Search results for "Libration"

showing 10 items of 901 documents

Importance of calibration for diameter and area determination by intravascular ultrasound

1996

Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglas) was performed using a mechanical IVUS system (HP console, 3.5 F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20 degrees C/37 degrees C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20 degrees C there was a constan…

medicine.medical_specialtyObservational errormedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundLumen (anatomy)Coronary VesselsCoronary arteriesCathetermedicine.anatomical_structureCalibrationIntravascular ultrasoundCirculatory systemHumansMedicineRadiology Nuclear Medicine and imagingRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalCardiac imagingBiomedical engineeringThe International Journal of Cardiac Imaging
researchProduct

Development of a Protocol for CCD Calibration: Application to a Multispectral Imaging System

2005

In this paper we describe in detail a method for calibrating a CCD-based camera. The calibration aims to remove both temporal and systematic noises introduced by the sensor, electronics, and optics after which we can correct the non-linearity of its response. For the non-linearity correction we use a simple and powerful approach consisting on a complementary approach between a polynomial fitting and an LUT based algorithm. The proposed methodology is accurate in the sense that it takes into account individual characteristics of each pixel. In each pixel, systematic noises are measured through acquiring offset images, thermal images, and FlatField images. A rigorous protocol for acquiring th…

medicine.medical_specialtyPixelComputer sciencebusiness.industryMultispectral imageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSpectral imagingComputer Science::Computer Vision and Pattern RecognitionmedicineCalibrationComputer visionArtificial intelligencebusinessOptical filterInternational Journal of Robotics and Automation
researchProduct

EPR dosimetry intercomparison using smart phone touch screen glass

2014

International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…

medicine.medical_specialtySmart phoneMass casualty eventStatistics as TopicBiophysicsEPR dosimetry[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]EPR Dosimetry Elecron Paramagnetic Resonance in phone touch screen glass.01 natural sciencesRetrospective dosimetry030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTest material0103 physical sciencesmedicineHumansDosimetryMedical physicsRadiometryGeneral Environmental Science010302 applied physicsRadiationDosimeterbusiness.industryElectron Spin Resonance SpectroscopyRadiological emergencySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Critical levelHomogeneousCalibrationEpr dosimetryGlassbusinessNuclear medicine[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingCell Phone
researchProduct

GEC-ESTRO ACROP recommendations on calibration and traceability of LE-LDR photon-emitting brachytherapy sources at the hospital level

2019

Prostate brachytherapy treatment using permanent implantation of low-energy (LE) low-dose rate (LDR) sources is successfully and widely applied in Europe. In addition, seeds are used in other tumour sites, such as ophthalmic tumours, implanted temporarily. The calibration issues for LE-LDR photon emitting sources are specific and different from other sources used in brachytherapy. In this report, the BRAPHYQS (BRAchytherapy PHYsics Quality assurance System) working group of GEC-ESTRO, has developed the present recommendations to assure harmonized and high-quality seed calibration in European clinics. There are practical aspects for which a clarification/procedure is needed, including aspect…

medicine.medical_specialtyTraceabilityComputer scienceCalibration (statistics)medicine.medical_treatmentBrachytherapyBrachytherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingMedical physicsPhotonsbusiness.industryLE-LDRBrachytherapy; LE-LDR; Seeds; CalibrationHospital levelRadiotherapy DosageHematologyHospitalsOncology030220 oncology & carcinogenesisSeedsCalibrationRadiologi och bildbehandlingbusinessQuality assuranceProstate brachytherapyRadiology Nuclear Medicine and Medical Imaging
researchProduct

Source strength determination in iridium-192 and cobalt-60 brachytherapy : A European survey on the level of agreement between clinical measurements …

2021

Background and purpose: Brachytherapy treatment outcomes depend on the accuracy of the delivered dose distribution, which is proportional to the reference air-kerma rate (RAKR). Current societal recommendations require the medical physicist to compare the measured RAKR values to the manufacturer source calibration certificate. The purpose of this work was to report agreement observed in current clinical practice in the European Union. Materials and methods: A European survey was performed for high- and pulsed-dose-rate (HDR and PDR) highenergy sources (Ir-192 and Co-60), to quantify observed RAKR differences. Medical physicists at eighteen hospitals from eight European countries were contac…

medicine.medical_specialtymedicine.medical_treatmentBrachytherapyTreatment outcomeBrachytherapyR895-920HDRDose distributionMedical physicistMedical physics. Medical radiology. Nuclear medicinePDRmedicinemedia_common.cataloged_instanceRadiology Nuclear Medicine and imagingMedical physicsOriginal Research ArticleEuropean unionRC254-282media_commonRadiationCobalt 60 brachytherapybusiness.industryRAKRNeoplasms. Tumors. Oncology. Including cancer and carcinogensCertificateSource strengthCalibrationRadiologi och bildbehandlingbusinessRAKR; Calibration; HDR; PDR; BrachytherapyRadiology Nuclear Medicine and Medical Imaging
researchProduct

Ultrasound-induced blood clot dissolution without a thrombolytic drug is more effective with lower frequencies.

