Search results for "Lens"

showing 10 items of 948 documents

Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.

2019

Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresContact LensesVisual rehabilitationKeratoconusRefraction Ocularlaw.inventionCorneal hysteresisCorneal Transplantation03 medical and health sciences0302 clinical medicinelawmedicineHumansAgedRetrospective StudiesAged 80 and overKeratometerIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologyEye examination030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryKeratoplasty PenetratingOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes

2019

Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtygenetic structuresContact LensesCorneal StromaKeratoconusEndothelial cell countCorneaProsthesis ImplantationCorneoscleral contact lensCorneal hysteresisTonometry OcularYoung Adult03 medical and health sciences0302 clinical medicineProsthesis FittingCorneaOphthalmologyHumansMedicineProspective StudiesIntracorneal ring segmentIntraocular Pressurebusiness.industryHealthy subjectsProstheses and Implantsmedicine.diseaseElasticityeye diseasesBiomechanical PhenomenaOphthalmologyCross-Sectional Studiesmedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsbusiness030217 neurology & neurosurgeryEye & Contact Lens: Science & Clinical Practice
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye stu…

2007

Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…

AdultMaleLightPsychometricsIntraclass correlationLensletDiagnostic Techniques OphthalmologicalEyeRefraction OcularModels BiologicalSensitivity and SpecificityStandard deviationOpticsmedicineImage Processing Computer-AssistedHumansScattering RadiationMathematicsbusiness.industryObjective measurementCentroidReproducibility of ResultsSmall sampleRepeatabilitySensory SystemsOphthalmologymedicine.anatomical_structureOptometrySurgeryHuman eyeFemalebusinessJournal of cataract and refractive surgery
researchProduct

Israeli Spotted Fever in Sicily. Description of two cases and minireview

2017

Mediterranean spotted fever (MSF) is endemic in Italy, where Rickettsia conorii subsp. conorii was thought to be the only pathogenic rickettsia and Rhipicephalus sanguineus the vector and main reservoir. R. conorii subsp. israelensis, which belongs to the R. conorii complex, is the agent of Israeli spotted fever (ISF); apart from Israel, it has also been found in Italy (Sicily and Sardinia) and in different regions of Portugal. We describe here two severe cases of ISF which occurred in otherwise healthy Italian adults. Their characteristics are analyzed and discussed in the light of other 91 cases found through a systematic review of international literature.

AdultMaleMicrobiology (medical)Settore MED/17 - Malattie InfettiveIsraeli spotted fever; Mediterranean spotted fever; Rickettsia israelensis; Microbiology (medical); Infectious DiseasesRhipicephalus sanguineus030231 tropical medicineBoutonneuse Feverlcsh:Infectious and parasitic diseases03 medical and health sciences0302 clinical medicinemedicineInternational literatureAnimalsHumanslcsh:RC109-216Rickettsia israelensi030212 general & internal medicineIsraelSicilyNormal rangebiologyMediterranean spotted feverGeneral Medicinebiology.organism_classificationmedicine.diseaseIsraeli spotted feverVirologySpotted feverBoutonneuse feverRickettsia conoriiInfectious DiseasesRickettsiaRickettsia israelensisVector (epidemiology)FemaleRickettsia conoriiInternational Journal of Infectious Diseases
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Incidence of posterior vitreous detachment after cataract surgery

2009

Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…

AdultMaleMicrosurgerymedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVitreous DetachmentPosterior vitreous detachmentOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularGermanyOphthalmologymedicineHumansProspective StudiesDioptreAgedUltrasonographyAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industryIncidencePhacoemulsificationMiddle AgedMicrosurgeryCataract surgerymedicine.diseaseeye diseasesSensory SystemsSurgeryVitreous DetachmentOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering

2013

Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …

AdultMaleOptics and PhotonicsPhakic Intraocular LensesVisual acuitymedia_common.quotation_subjectVisual AcuityPupilContrast SensitivityYoung AdultCellular and Molecular NeuroscienceQuality (physics)Lens Implantation IntraocularMyopiamedicineHumansContrast (vision)media_commonImplantable collamer lensbusiness.industryAberrometrySensory SystemsOphthalmologyOptometryFemalemedicine.symptombusinessBritish Journal of Ophthalmology
researchProduct

Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery

2013

To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…

AdultMaleOptics and PhotonicsPhakic Intraocular Lensesmedicine.medical_specialtyCorneal Wavefront AberrationAdolescentgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisPhakic intraocular lensContrast SensitivityYoung AdultLens Implantation IntraocularAberrometryMyopiamedicineHumansIn patientPostoperative PeriodImplantable collamer lensbusiness.industryAberrometryLASIKGeneral Medicineeye diseasesSurgeryOphthalmologySpherical aberrationOptometryFemaleLasers ExcimerbusinessEuropean Journal of Ophthalmology
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct