Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation
2003
Purpose: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. Setting: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. Methods: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). Results: The me…
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes
2015
Color perimetry has interesting clinical application for the diagnosis and detection of certain eye conditions, due to the variations that certain diseases can cause in chromatic thresholds, both in the red-green (RG) and the blue-yellow (BY) pathways.[1,2,3,4] The separate study of the visual function of both the chromatic and achromatic mechanisms could be more efficient in detecting sensitivity variations, and such variations would not be obscured by the intrusion of other mechanisms. Currently, the supply of conventional perimeters that are capable of performing a chromatic perimetry test is very limited and with reduced options regarding the possibility of choosing the physical charact…
Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements
2008
PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …
Multipass amplifiers with self-compensation of the thermal lens
2018
We present a novel architecture for a multi-pass amplifier based on a succession of optical Fourier transforms and short propagations that shows a superior stability for variations of the thermal lens compared to state-of-the-art 4f-based amplifiers. We found that the proposed multi-pass amplifier is robust to variations of the active medium dioptric power. The superiority of the proposed architecture is demonstrated by analyzing the variations of the size and divergence of the output beam in form of a Taylor expansion around the design value for variations of the thermal lens in the active medium. The dependence of the output beam divergence and size is investigated also for variations of …
Passive alignment stability and auto-alignment of multipass amplifiers based on Fourier transforms.
2019
The stability properties of Fourier-based multipass amplifier to misalignments (tilts) of its optical components has been investigated. For this purpose, a method to quantify the sensitivity to tilts based on the amplifier small signal gain has been elaborated and compared with measurements. To improve on the tilt stability by more than an order of magnitude a simple auto-alignment system has been proposed and tested. This study, combined with other investigations devoted to the stability of the output beam to variations of aperture and thermal lens effects of the active medium, qualifies the Fourier-based amplifier for the high-energy and the high-power sector.
In vitro power profiles of daily disposable contact lenses
2012
Abstract Purpose To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. Methods The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5 mm to 5.5 mm in steps of 0.5 mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2 mm to 1.0 mm in steps of 0.2…
True and Apparent Oxygen Permeabilities of Contact Lenses
1992
We studied the passage of oxygen through some commercially available contact lenses. Oxygen diffusion coefficients were determined by the time-lag method and a 201T Redher permeometer was used to measure the oxygen permeability and transmissibility by the polarographic method. The measurements were carried out at room temperature with 0.09% sodium chloride physiologic solution. The following types of lenses were tested: (1) 12 lenses of cellulose acetate butyrate (CAB) of a mean thickness of 0.194 mm (observed Dk approximately 6.3 barrers) (1 barrier is equivalent to 10(-11) cm3 of O2 (STP).cm2/cm3.s.mm Hg). (2) 13 lenses of a cross-linked polyhydroxyethyl methacrylate (2-HEMA), manufacture…
Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties.
2003
The instrument oxygen transmissibility (IOT) of organosilicon hydrogels, measured by electrochemical procedures, is 5-10 times larger than that of conventional hydrogels. A method is described that allows the estimation of the oxygen tension at the lens-cornea interface for closed- and open-eyelids situations by combining the IOT of the hydrogels and corneal parameters such as corneal thickness, corneal permeability and oxygen flux across the cornea. From these results the biological oxygen apparent transmissibility (BOAT) is obtained, an important parameter which an multiplication with the pressure of oxygen on the external part of the lens gives the oxygen flux onto the cornea. Contact le…
A swept-current magnetic lens plus Si(Li) electron spectrometer with simultaneous momentum and energy selection
1975
Abstract A combined swept-current magnetic lens plus Si(Li) electron spectrometer with simultaneous momentum and energy selection is presented. The spectrometer is intended for in-beam measurements of conversion electron lines up to several MeV in energy and for nanosecond lifetime determinations, as well as for off-beam studies of continuous beta-ray spectra and conversion lines from short-lived activities. The sweeping of the lens current is automatized and the energy selection, synchronously with the momentum, is performed using a simple digital window arrangement. The performance of the spectrometer is demonstrated in conversion electron and continuous spectrum measurements. Different v…