ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
Heavy metal exposure in patients suffering from electromagnetic hypersensitivity
2009
Abstract Background Risks from electromagnetic devices are of considerable concern. Electrohypersensitive (EHS) persons attribute a variety of rather unspecific symptoms to the exposure to electromagnetic fields. The pathophysiology of EHS is unknown and therapy remains a challenge. Objectives Heavy metal load has been discussed as a potential factor in the symptomatology of EHS patients. The main objective of the study was to test the hypothesis of a link between EHS and heavy metal exposure. Methods We measured lead, mercury and cadmium concentrations in the blood of 132 patients ( n = 42 males and n = 90 females) and 101 controls ( n = 34 males and n = 67 females). Results Our result…
Role of Rate Control and Regularization Through Pacing in Patients With Chronic Atrial Fibrillation and Preserved Ventricular Function: The VRR Study
2006
Aim: High heart rates in chronic atrial fibrillation (CAF) is one of the factors responsible for hemodynamic alterations and may lead to tachycardiomyopathies. The ventricular rate regulation (VRR) study evaluates the effect of ventricular rate regularization in CAF patients with preserved ventricular function, marked ventricular rate variability, and indications for pacemaker (PM) implantation owing to symptomatic pauses. Rate regularization was achieved using VRR algorithm (INSIGNIA® pacemakers, Guidant Corp., St. Paul, MN, USA). Methods: One month after PM implantation, 58 patients followed two 3-month crossover periods (VRR-OFF; VRR-ON) in which the VRR algorithm was randomized and comp…
Gender Differences in the Presentation and Outcomes of Hospitalized Patients With COVID-19
2021
Gender-related differences in COVID-19 clinical presentation, disease progression, and mortality have not been adequately explored. We analyzed the clinical profile, presentation, treatments, and outcomes of patients according to gender in the HOPE-COVID-19 International Registry. Among 2,798 enrolled patients, 1,111 were women (39.7%). Male patients had a higher prevalence of cardiovascular risk factors and more comorbidities at baseline. After propensity score matching, 876 men and 876 women were selected. Male patients more often reported fever, whereas female patients more often reported vomiting, diarrhea, and hyposmia/anosmia. Laboratory tests in men presented alterations consistent w…
Gender-dependent behavioural impairment and brain metabolites in young adult rats after short term exposure to lead acetate
2012
We investigated the behavioural effects of short-term lead (Pb) exposure in adult rats producing blood Pb concentration (<10. μg/dL) below those associated with neurological impairment in occupationally exposed individuals. In order to assess gender differences, we performed parallel behavioural experiments in male and female rats. Exposure to Pb acetate (50. mg/L in drinking water) for 30-45 days induced behavioural alterations consisting in hyperactivity in a novel environment and impairment of spatial memory. These effects were observed only in male rats. Object recognition, motor coordination were unaffected by Pb exposure. Magnetic resonance spectroscopy allows . in vivo assessment of …
Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?
1998
UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…
Permanent Pacemaker Lead Insertion Connected to an External Pacemaker Generator for Temporary Pacing After Transcatheter Aortic Valve Implantation.
2019
Abstract Background Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantat…
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…