Search results for "Lier"
showing 10 items of 906 documents
Study of the Planacon XP85012 photomultiplier characteristics for its use in a Cherenkov detector
2016
Main properties of the multi-anode microchannel plate photomultiplier to be used in a Cherenkov detector are discussed. The laboratory test results obtained using irradiation of the MCP-PMT photocathode by picosecond optical laser pulses with different intensities (from single photon regime to the PMT saturation conditions) are presented. peerReviewed
Performance study of the fast timing Cherenkov detector based on a microchannel plate PMT
2017
Prototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.
Verification of Electromagnetic Calorimeter Concept for the HADES spectrometer
2015
The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules…
Test and Simulation of a LYSO+APD matrix with a tagged Photon Beam from 40 to 300 MeV
2012
Understanding the energy resolution terms for LYSO based calorimeters with APD readout at low energy (< 500 MeV) is relevant both for the completion of the KLOE-2 experiment, at DAΦNE, and for the design of the Mu2e calorimeter. In this work, we present a dedicated comparison between experimental data, taken in 2011 at the MAMI tagged photon beam facility with a crystal matrix prototype, and a full Geant-4 simulation of this detector. The crystal prototype matrix consisted of 9 2×2 × 15 cm3 LYSO crystals read-out by 10×10 mm2 Hamamatsu avalanche photodiodes (APD) surrounded by 8 PbWO4 crystals read-out by Bialkali photomultipliers for outer leakage recovery granting a total transverse cover…
Charge radii and electromagnetic moments of At195–211
2018
Hyperfine-structure parameters and isotope shifts of At195-211 have been measured for the first time at CERN-ISOLDE, using the in-source resonance-ionization spectroscopy method. The hyperfine structures of isotopes were recorded using a triad of experimental techniques for monitoring the photo-ion current. The Multi-Reflection Time-of-Flight Mass Spectrometer, in connection with a high-resolution electron multiplier, was used as an ion-counting setup for isotopes that either were affected by strong isobaric contamination or possessed a long half-life; the ISOLDE Faraday cups were used for cases with high-intensity beams; and the Windmill decay station was used for short-lived, predominantl…
Construction, Commissioning and First Results of a Highly Granular Hadron Calorimeter with SiPM-on-Tile Read-out
2018
The CALICE collaboration is developing a highly granular Analogue Hadron sampling CALorimeter (AHCAL) for a future electron-positron collider. Very small detection units are required for the AHCAL due to an optimized design for the Particle Flow Algorithm. This is realized with scintillator tiles each wrapped in reflector foil and individually read out by a silicon photomultiplier (SiPM). These scintillator tiles and SiPMs are assembled on readout boards (HCAL Base Unit, HBU) which are integrated later on in the AHCAL detector stack. With this design a higher energy resolution is achievable, but also a large quantity of components (around 8,000,000 scintillator tiles and SiPMs) are needed t…
Construction of large-area micro-pattern gaseous detectors
2016
Particle physics experiments often comprise tracking detectors with areas of up to a few square meters. If a spatial resolution of the order of 100μm and high-rate capability are required, Micro Pattern Gaseous Detectors (MPGD) are a cost-effective solution. However, the construction of large-area MPGDs is challenging, since tight fabrication tolerances have to be met to guarantee a stable and homogeneous performance. A precision granite table and an automated 3-D positioning system with an attached laser sensor, both inside a laminar-flow cell, have therefore been set up in the PRISMA Detector Lab at Mainz. Currently, this infrastructure is used to produce drift panels for the upgrade of t…
Time Of Flight measurements via two LiDAR systems with SiPM and APD
2016
In this paper, we present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.
Kerman-Onishi conditions in self-consistent tilted-axis-cranking mean-field calculations
2013
\item[Background] For cranked mean-field calculations with arbitrarily oriented rotational frequency vector $\boldsymbol{\omega}$ in the intrinsic frame, one has to employ constraints on average values of the quadrupole-moment tensor, so as to keep the nucleus in the principal-axis reference frame. Kerman and Onishi [Nucl. Phys. A {\bf 361}, 179 (1981)] have shown that the Lagrangian multipliers that correspond to the required constraints are proportional to $\boldsymbol{\omega} \times \boldsymbol{J}$, where $\boldsymbol{J}$ is the average angular momentum vector. \item[Purpose] We study the validity and consequences of the Kerman-Onishi conditions in the context of self-consistent tilted-a…
Performance studies of the P¯ANDA planar GEM-tracking detector in physics simulations
2018
Abstract The P ¯ ANDA experiment will be installed at the future facility for antiproton and ion research (FAIR) in Darmstadt, Germany, to study events from the annihilation of protons and antiprotons. The P ¯ ANDA detectors can cover a wide physics program about baryon spectroscopy and nucleon structure as well as the study of hadrons and hypernuclear physics including the study of excited hyperon states. One very specific feature of most hyperon ground states is the long decay length of several centimeters in the forward direction. The central tracking detectors of the P ¯ ANDA setup are not sufficiently optimized for these long decay lengths. Therefore, using a set of the planar GEM-trac…