Search results for "Lens Implantation"

showing 10 items of 140 documents

Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.

2001

To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…

AdultMaleIntraocular pressuremedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIntraocular lensCataractCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansMinimally Invasive Surgical ProceduresProspective StudiesSclerocorneaIntraocular PressureAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsSurgeryScleraOphthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessSurgical incisionScleraJournal of cataract and refractive surgery
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Incidence of posterior vitreous detachment after cataract surgery

2009

Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…

AdultMaleMicrosurgerymedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVitreous DetachmentPosterior vitreous detachmentOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularGermanyOphthalmologymedicineHumansProspective StudiesDioptreAgedUltrasonographyAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industryIncidencePhacoemulsificationMiddle AgedMicrosurgeryCataract surgerymedicine.diseaseeye diseasesSensory SystemsSurgeryVitreous DetachmentOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering

2013

Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …

AdultMaleOptics and PhotonicsPhakic Intraocular LensesVisual acuitymedia_common.quotation_subjectVisual AcuityPupilContrast SensitivityYoung AdultCellular and Molecular NeuroscienceQuality (physics)Lens Implantation IntraocularMyopiamedicineHumansContrast (vision)media_commonImplantable collamer lensbusiness.industryAberrometrySensory SystemsOphthalmologyOptometryFemalemedicine.symptombusinessBritish Journal of Ophthalmology
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up

2014

Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyCiliary sulcusgenetic structuresOne year follow upPolymersVisual AcuityBiocompatible MaterialsPhakic intraocular lensYoung AdultLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesIntraoperative ComplicationsProspective cohort studyDioptreImplantable collamer lensEfficacy indexbusiness.industryCiliary Bodyeye diseasesSensory SystemsPosterior chamber phakic intraocular lensOphthalmologyFemaleSurgeryCollagenbusinessJournal of Cataract and Refractive Surgery
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct