Search results for "Lens"

showing 10 items of 948 documents

Multifacet structure of observed reconstructed integral images.

2005

Three-dimensional images generated by an integral imaging system suffer from degradations in the form of grid of multiple facets. This multifacet structure breaks the continuity of the observed image and therefore reduces its visual quality. We perform an analysis of this effect and present the guidelines in the design of lenslet imaging parameters for optimization of viewing conditions with respect to the multifacet degradation. We consider the optimization of the system in terms of field of view, observer position and pupil function, lenslet parameters, and type of reconstruction. Numerical tests are presented to verify the theoretical analysis.

Image qualityComputer scienceInformation Storage and RetrievalField of viewIterative reconstructionLensletModels BiologicalSensitivity and SpecificityUser-Computer InterfaceOpticsImaging Three-DimensionalArtificial IntelligencePupil functionImage Interpretation Computer-AssistedComputer GraphicsHumansComputer SimulationIntegral imagingModels Statisticalbusiness.industryReproducibility of ResultsObserver (special relativity)GridImage EnhancementAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisual PerceptionComputer Vision and Pattern RecognitionbusinessAlgorithmsJournal of the Optical Society of America. A, Optics, image science, and vision
researchProduct

Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses

2014

Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…

In line holographyComputer scienceHolographyNormal DistributionBiomedical EngineeringHolographyDiagnostic Techniques OphthalmologicalEngravinglaw.inventionBiomaterialsAutomationImaging Three-DimensionalOpticslawMaterials TestingImage Processing Computer-AssistedHumansComputer visionLensesProgressive addition lensesWavefrontLaser engravingbusiness.industryLasersReproducibility of ResultsEquipment DesignAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisualizationEyeglassesvisual_artCalibrationvisual_art.visual_art_mediumArtificial intelligencebusinessAlgorithmsDigital holographyJournal of Biomedical Optics
researchProduct

Light transmission of the human lens and its relation with aging

2011

Purpose To determine the visible light transmission of the human crystalline lens of persons of different ages, using both solar and incandescent illumination. Methods The spectral transmission of lens was measured by using the Perkin-Elmer 800 UV/VIS spectrophotometer. With these data we calculated the percentage of visible light transmission for solar illumination, simulated by the CIE D65 illuminant, and for incandescent illumination (A illuminant). Results The total amount of visible light transmitted by nine crystalline lenses is represented as a function of age: with solar illumination and with incandescent illumination and the comparison between both illuminants.In general, the amoun…

Incandescent light bulbLight transmissionMaterials sciencebusiness.industryBright-field microscopyStandard illuminantGeneral Medicinelaw.inventionCritical illuminationLens (optics)OphthalmologyOpticsTransmission (telecommunications)lawOptoelectronicssense organsbusinessVisible spectrumActa Ophthalmologica
researchProduct

Age‐induced change in the color of the human crystalline lens

2011

Purpose To determine the chromatic coordinates of different human crystalline lenses to analyze the age-induced change in the color of the crystalline. Methods The spectral transmission of nine human crystalline lenses of different ages were measured by using a Perkin-Elmer 800 UV/VIS spectrophotometer. Using these data we calculated the chromatic coordinates of each crystalline lens for both solar and incandescent illumination. The study adheres to the tenets of the Declaration of Helsinki for Research Including Human Subjects and was approved by the Institutional Review Board. Results The results show a greater saturation of color with the increase of age. In principle, the change tends t…

Incandescent light bulbMaterials sciencebusiness.industrySpectral transmissionGeneral Medicineeye diseaseslaw.inventionLens (optics)OphthalmologyOpticslawTotal transmissionSolar lightsense organsChromatic scalebusinessActa Ophthalmologica
researchProduct

Integral Imaging Monitors with an Enlarged Viewing Angle

2015

Enlarging the horizontal viewing angle is an important feature of integral imaging monitors. Thus far, the horizontal viewing angle has been enlarged in different ways, such as by changing the size of the elemental images or by tilting the lens array in the capture and reconstruction stages. However, these methods are limited by the microlenses used in the capture stage and by the fact that the images obtained cannot be easily projected into different displays. In this study, we upgrade our previously reported method, called SPOC 2.0. In particular, our new approach, which can be called SPOC 2.1, enlarges the viewing angle by increasing the density of the elemental images in the horizontal …

Integral imagingComputer Networks and CommunicationsComputer sciencebusiness.industryThree dimensional displayViewing angleComputational photographyTransformation (function)Feature (computer vision)Media TechnologyComputer visionArtificial intelligenceElectrical and Electronic EngineeringbusinessLens arrayInformation SystemsJournal of information and communication convergence engineering
researchProduct

Optical implementation of micro-zoom arrays for parallel focusing in integral imaging.

2010

We report 3D integral imaging with an electronically tunable-focal-length lens for improved depth of field. The micro-zoom arrays are generated and implemented based on the concept of parallel apodization. To the best of our knowledge, this is the first report of parallel dynamic focusing in integral imaging based on the use of micro-zoom arrays.

Integral imagingbusiness.industryComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage processingAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionLens (optics)OpticsThree dimensional imagingApodizationlawDigital image processingComputer Vision and Pattern RecognitionDepth of fieldZoombusinessJournal of the Optical Society of America. A, Optics, image science, and vision
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Acute endothelial failure after cosmetic iris implants (NewIris®)

2011

We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryCase Reportendothelial failureNewIrisEndothelial cell counteye diseasescosmetic iris implantsSurgeryOphthalmologymedicine.anatomical_structureCorneal edemaIntraocular lensesOphthalmologyDecreased Visual AcuitymedicineImplantsense organsIris (anatomy)businessClinical Ophthalmology (Auckland, N.Z.)
researchProduct

Siderophore typing, a powerful tool for the identification of fluorescent and nonfluorescent Pseudomonas

2002

ABSTRACT A total of 301 strains of fluorescent pseudomonads previously characterized by conventional phenotypic and/or genomic taxonomic methods were analyzed through siderotyping, i.e., by the isoelectrophoretic characterization of their main siderophores and pyoverdines and determination of the pyoverdine-mediated iron uptake specificity of the strains. As a general rule, strains within a well-circumscribed taxonomic group, namely the species Pseudomonas brassicacearum , Pseudomonas fuscovaginae , Pseudomonas jessenii , Pseudomonas mandelii , Pseudomonas monteilii , “ Pseudomonas mosselii ,” “ Pseudomonas palleronii ,” Pseudomonas rhodesiae , “ Pseudomonas salomonii ,” Pseudomonas syringa…

IronStatistics as TopicPseudomonas jesseniiSiderophoresPseudomonas fluorescensPseudomonas thivervalensisPseudomonas fluorescensApplied Microbiology and BiotechnologyFluorescencePseudomonas mosseliiMicrobiology03 medical and health sciencesPseudomonas fuscovaginaeMethodsComputingMilieux_MISCELLANEOUS030304 developmental biology[SDV.EE]Life Sciences [q-bio]/Ecology environment0303 health sciencesEcologybiology030306 microbiologySYDEROPHOREPigments Biologicalbiology.organism_classification[SDV.EE] Life Sciences [q-bio]/Ecology environmentPseudomonas corrugataPseudomonas brassicacearumPseudomonas salomoniiIsoelectric FocusingOligopeptidesFood ScienceBiotechnology
researchProduct

Nonsurgical Procedures for Keratoconus Management

2017

Objectives. To describe the past 20 years’ correction modalities for keratoconus and their visual outcomes and possible complications.Methods. A review of the published literature related to the visual outcomes and possible complications in the context of keratoconus management using nonsurgical procedures for the last 20 years (glasses and contact lenses) was performed. Original articles that reported the outcome of any correction modalities of keratoconus management were reviewed.Results. The most nonsurgical procedure used on keratoconus management is the contact lens fitting. Soft contact lenses and soft toric contact lenses, rigid gas-permeable contact lenses, piggyback contact lens sy…

Keratoconusgenetic structuresPopulationLentes de contactoContext (language use)Review Articlelaw.invention03 medical and health sciences0302 clinical medicinelcsh:OphthalmologylawmedicineOptometríaIn patienteducationeducation.field_of_studyModalitiesbusiness.industrySurgical proceduresmedicine.diseaseeye diseasesContact lensLens (optics)Ophthalmologylcsh:RE1-994030221 ophthalmology & optometryOptometryOftalmologíaÓptica oftálmicasense organsbusiness030217 neurology & neurosurgery
researchProduct