Search results for "Linear Model"
showing 10 items of 598 documents
Intraosseous monitoring of drilling in lumbar vertebrae by ultrasound: An experimental feasibility study.
2016
The rationale for this project is to evaluate the efficiency of a novel sonographic method for measurements of interosseous distances. The method utilizes a propagating ultrasonic beam through aqueous milieu which is directed as a jet into a drilled tract. We used a plastic model of human L5 vertebra and ex vivo specimen of L5 porcine vertebra and generated 2 mm in diameter tracts in vertebral pedicles. The tracts were created in the "desired" central direction and in the "wrong" medial and lateral directions. The drilled tracts and the residual, up to opposite cortex, distances were measured sonographically and mechanically and compared statistically. We show that "true" mechanical measure…
Exposure to mercury among 9-year-old Spanish children: Associated factors and trend throughout childhood
2019
Mercury is considered a neurotoxicant and human exposure occurs mainly from the consumption of marine species. We aimed to describe total mercury concentrations (THg) and associated factors in 9-year old children, as well as to explore the trend in THg from 4 to 9 years of age. The study population consisted of 9-year-old children participating in the INMA (Environment and Childhood) birth cohort study in Valencia, Spain (n = 405, 2013–2014). THg in hair samples was measured by atomic absorption spectrometry at the age of 4 and 9 years. Sociodemographic and dietary data was obtained through questionnaires. Multiple linear regression was used to explore the association between THg and covari…
Comparison of the 45-Second/15-Second Intermittent Running Field Test and the Continuous Treadmill Test
2012
Purposes:To compare the physiological responses and maximal aerobic running velocity (MAV) during an incremental intermittent (45-s run/15-s rest) field test (45-15FIT) vs an incremental continuous treadmill test (TR) and to demonstrate that the MAV obtained during 45-15FIT (MAV45-15) was relevant to elicit a high percentage of maximal oxygen uptake (VO2max) during a 30-s/30-s intermittent training session.Methods:Oxygen uptake (VO2), heart rate (HR), and lactate concentration ([La]) were measured in 20 subjects during 2 maximal incremental tests and four 15-min intermittent tests. The time spent above 90% and 95% VO2max (t90% and t95% VO2max, respectively) was determined.Results:Maximal ph…
First-trimester screening for trisomy-21 using a simplified method to assess the presence or absence of the fetal nasal bone.
2005
Objective To determine the benefit of including nasal bone assessment in addition to standard first-trimester markers (nuchal translucency, free beta human chorionic gonadotropin and pregnancy-associated plasma protein A) as a screening test for Down syndrome, using a strict criterion for classification of nasal bone absence. Study design Nasal bone assessment was conducted in 2411 patients with crown-rump length between 45 and 84 mm, including 15 patients with Down syndrome. A patient was considered to have an absent nasal bone only if there was no evidence of present nasal bone. Unlike other studies, nasal bone was classified as present when there was evidence of a thin echogenic line und…
The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.
2011
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…
Nonlinear Modeling of DC/DC Converters Using the Hammerstein's Approach
2007
This paper deals with the modelling of highly nonlinear switching power-electronics converters using black-box identification methods. The duty cycle and the output voltage are chosen, respectively, as the input and the output of the model. A nonlinear Hammerstein-type mathematical model, consisting of a static nonlinearity and a linear time-invariant model, is considered in order to cope with the well-known limitations of the more common small-signal models, i.e. the entity of the variations of the variables around a well-defined steady-state operating point and the incorrect reproduction of the steady-state behavior corresponding to input step variations from the above steady-state operat…
Well-posed nonlinear problems in integrated circuits modeling
1991
In this paper we study the problem (E) + (BC) + (IC) (see below) which represents a model for integrated circuits. We assume that the distributed parametersr(x) andc(x) are nonconstant, dielectric leakages depend on thex-coordinate as well as the voltage level, while the interconnecting multiport is nonlinear and possibly multivalued.
Influence of Concurrent Obesity and Low Birth Weight on Blood Pressure Phenotype in Youth
2009
The aim of this study was to assess the impact of obesity and low birth weight on both office and ambulatory blood pressure (BP) values, as well as on aortic-derived parameters in youths. A total of 422 white youths, from 10 to 18 years of age, were included. Subjects were divided into 4 groups according to the presence (234; 55%) or the absence (188; 45%) of obesity and according to low (114; 27%) or normal (308; 73%, birth weight. Spacelabs 90207 was used to measure ambulatory BP during a 24-hour period. SphygmoCor radial/aortic transform software was used to estimate aortic pressure waveform. Office, 24-hour, daytime, and nighttime systolic BP values were significantly higher in those s…
Predictive value of morphologic parameters for successful correction of Class II Division 2 malocclusion
2003
Abstract The aim of this study was to assess the predictive value of pretreatment cephalometric parameters and apical base size for successful correction of Angle Class II Division 2 malocclusion. Pretreatment lateral cephalograms and pretreatment and posttreatment study casts of 96 subjects with Class II Division 2 malocclusions were examined to obtain 23 cephalometric parameters and to measure the size of the apical bases. Success of occlusal correction was evaluated as the percentage of change of peer assessment rating scores during treatment; percentage of change was the dependent variable in multivariate statistical analyses used to test the predictive value of the assessed parameters.…
Reproducing kernel hilbert spaces regression methods for genomic assisted prediction of quantitative traits.
2008
Abstract Reproducing kernel Hilbert spaces regression procedures for prediction of total genetic value for quantitative traits, which make use of phenotypic and genomic data simultaneously, are discussed from a theoretical perspective. It is argued that a nonparametric treatment may be needed for capturing the multiple and complex interactions potentially arising in whole-genome models, i.e., those based on thousands of single-nucleotide polymorphism (SNP) markers. After a review of reproducing kernel Hilbert spaces regression, it is shown that the statistical specification admits a standard mixed-effects linear model representation, with smoothing parameters treated as variance components.…