Search results for "MAS"

showing 10 items of 18047 documents

Optimization of a laser ion source for $^{163}$Ho isotope separation

2019

To measure the mass of the electron neutrino, the “Electron Capture in Holmium-163” (ECHo) collaboration aims at calorimetrically measuring the spectrum following electron capture in 163Ho. The success of the ECHo experiment depends critically on the radiochemical purity of the 163Ho sample, which is ion-implanted into the calorimeters. For this, a 30 kV high transmission magnetic mass separator equipped with a resonance ionization laser ion source is used. To meet the ECHo requirements, the ion source unit was optimized with respect to its thermal characteristics and material composition by means of the finite element method thermal-electric calculations and chemical equilibrium simulation…

010302 applied physicsMaterials sciencePhysics - Instrumentation and DetectorsAtomic Physics (physics.atom-ph)Electron captureFOS: Physical sciencesThermal ionizationInstrumentation and Detectors (physics.ins-det)Laser01 natural sciencesIon source010305 fluids & plasmasIsotope separationlaw.inventionPhysics - Atomic PhysicslawIonization0103 physical sciencesThermalAtomic physicsChemical equilibriumInstrumentation
researchProduct

Quartz resonators for penning traps toward mass spectrometry on the heaviest ions

2020

We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…

010302 applied physicsMaterials scienceSidebandCyclotronMass spectrometry01 natural sciences7. Clean energyAtomic mass010305 fluids & plasmaslaw.inventionIonCrystalResonatorPhysics::Plasma Physicslaw0103 physical sciencesAtomic physicsddc:620InstrumentationQuartz
researchProduct

Fluence effect on ion-implanted As diffusion in relaxed SiGe

2005

A systematic study on the fluence (5 × 108 − 4 × 1014 cm−2) dependence of ion-implanted As diffusion in relaxed Si1 − xGex alloys (with x = 0.2, 0.35 and 0.5) and silicon has been performed by the modified radiotracer and secondary ion mass spectrometry techniques. With fluences above 4 × 1011 cm−2 a clear fluence-dependent enhancement in arsenic diffusion was noted for Si1 − xGex. In case of arsenic-implanted silicon such fluence dependency was not observed. This can be assigned to enhanced implantation-induced damage formation and more deficient radiation damage recovery of SiGe.

010302 applied physicsMaterials scienceSiliconAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_element02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesFluenceIonSecondary ion mass spectrometrychemistry0103 physical sciencesRadiation damageDiffusion (business)0210 nano-technologyArsenicEurophysics Letters
researchProduct

HCl gas gettering of low-cost silicon

2013

HCl gas gettering is a cheap and simple technique to reduce transition metal concentrations in silicon. It is attractive especially for low-cost silicon materials like upgraded metallurgical grade (UMG) silicon, which usually contain 3d transition metals in high concentrations. Etching of silicon by HCl gas occurs during HCl gas gettering above a certain onset temperature. The etching rate as well as the gettering efficiency was experimentally determined as a function of the gettering temperature, using UMG silicon wafers. The activation energy of the etching reaction by HCl gas was calculated from the obtained data. The gettering efficiency was determined by analyzing Ni as a representativ…

010302 applied physicsMaterials scienceSiliconEtching rateInorganic chemistrychemistry.chemical_element02 engineering and technologySurfaces and InterfacesActivation energy021001 nanoscience & nanotechnologyCondensed Matter Physics7. Clean energy01 natural sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialschemistryTransition metalGetterEtching (microfabrication)0103 physical sciencesMaterials ChemistryWaferElectrical and Electronic Engineering0210 nano-technologyInductively coupled plasma mass spectrometryphysica status solidi (a)
researchProduct

XUV diagnostic to monitor H-like emission from B, C, N, and O for the W7-X stellarator

2019

The “C/O Monitor” system for the Wendelstein 7-X (W7-X) stellarator is a dedicated spectrometer with high throughput and high time resolution (order of 1 ms) for fast monitoring of content of low-Z impurities in the plasma. The observed spectral lines are fixed to Lyman-α lines of H-like atoms of carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm), and boron (4.9 nm). The quality of the wall condition will be monitored by the measurements of oxygen being released from the walls during the experiments. The strong presence of carbon is an indication for enhanced plasma-wall interaction or overload of plasma facing components. The presence of nitrogen (together with oxygen) may indicate a poss…

010302 applied physicsMaterials scienceSpectrometerAnalytical chemistrychemistry.chemical_element01 natural sciencesNitrogenOxygenSpectral line010305 fluids & plasmaslaw.inventionchemistryImpuritylaw0103 physical sciencesPlasma diagnosticsBoronInstrumentationStellarator
researchProduct

