Search results for "Lenses"

showing 10 items of 294 documents

Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism

1999

Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismRefraction OcularCataractCorneaHigh astigmatismLens Implantation IntraocularOphthalmologyHumansPolymethyl MethacrylateMedicineDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationMiddle AgedCataract surgeryequipment and suppliesmedicine.diseaseeye diseasesSensory SystemsSurgeryToric lensOphthalmologySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of head position on refraction in aphakic and phakic silicone-filled eyes.

1997

BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…

Malemedicine.medical_specialtySupine positionVisual acuitygenetic structuresPseudophakiaPostureVisual AcuityAphakia PostcataractRefraction Ocularchemistry.chemical_compoundSiliconeRefractometerOphthalmologyMedicineHumansSilicone Oilsskin and connective tissue diseasesDioptreLenses Intraocularbusiness.industryRetinal DetachmentGeneral MedicineMiddle AgedRefractioneye diseasesSilicone oilOphthalmologyRefractometrychemistryHead positionFemalesense organsmedicine.symptombusinessHeadRetina (Philadelphia, Pa.)
researchProduct

Intermediate visual function with different multifocal intraocular lens models

2009

Purpose To compare visual acuity at different distances after bilateral implantation of 1 of 4 multifocal intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods This study evaluated consecutive patients who had bilateral implantation of a spherical multifocal IOL with a +4.00 diopter (D) addition (add) (AcrySof ReSTOR SN60D3) or an aspheric multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), +3.75 D add (Acri.LISA 366D), or +3.00 D add (AcrySof ReSTOR SN6AD1). Six months postoperatively, binocular measurement of corrected distance visual acuity (CDVA) at 4 m, corrected near visual acuity (CNVA) at 40 cm, and corrected intermediate visual …

Malemedicine.medical_specialtyVisual acuityDistance visual acuityPseudophakiagenetic structuresVisual AcuityFunctional LateralityContrast SensitivityCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansDioptreAgedLenses IntraocularVision Binocularbusiness.industryDistance PerceptionMiddle AgedMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureVisual functionOptometryFemaleSurgerysense organsmedicine.symptombusinessBinocular visionPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses.

2008

Purpose To compare visual acuity after bilateral implantation of 2 models of multifocal aspheric intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, and University of Valencia, Valencia, Spain. Methods Prospective study of patients who had bilateral implantation of an AcrySof ReSTOR SN6AD3 IOL (Group 1) or an Acri.LISA 366D IOL (Group 2). Six months postoperatively, binocular uncorrected and best corrected distance visual acuity, uncorrected-distance and best distance-corrected near visual acuity, best corrected intermediate visual acuity, and the defocus curve were measured in both IOL groups. Results Group 1 comprised 36 eyes (18 patients) and Group 2, 40…

Malemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresPseudophakiamedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignNear visual acuityFunctional LateralityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesIntermediate visual acuityOptometrySurgeryFemalemedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses

2009

Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …

Malemedicine.medical_specialtyVisual acuityLightPseudophakiagenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityDark AdaptationIntraocular lensCataract ExtractionProsthesis DesignContrast SensitivityLens Implantation IntraocularVision MonocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses Intraocularbusiness.industryPupilCataract surgeryeye diseasesOphthalmologyAlcon LaboratoriesIntraocular lensesOptometryFemalesense organsmedicine.symptombusinessPhotopic visionOphthalmology
researchProduct

Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes

2009

To assess the differences in refractive and visual results obtained in eyes with high and low hyperopia after implantation of a multifocal intraocular lens (IOL).A prospective study was performed on 172 hyperopic eyes implanted with the AcrySof Re-STOR Natural (SN60D3) IOL. Two groups were created, high and low hyperopes (86 eyes in both cases). We analyzed monocular visual acuity for distance and near, with and without distance correction. Photopic and mesopic contrast sensitivity (CS) were also assessed. All measurements were performed at 6 months after surgery.Monocular best distance-corrected visual acuity was 0.01+/-0.03 logMAR for low hyperopes and 0.04+/-0.10 logMAR for high hyperope…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresVisual AcuityProsthesis DesignRefraction Ocular03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyHyperopia030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens

2019

<b><i>Purpose:</i></b> To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). <b><i>Methods:</i></b> Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m<sup>2</sup>), and defocus curve…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignRefraction Ocularlaw.inventionCellular and Molecular NeuroscienceLens Implantation IntraocularlawOphthalmologyHumansMedicineContrast (vision)In patientRetrospective Studiesmedia_commonVision BinocularColor Visionbusiness.industryGeneral MedicinePresbyopiaMiddle Agedmedicine.diseaseMultifocal Intraocular Lenseseye diseasesSensory SystemsLens (optics)OphthalmologyVisual functionFemalemedicine.symptombusinessFollow-Up StudiesPhotopic visionOphthalmic Research
researchProduct

Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study

2012

PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedicine.medical_treatmentVisual AcuityIntraocular lensFirst year of lifeAphakia PostcataractCataract ExtractionAphakiaCataractCataractsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryInfant NewbornInfantArticlesCataract surgerymedicine.diseaseRefractive ErrorsAxial elongationeye diseasesSurgeryContact lensTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up Studies
researchProduct