2004

<i>Background and Purpose:</i> Therapeutic ultrasound as stand-alone therapy or in combination with rt-PA has proven to be an effective measure for recanalisation of acute vessel occlusion in different in vitro and in vivo studies. Uncertainty still exists concerning the optimal frequency and intensity with regard to the thrombolytic efficacy of ultrasound. The purpose of this study was a direct comparison of different ultrasound frequencies, when otherwise using identical measurement settings and parameters. <i>Methods:</i> Ultrasound-induced dissolution of fresh human blood clots was studied in a flow system using low-frequency continuous wave ultrasound of 20, 40 …

medicine.medical_specialtymedicine.medical_treatmentVessel occlusionThrombolytic drugInternal medicinemedicineHumansThrombolytic TherapyUltrasonicsStrokeBlood CoagulationUltrasonographyTherapeutic ultrasoundbusiness.industryUltrasoundAnticoagulantsThrombolysisFrequency dependencemedicine.diseaseRecombinant ProteinsSurgeryBloodNeurologyCalibrationCardiologyNeurology (clinical)Cardiology and Cardiovascular MedicinebusinessCerebrovascular diseases (Basel, Switzerland)
researchProduct

Use of a three-factor interpretive optimisation strategy in the development of an isocratic chromatographic procedure for the screening of diuretics …

2000

Screening of diuretics in urine is feasible through direct injection of the samples into the chromatographic system and isocratic reversed-phase liquid chromatography (RPLC) with micellar-organic mobile phases of sodium dodecyl sulfate (SDS) and 1-propanol. The surfactant coverage of the chromatographic column makes the addition of organic competing amines less necessary than in conventional aqueous-organic RPLC to achieve well-shaped peaks. Also, the range of elution strengths of micellar mobile phases required to elute mixtures of hydrophobic and hydrophilic diuretics is smaller. This allows the isocratic separation of the diuretics within adequate analysis times. An interpretive methodol…

medicine.medical_treatmentBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundmedicineHumansDiureticsMicellesTriamtereneChromatographyChemistryElutionOrganic ChemistryPiretanideGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationMicellar liquid chromatographyCalibrationSpectrophotometry UltravioletXipamideBenzthiazideDiureticmedicine.drugChromatography LiquidJournal of chromatography. A
researchProduct

Methyl Radical in Clathrate Silica Voids. The Peculiar Physisorption Features of the Guest-Host Molecular Dynamics Interaction.

2016

EPR line shape simulations of CH3/SiO2 clathrates and comparison to CH3/N2O and CH3/SiO2 experiments reveal the motional conditions of the CH3 radical up to the unusual regime of its stability, the high-temperature diffusional regime, at 300 K. In the low-temperature region, the CH3 in clathrates is found to rotate around the in-plane axes even at as low temperatures as 3.8 K. However, nonrotating methyls performing only libration about the C2-axes as well as around the C3-axis are also found, proving the existence of special sites in the clathrate voids that begin to accumulate a significant fraction of methyl radicals at temperatures below approximately 7 K. A distinctive feature in the s…

methyl radical CH3 electron paramagnetic resonance spectroscopy EPR clathrate melanophlogiteChemistryRadicalClathrate hydrateMethyl radical02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical scienceslaw.inventionchemistry.chemical_compoundPhysisorptionChemical physicsComputational chemistrylawSpectral widthLibrationPhysical and Theoretical Chemistry0210 nano-technologyAnisotropyElectron paramagnetic resonanceThe journal of physical chemistry. A
researchProduct

Modelling biological nitrogen and phosphorus removal with soluble microbial products (SMP) production-degradation processes

2011

Over the last two decades, Membrane Bioreactors (MBR) are increasingly used for wastewater treatment. Mathematical modelling of MBR systems has played a key role in order to better explain the effect of their peculiarities. Indeed, several MBR models have been presented in literature in order to improve the knowledge on MBR systems: biological models, hybrid models which include soluble microbial product (SMP) modelling, physical models able to describe the membrane fouling and integrated models which couple the hybrid models with the physical ones. However, among the existing MBR models only few integrated models have been developed which take into account the existing relationship between…

model calibrationASM2d-SMPSettore ICAR/03 - Ingegneria Sanitaria-Ambientalemembrane foulingnitrogen phosphorus removalMBR modelling
researchProduct

Comparison of different stochastic models for urban water demand forecasting in drought conditions

2006

models calibration
researchProduct