Choice of the detectors for light impurities plasma studies at W7-X using ‘CO Monitor’ system

2019

Abstarct The ‘CO Monitor’ is a new spectrometer system dedicated for the continuous measurements of line intensities of carbon, oxygen, boron and nitrogen at the fusion plasma experiment Wendelstein 7-X (W7-X). Its main purpose is to deliver constant information about indicated elements with high time resolution (better than 1 ms), but low spatial resolution since the line shapes are not going to be investigated. The system consists of four independent channels, each equipped with dispersive element dedicated for measurement of selected line of interest. In order to perform the highest efficiency of the ‘CO Monitor’ system, it is essential to choose the proper detector type for this task. T…

010302 applied physicsMaterials scienceSpectrometerbusiness.industryMechanical EngineeringDetectorPhase (waves)PlasmaElectronXUVDetectorsWendelstein 7-XStellarator01 natural sciencesLine (electrical engineering)010305 fluids & plasmasOpticsNuclear Energy and Engineering0103 physical sciencesGeneral Materials SciencebusinessSensitivity (electronics)Image resolutionCivil and Structural EngineeringFusion Engineering and Design
researchProduct

Correlations between density distributions, optical spectra, and ion species in a hydrogen plasma (invited)

2016

An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H + , H + 2 , and H + 3 ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical facto…

010302 applied physicsMaterials scienceWien filterta114Hydrogenchemistry.chemical_elemention speciesPlasma01 natural sciences010305 fluids & plasmasIonchemistryPhysics::Plasma Physics0103 physical scienceshydrogen plasmaMass spectrumPlasma diagnosticsEmission spectrumAtomic physicsdensity distributionsoptical spectraInstrumentationVisible spectrumReview of Scientific Instruments
researchProduct

Plasma instabilities of a charge breeder ECRIS

2017

International audience; Experimental observation of plasma instabilities in a charge breeder electron cyclotron resonance ion source (CB-ECRIS) is reported. It is demonstrated that the injection of 133Cs+ or 85Rb+ ion beam into the oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which restricts the parameter space available for the optimization of the charge breeding efficiency. It is concluded that the transition from a stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb and simultaneous change of the discharge parameters in 10–100 ms time scale, not by a prompt interaction between the incident ion beam and the ECRIS pla…

010302 applied physicsMaterials science[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Charge (physics)Plasmaplasma instabilitiescharge breederCondensed Matter Physics01 natural sciences010305 fluids & plasmasNuclear physicsBreeder (animal)Physics::Plasma Physics0103 physical sciences
researchProduct

The role of seed electrons on the plasma breakdown and preglow of electron cyclotron resonance ion source

2009

The 14 GHz Electron Cyclotron Resonance Ion Source at University of Jyväskylä, Department of Physics (JYFL) has been operated in pulsed mode in order to study the plasma breakdown and preglow effect. It was observed that the plasma breakdown time and preglow characteristics are affected by seed electrons provided by a continuous low power microwave signal at secondary frequency. Sustaining low density plasma during the off-period of high power microwave pulses at the primary frequency shifts the charge state distribution of the preglow transient toward higher charge states. This could be exploited for applications requiring fast and efficient ionization of radioactive elements as proposed f…

010302 applied physicsMaterials science[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonancechemistry.chemical_elementPlasmaElectron01 natural sciences7. Clean energyElectron cyclotron resonanceIon source010305 fluids & plasmasNeonchemistryIonizationBeta (plasma physics)0103 physical sciencesAtomic physicsInstrumentationComputingMilieux_MISCELLANEOUSReview of Scientific Instruments
researchProduct

A new Collinear Apparatus for Laser Spectroscopy and Applied Science (COALA).

2020

We present a new collinear laser spectroscopy setup that has been designed to overcome systematic uncertainty limits arising from high-voltage and frequency measurements, beam superposition, and collisions with residual gas that are present in other installations utilizing this technique. The applied methods and experimental realizations are described, including an active stabilization of the ion-source potential, new types of ion sources that have not been used for collinear laser spectroscopy so far, dedicated installations for pump-and-probe measurements, and a versatile laser system referenced to a frequency comb. The advanced setup enables us to routinely determine transition frequenci…

010302 applied physicsMaterials sciencebusiness.industryLaserResidual01 natural sciences010305 fluids & plasmasIonlaw.inventionMetrologyFrequency combSuperposition principleOpticslaw0103 physical sciencesSpectroscopybusinessInstrumentationBeam (structure)The Review of scientific instruments
researchProduct