Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration
2007
Purpose To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Setting Ophthalmology Department, Hospital General Universitario, Valencia, Spain. Methods This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postope…
Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.
2011
Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…
One-Year Outcomes with New-Generation Multifocal Intraocular Lenses
2007
Purpose: To compare new-generation multifocal intraocular lenses (IOLs) with monofocal IOLs. Design: Randomized prospective clinical trial. Participants: Sixty-two consecutive patients with cataract, seen between January of 2005 and January of 2006 at the Department of Ophthalmology of Palermo University Hospital in Italy, were bilaterally implanted with monofocal (AR 40, Advanced Medical Optics [AMO], Santa Ana, CA; 15 patients), multifocal refractive (Array SA40N, AMO; 16 patients), multifocal refractive (ReZoom, AMO; 15 patients), or multifocal diffractive pupil-independent (Tecnis ZM900, AMO; 16 patients) IOLs. Intervention: Bimanual phacoemulsification. Main Outcome Measures: Primary o…
Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…
2021
Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…
Retinal straylight in patients with monofocal and multifocal intraocular lenses
2007
Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…
In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.
2015
Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
2012
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.
2016
Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…