAnalytical Chemistrylaw.inventionCartridgelawStandard addition0210 nano-technologySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Experimental Investigation of Fused Biconical Fiber Couplers for Measuring Refractive Index Changes in Aqueous Solutions

2016

A detailed experimental study of a simple and compact fiber optic sensor based on a fused biconical fiber coupler is presented, in which the sensitivity is improved by operating the coupler beyond the first coupling cycle. The sensor is demonstrated to perform high sensitivity measurements of refractive index changes by means of variation of sugar concentration in water. The device is operated to achieve a linear transmission response, allowing a linear relation between the sugar concentration and the output signal. The initial sensitivity was measured as 0.03 units of normalized transmission per unit of sugar concentration (g/100 mL), with a noise detection limit of a sugar concentration o…

Detection limitMaterials sciencebusiness.industryAnalytical chemistryPolarization-maintaining optical fiber02 engineering and technologyGraded-index fiber020210 optoelectronics & photonicsNormalized frequency (fiber optics)OpticsFiber optic sensor0202 electrical engineering electronic engineering information engineeringFiber optic splitterElectrical and Electronic EngineeringbusinessInstrumentationRefractive indexPhotonic-crystal fiberIEEE Sensors Journal
researchProduct

Influence of water sample storage protocols in chemiluminescence detection of trace elements.

2002

This paper shows the influence of different sample storage protocols, on the chemiluminescence signal of some metal ions. The storage protocols studied were: acid addition (HCl or HNO(3)) and no reagent addition to filtered and refrigerated (T=4 degrees C) samples. Light emission was produced for the chemiluminescence reaction between luminol and hydrogen peroxide in buffer carbonate conditions (pH 10.8) catalysed by Cr(III), Co(II) and Cu(II). Batch and/or flow modes in different conditions were tested. Fe(II), Fe(III), Ni(II) and Mn(II) did not give chemiluminescence in the studied conditions. A parallel study of sensitivity and selectivity was performed. Then the presence or absence of t…

Detection limitMetal ions in aqueous solutionAnalytical chemistryAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundchemistrylawReagentLight emissionHydrogen peroxideMasking agentChemiluminescenceTalanta
researchProduct

A conjugated polymer with ethyl 2-(2-(pyridin-2-yl)-1H-benzo[d]imidazol-1-yl) acetate units as a novel fluorescent chemosensor for silver(I) detection

2013

Abstract A novel conjugated polymer ( P1 ) containing fluorene and ethyl 2-(2-(pyridin-2-yl)-1 H -benzo[ d ]imidazol-1-yl)acetate (PBMA) was designed and successfully synthesized through the Sonogashira coupling reaction. P1 shows high sensitivity and selectivity for Ag + detection in comparison to other metal cations. Upon addition of Ag + , the fluorescent emission of the polymer solution in THF was quenched dramatically, accompanying the color changed from blue to green. The detection limit for Ag + was 5 × 10 −8  mol L −1 . However, the similar copolymers P2 and P3 containing 2-(pyridin-2-yl)-1 H -benzo[ d ]imidazole and 2-(thiophen-2-yl)-1 H -benzo[ d ]imidazole, respectively, did not …

Detection limitMetals and AlloysSonogashira couplingFluoreneConjugated systemCondensed Matter PhysicsPhotochemistryFluorescenceMedicinal chemistrySurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry.chemical_compoundchemistryMaterials ChemistryProton NMRImidazoleElectrical and Electronic EngineeringSelectivityInstrumentationSensors and Actuators B: Chemical
researchProduct

Microwave-assisted vapour-generation Fourier transform infrared spectrometric determination of carbonate in waters

1998

Abstract A microwave-assisted vapour-generation Fourier transform infrared spectrometric procedure is proposed for the determination of total carbonate in waters. The method is based on the simultaneous injection of 100 μl of sample and 300 μl of 0.1 M nitric acid in a two-channel manifold with a merging zone; a coil located inside a microwave oven encourages the removal of CO 2 . The carbon dioxide is separated from the distilled water employed as carrier by means of gas–liquid separator and is introduced by a nitrogen carrier flow inside a long-path infrared absorption gas cell, from which the corresponding flow analysis recording is registered as a function of time in the wavenumber rang…

Detection limitMicrowave ovenAnalytical chemistryInfrared spectroscopyBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeFourier transformchemistryDistilled waterNitric acidsymbolsEnvironmental ChemistryCarbonateFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Determination of mercury in rice by cold vapor atomic fluorescence spectrometry after microwave-assisted digestion.

2010

Abstract A cold vapor atomic fluorescence spectrometry method (CV-AFS) has been developed for the determination of Hg in rice samples at a few ng g−1 concentration level. The method is based on the previous digestion of samples in a microwave oven with HNO3 and H2O2 followed by dilution with water containing KBr/KBrO3 and hydroxylamine and reduction with SnCl2 in HCl using external calibration. The matrix interferences and the effect of nitrogen oxide vapors have been evaluated and the method validated using a certified reference material. The limit of detection of the method was 0.9 ng g−1 with a recovery percentage of 95 ± 4% at an added concentration of 5 ng g−1. The concentration level …

Detection limitMicrowave ovenAnalytical chemistrychemistry.chemical_elementTin CompoundsOryzaHydrogen PeroxideMercuryBiochemistryNitric AcidAnalytical ChemistryDilutionMercury (element)Cold Temperaturechemistry.chemical_compoundHydroxylamineCertified reference materialsSpectrometry FluorescencechemistryEnvironmental ChemistryNitrogen oxideGasesMicrowave digestionMicrowavesSpectroscopyAnalytica chimica acta
researchProduct