Search results for "Licata"

showing 10 items of 4432 documents

Proteomics in antitumor research

2006

Proteins are the molecular players of fine-tuned regulatory pathways that underlie the behavior of any cell type. Derangement of this wide protein circuitry has a profound effect on cell life and ultimately contributes to the development of diseases such as cancer. New proteomic technologies are rapidly evolving to define and characterize the nodes of this altered protein network, both inside and outside cancer cells. Hopefully, these technologies will become user-friendly laboratory tools to improve cancer management from early detection to the development of rational and patient-tailored therapeutic strategies.

proteomika; tumori; proteinski čipovi; 2DE; masena spektrometrijaCell typeshotgun approachesCellEarly detectionCancerComputational biologyBiologyProteomicsBioinformaticsmedicine.diseasemedicine.anatomical_structureSettore BIO/13 - Biologia ApplicataDrug DiscoveryCancer managementCancer cellmedicineMolecular MedicineProtein networkClassical gel-base approach
researchProduct

Come predisporre un protocollo per la sorveglianza delle infezioni nei reparti per ustionati

2000

protocollo sorveglianzaustionatiSettore MED/42 - Igiene Generale E Applicata
researchProduct

PRESENZA IN SICILIA DI GLYCASPIS BRIMBLECOMBEI MOORE (Hemiptera Psyllidae) SU EUCALYPTUS CAMALDULENSIS DEHNH..

2011

On the presence in Sicily of Glycaspis brimblecombei Moore (Hemiptera Psyllidae) on Eucalyptus camaldulensis Dehnh. Authors record the occurrence in Sicily of the red gum lerp psyllid, Glycaspis brimblecombei Moore (Hemiptera Psyllidae) attacking Eucalyptus camaldulensis Dehnh. (Myrtaceae). This species, native to Australia, has been first reported for the Palaearctic Region in 2008, when it has been recorded from the Iberian Peninsula. In 2010 it has been found also in Italy. It seems very difficult to control this insect without the diffusion of its specific antagonist Psyllaephagus bliteus Riek (Hymenoptera Encyrtidae), which resulted very effective in its biological control in North Ame…

psylla lerp red gum exotic pestSettore AGR/11 - Entomologia Generale E Applicata
researchProduct

Risultati preliminari di prove svolte in tunnel del vento sull'attrattività di sostanze di origine vegetale nei confronti di Rhynchophorus ferrugineus

2011

punteruolo rosso delle palme repellenza attrattività sostanze di origine vegetaleSettore AGR/11 - Entomologia Generale E Applicata
researchProduct

Il punteruolo delle palme

2010

punteruolo Rhynchophorus ferrugineus palme SiciliaSettore AGR/11 - Entomologia Generale E ApplicataSettore BIO/03 - Botanica Ambientale E Applicata
researchProduct

The quarry waste "Ravaneti" in Sicily: geomorphologic aspect

2009

quarry waste (ravaneti) geomorphology environment geology quarry environment managementSettore GEO/05 - Geologia Applicata
researchProduct

Water Dynamics in Biological Systems investigated using Neutron Scattering Techniques

Living systems can not survive in absence of the water environments which play a fundamental role in living functions. Thus in the scienti?c community many studies were and are addressed to characterize water and its dynamics properties in biological systems. However, a clear description of water in such systems has been not reached yet. In fact, the investigations performed with di?erent techniques - those based on Nuclear Magnetic Resonance or those based on Neutron Scattering - look at di?erent di?usive motions and interactions water-biomolecules, leading controversial results and hence generating many debates between scientists. In this thesis we support the idea that two water populati…

quasi-elastic neutron scattering intracellular water water structure and dynamics bovine brain tissues cellular systems sucrose solutionsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Nuove tecnologie radar per il monitoraggio delle deformazioni superficiali del terreno: casi di studio in Sicilia

2009

radar interferometria differenziale SARSettore GEO/05 - Geologia Applicata
researchProduct

High Bias Voltage CZT Detectors for High-flux Measurements

2017

In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…

radiation detectorRadiology Nuclear Medicine and ImagingMaterials sciencePreamplifier02 engineering and technology01 natural scienceslaw.inventionlawpixel0103 physical sciencesInstrumentationNuclear and High Energy Physic010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleElectrical engineeringBiasing021001 nanoscience & nanotechnologyPhoton countingCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeElectronic Optical and Magnetic MaterialsCZTFull width at half maximumHigh Fluxhigh bias voltageOptoelectronicssemiconductor detector0210 nano-technologybusinessVoltage
researchProduct

Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses

2018

In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…

radiation detectorRadiology Nuclear Medicine and ImagingNuclear and High Energy PhysicsMaterials sciencePreamplifier01 natural sciencesCollimated light030218 nuclear medicine & medical imagingCharge sharinglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical scienceshigh fluxmappingInstrumentation010308 nuclear & particles physicsbusiness.industryASICDetectorBiasingDead timeSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CZTFull width at half maximumsinchrotron radiationbusiness
researchProduct