Search results for "Lasers"
showing 10 items of 316 documents
Calibration of the photon spectrometer PHOS of the ALICE experiment
2019
Journal of Instrumentation 14(05), P05025 - P05025 (2019). doi:10.1088/1748-0221/14/05/P05025
Analysis of the morphology and composition of tooth apices apicectomized using three different ablation techniques.
2011
Objectives: To investigate apicectomies performed using burs, a CO2 laser or an Er:YAG laser and to evaluate the following aspects: morphology of apicectomized surfaces, presence of failures at the dentin/obturation material interface (marginal fit) of the apical portions of the root canals, and the proportions of chemical elements in the apicectomized surfaces. Study design: Twenty-four teeth were divided into three groups of eight and each group underwent apicectomy by one of three different ablation techniques: bur, CO2 laser or Er:YAG laser. The morphology of the apicectomized surfaces was then analyzed using scanning electron microscopy and their chemical composition was analyzed by en…
Q-switching of an all-fiber ring laser based on in-fiber acousto-optic bandpass modulator2017
2017
Active Q-switching of an all-fiber ring laser utilizing a novel in-fiber acousto-optic tunable bandpass filter (AOTBF) is reported. The transmission characteristics of the AOTBF are controlled by amplitude modulation of the acoustic wave; the device exhibits a 3-dB power insertion loss, 0.91-nm optical bandwidth, and 28-dB nonresonant light suppression. Cavity loss modulation is achieved by full acousto-optic mode re-coupling cycle induced by traveling flexural acoustic waves. When the acoustical signal is switched on, cavity losses are reduced, and then, laser emission is generated. In addition, by varying the acoustic wave frequency, a wide wavelength tuning range of 30.7 nm is achieved f…
Opportunities and limitations of in-gas-cell laser spectroscopy of the heaviest elements with RADRIS
2022
International audience; The radiation detection resonance ionization spectroscopy (RADRIS) technique enables laser spectroscopic investigations of the heaviest elements which are produced in atom-at-a-time quantities from fusion-evaporation reactions. To achieve a high efficiency, laser spectroscopy is performed in a buffer-gas environment used to thermalize and stop the high-energy evaporation residues behind the velocity filter SHIP. The required cyclic measurement procedure in combination with the applied filament collection for neutralization as well as confinement of the stopped ions and subsequent pulse-heat desorption constrains the applicability of the technique. Here, some of these…
Efficacy of 595- and 1319-nm pulsed dye laser in the treatment of acne vulgaris: a narrative review
2020
Acne is one of the commonest problems of adolescence with almost half of the patients experiencing persistence into adulthood. Pulsed dye lasers (PDL) with wavelengths of 585 and 595 nm targeting hemoglobin have been used for the treatment of this condition and its sequelae. Recent introduction of PDL with a higher wavelength of 1319 nm has been reported to offer some benefit to acne patients. We reviewed the literature on the use of 595-nm and 1319-nm PDL in the management of acne. A PubMed literature search for search terms "pulsed dye laser," "acne laser therapy," "light therapy for acne," "595 nm and acne," "1319 nm and acne" was done. Studies, series and case reports were included. The…
Different generators in human temporal-parasylvian cortex account for subdural laser-evoked potentials, auditory-evoked potentials, and event-related…
2000
In order to localize cortical areas mediating pain we now report subdural cortical potentials evoked by auditory stimulation (auditory-evoked potentials - AEPs) and by cutaneous stimulation with a laser (laser-evoked potentials - LEPs). Stimulation with the laser evokes a pure pain sensation by selective activation of nociceptors. LEPs were maximal over the inferior aspect of the central sulcus and had the same polarity on either side of the sylvian fissure. AEPs were maximal posterior to the LEP maximum and had opposite polarity on opposite sides of the sylvian fissure, consistent with the location of a known generator in the temporal operculum. Auditory P3 (event-related) potentials were …
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Changes in Tear Protein Pattern after Photorefractive Keratectomy
2003
PURPOSE. Changes in tear protein composition of patients who underwent photorefractive keratectomy (PRK) were analyzed. METHODS. Tear samples were obtained from 23 eyes of 23 patients immediately before PRK and on the fourth postoperative day with glass capillaries. Tear proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Digital image analysis and evaluation of the densitometric data of the electrophoretic separations were done with BioDoc-Analyze. RESULTS. Analysis of discriminance found a significant difference in the protein patterns (p<0.001). This type of analysis of the electrophoretic densitographs uses all peak information simultaneously. A signifi…