Search results for "Liquid nitrogen"
showing 10 items of 31 documents
Impact of a cryogenic baffle system on the suppression of radon-induced background in the KATRIN Pre-Spectrometer
2018
The KATRIN experiment will determine the effective electron anti-neutrino mass with a sensitivity of 200 meV/c2 at 90% CL. The energy analysis of tritium β-decay electrons will be performed by a tandem setup of electrostatic retarding spectrometers which have to be operated at very low background levels of <10−2 counts per second. This benchmark rate can be exceeded by background processes resulting from the emanation of single 219,220Rn atoms from the inner spectrometer surface and an array of non-evaporable getter strips used as main vacuum pump. Here we report on the impact of a cryogenic technique to reduce this radon-induced background in electrostatic spectrometers. It is based on ins…
Efficiency of an on-line isotope separator system employing cooled and NaCl-loaded He-jet methods
1976
Abstract A pure helium-jet at liquid nitrogen temperature coupled to a Nielsen type ion source, and a NaCl-loaded helium-jet coupled to a hollow-cathode ion source have been investigated as means to connect a cyclotron target chamber on-line to a mass separator. Technical details and performances of some critical parts of the system are described. Total separation efficiencies measured under various experimental conditions for several nuclides vary between 0.01 and 1.0%.
Ceramic/metal nanocomposites by lyophilization: Processing and HRTEM study
2012
5 páginas, 8 figuras, 1 tabla.-- El pdf del artículo es el manuscrito de autor.
Comparison between storage of vitrified oocytes by cryotop method in liquid nitrogen vs. vapour phase of liquid nitrogen tanks
2007
Characterization of SiPM properties at liquid nitrogen temperature
2016
SiPM operation at cryogenic temperatures fails for many common devices. A particular type with deep channels in the silicon substrate instead of quenching resistors was thoroughly characterized from room temperature down to liquid nitrogen temperature by illuminating it with low light levels. The devices were mounted in vacuum with the temperature stabilized to allow long-term operation. SiPM signals from a LED pulser were acquired with single-pixel resolution. Generalized fits to the charge collection spectra were used to extract properties like single-pixel gain, inter-pixel variation, breakdown voltage, and photon detection efficiency. With these measurements a deeper investigation of th…
Microscopic observations of superficial ultrastructure of unworn siloxane-hydrogel contact lenses by cryo-scanning electron microscopy
2006
The purpose of this study was to analyze three commercial siloxane-hydrogel contact lens materials, lotrafilcon A, balafilcon A, and galyfilcon A, by cryogenic scanning electron microscopy (cryoSEM). The fully hydrated lenses were frozen in slush liquid nitrogen and qualitatively observed in a cryogenic scanning electron microscope. The superficial ultrastructure of the siloxane-hydrogels was observed at the areas where the lens fractured during sample cryogenic preparation. There are qualitative differences among the three examined materials in the complex polymer network structure existing between the outer layer and the underlying polymer. CryoSEM, although destructive, is a useful tool …
Performance of sensl C-Series SiPM with high photoelectron resolution at cryogenic temperatures
2016
The C-Series of silicon photomultipliers (SiPM) from SensL provides devices with a fast response and high performance at low cost. The device's ability to detect light at temperatures of liquid nitrogen (77K) and liquid helium (4 K) with high photoelectron resolution was demonstrated. Results include relative photon detection efficiency (PDE), gain, microcell capacitance, and cross-talk probability at different over-voltages, both at room and at cryogenic temperatures. At 77K the SiPM demonstrated significantly improved operating characteristics while at 4K the observed increase in break-down voltage, the reduction of PDE by a factor of 2-3, and the extensively dropped microcell capacitance…
A continuous wave 10 W cryogenic fiber amplifier at 1015 nm and frequency quadrupling to 254 nm
2013
A stable, continuous wave, single frequency fiber amplifier system at 1015 nm with 10W output power is presented. It is based on a large mode double clad fiber cooled to liquid nitrogen temperature. The amplified light is frequency quadrupled to 254 nm and used for spectroscopy of the 6^1S - 6^3P transition in mercury.
On the difficulty of assessing the specific surface area of magnesium stearate
2001
Abstract The water content of as-received commercial magnesium stearate batches from animal and vegetable sources have been modified by ageing in humid air at room temperature or by vacuum treatment. The complete adsorption–desorption isotherms of nitrogen and krypton vapours by samples of these as received and modified materials have been measured at liquid nitrogen temperature after standardised vacuum degassing. They are greatly affected by the initial water content of the material. In particular: (a) the BET surface area values computed from the adsorption branch vary widely and is increasing with increasing water content; (b) anomalous hysteresis of varying amplitude is observed in all…
Transient and Steady-State Radiation Response of Phosphosilicate Optical Fibers: Influence of H2 Loading
2019
The radiation response of a phosphorus-doped multimode optical fiber is investigated under both transient (pulsed X-rays) and steady-state ( $\gamma $ - and X-rays) irradiations. The influence of a H2 preloading on the fiber radiation-induced attenuation (RIA) in the 300–2000-nm wavelength range has been characterized. To better understand the impact of this treatment, online behaviors of fiber samples containing different amounts of gas are compared from glass saturation (100%) to less than 1%. In addition to these in situ experiments, additional postirradiation spectroscopic techniques have been performed such as electron paramagnetic resonance or luminescence measurements to identify the…