Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation

2003

Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…

Malemedicine.medical_specialtymedicine.medical_treatmentAcrylic ResinsLens Capsule CrystallineIntraocular lensPositive correlationCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageLenses IntraocularPhacoemulsificationbusiness.industryCapsulePhacoemulsificationCataract surgeryCapsulorhexisSensory SystemsOphthalmologyCapsular bagFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…

2021

Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…

Medicine (General)medicine.medical_specialtyIntraocular Lens Dislocationgenetic structuresmedicine.medical_treatmentIntraocular lensAfter cataractArticleCataractlate intraocular lens dislocationR5-920Postoperative ComplicationsLens Implantation IntraocularmedicineHumansProspective StudiesProspective cohort studyweak zonules; anterior capsule opening reduction; late intraocular lens dislocation; capsular tension ringReduction (orthopedic surgery)Lenses IntraocularPhacoemulsificationbusiness.industryweak zonulescapsular tension ringGeneral MedicinePhacoemulsificationCataract surgeryLens Subluxationmedicine.diseaseComorbidityeye diseasesSurgeryanterior capsule opening reductionsense organsbusinessMedicina
researchProduct

Retinal straylight in patients with monofocal and multifocal intraocular lenses

2007

Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…

Miosismedicine.medical_specialtyLightPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectIntraocular lensRetinaPupilGlareContrast Sensitivitychemistry.chemical_compoundLens Implantation IntraocularOphthalmologymedicineHumansScattering RadiationContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryGlare (vision)RetinalPhacoemulsificationMiddle AgedMultifocal intraocular lensequipment and supplieseye diseasesSensory SystemsOphthalmologychemistryOptometrySurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering

2012

To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…

Optics and PhotonicsPhakic Intraocular LensesCorneal Wavefront Aberrationgenetic structuresZernike polynomialsComa (optics)In Vitro TechniquesAstigmatismArtificial Lens Implant MigrationProsthesis DesignPhakic intraocular lensRetinasymbols.namesakeOpticsLens Implantation IntraocularmedicineHumansDioptreWavefrontPhysicsbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseeye diseasesRefractive Surgical ProceduresOphthalmologySpherical aberrationAberrations of the eyesymbolsbusinessAmerican Journal of Ophthalmology
researchProduct

Assessing the in vitro optical quality of presbyopic solutions based on the axial modulation transfer function.

2016

Purpose To present a metric for assessing the in vitro optical quality of rotationally symmetrical optical elements based on volume calculation under the surface defined by the axial modulation transfer function (MTF). Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The metric volume under the axial MTF was used to assess the optical quality of 2 rotationally symmetrical multifocal intraocular lenses (IOLs) within various defocus intervals (0.50 diopter [D], 0.75 D, and 1.00 D) and at various spatial frequency intervals (7.5 cycles per degree [cpd], 15.0 cpd, and 30.0 cpd). Results The far focus of the bifocal IOL yielded higher volume values at all spati…

Optics and PhotonicsProsthesis Design01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesDioptreVision OcularMathematicsLenses Intraocularbusiness.industryMultifocal intraocular lensSensory SystemsOptical qualityOphthalmologySpainMetric (mathematics)030221 ophthalmology & optometrySurgeryObjective evaluationSpatial frequencybusinessFocus (optics)Journal of cataract and refractive surgery
researchProduct

Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia

2019

PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…

Optics and PhotonicsRefractive errormedicine.medical_specialtyBiometrymedicine.medical_treatmentIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOptical biometryLens Implantation IntraocularGermanyOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionDioptreRetrospective StudiesMathematicsLenses IntraocularPhacoemulsificationmedicine.diseaseSensory SystemsOphthalmology030221 ophthalmology & optometrySurgeryIntraocular lens power calculationRay tracing (graphics)030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct