Headspace–mass spectrometry determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers in soil samples using chemometrics

2007

A simple and fast method has been developed for the determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers (BTEX) in soils. Samples were introduced in 10 mL standard glass vials of a headspace (HS) autosampler together with 150 microL of 2,6,10,14-tetramethylpentadecane, heated at 90 degrees C for 10 min and introduced in the mass spectrometer by using a transfer line heated at 250 degrees C as interface. The volatile fraction of samples was directly introduced into the source of the mass spectrometer which was scanned from m/z 75 to 110. A partial least squares (PLS) multivariate calibration approach based on a classical 3(3) calibration model was build with m…

Analytical chemistryBTEXXylenesMass spectrometryBiochemistryEthylbenzeneGas Chromatography-Mass SpectrometryMass SpectrometryAnalytical ChemistryChemometricsSoilchemistry.chemical_compoundIsomerismBenzene DerivativesEnvironmental ChemistryBenzeneSpectroscopyChromatographyChromatographyXyleneTemperatureBenzeneTolueneHydrocarbonsBiodegradation EnvironmentalModels ChemicalchemistryCalibrationGas chromatographyTolueneAnalytica Chimica Acta
researchProduct

X-ray analysis on the nanogram to microgram scale using porous complexes

2012

X-ray single-crystal diffraction (SCD) analysis has the intrinsic limitation that the target molecules must be obtained as single crystals. Here we report a protocol for SCD analysis that does not require the crystallization of the sample. In our method, tiny crystals of porous complexes are soaked in a solution of the target, such that the complexes can absorb the target molecules. Crystallographic analysis clearly determines the absorbed guest structures along with the host frameworks. Because the SCD analysis is carried out on only one tiny crystal of the complex, the required sample mass is of the nanogram–microgram order. We demonstrate that as little as about 80 nanograms of a sample …

Analytical chemistryCrystallography X-RayMass spectrometryHigh-performance liquid chromatographyAbsorptionlaw.inventionCrystallawAnimalsNanotechnologyMoleculeCrystallizationta116Biological ProductsMultidisciplinaryChemistryMicrochemistryAnalytic Sample Preparation MethodsPoriferaCharacterization (materials science)AlkynesFatty AlcoholsAbsorption (chemistry)CrystallizationPorous mediumPorosityNature
researchProduct

Low vacuum photo electron emitting thin films

2009

Impact ionisation is a standard procedure to ionise gaseous or vaporisable substances in organic mass spectrometry. In this work, a "softer" ionisation is introduced which seems to be an alternative ion source for reducing collision between substance molecules and the hot internal walls of the box. Through collision mainly found in impact ionisation sources, fragments are built especially from thermally sensitive substances falsifying the spectra. We present here photoelectron emitting materials for the soft ionisation using semiconducting compounds, galliumn nitride (GaN), and a representative of the borides, lanthanum hexaboride (LaB 6 ). They are evaluated by photoelectron spectroscopic …

Analytical chemistryGallium nitrideSurfaces and InterfacesElectronLanthanum hexaborideNitrideCondensed Matter PhysicsMass spectrometryIon sourceSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry.chemical_compoundchemistryIonizationMaterials ChemistryElectrical and Electronic EngineeringThin filmphysica status solidi (a)
researchProduct

Optical saturation thermal lens spectrometry in non-polar solvents

1997

Abstract A model for thermal lens spectrometry (TLS) in partial optical saturation conditions which was previously applied to polar solutes in aqueous media is now checked with non-polar organic dyes and metal dithizonates in carbon tetrachloride. Some literature data are also examined. Most data can be consistently explained on the basis of the molecular structures, the sensitivity increasing with the capability of the solute to rapidly communicate the absorbed energy to the solvent molecules.

Analytical chemistryMass spectrometryBiochemistryAnalytical ChemistrySolventMetalchemistry.chemical_compoundchemistryvisual_artThermalCarbon tetrachloridevisual_art.visual_art_mediumEnvironmental ChemistryPolarMoleculeSaturation (chemistry)SpectroscopyAnalytica Chimica Acta
researchProduct

Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in …

2012

Abstract Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP ® ) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap ® ). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP ® instrument ranged …

Analytical chemistryMass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical ChemistryIonlaw.inventionBaby foodchemistry.chemical_compoundlawLimit of DetectionMSPDHumansQuadrupole ion trapMycotoxinQTRAPChromatography High Pressure LiquidChromatographyBaby foodOrganic ChemistryInfantGeneral MedicineMycotoxinsOrbitrapchemistryQuadrupoleInfant FoodJournal of chromatography. A
researchProduct

Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…

2014

An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…

Analytical chemistryTandem mass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionMatrix (chemical analysis)Gel permeation chromatographychemistry.chemical_compoundColumn chromatographylawTandem Mass SpectrometryAnimalsMuscle SkeletalChromatography High Pressure LiquidHexabromocyclododecaneChromatographyEelsOrganic ChemistryFishesReproducibility of ResultsGeneral MedicineRepeatabilityTriple quadrupole mass spectrometerHydrocarbons BrominatedchemistryWater Pollutants ChemicalEnvironmental MonitoringJournal of chromatography. A
researchProduct

FT-ICR MS studies of ion-molecule reactions of Ru+ and Os+ with oxygen

2005

Abstract The reactions of stored ruthenium and osmium cations with oxygen have been studied in a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. In case of osmium the reaction products OsO+ and OsO 2 + have been observed and corresponding reaction-rate constants have been determined. In addition, there is an unreactive fraction of Os+ ions due to the presence of a slightly endothermic reacting ground state. Only the excited states react with oxygen. For ruthenium no spontaneous reaction with oxygen has been observed unless the cyclotron motion of Ru+ was excited. The results are discussed with respect to a similar investigation in a Penning trap-TOF mass spectrometer […

Analytical chemistrychemistry.chemical_elementCondensed Matter PhysicsMass spectrometryOxygenFourier transform ion cyclotron resonanceHassiumRutheniumIonchemistryExcited stateOsmiumPhysical and Theoretical ChemistryInstrumentationSpectroscopyInternational Journal of Mass Spectrometry
researchProduct

Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…

2015

A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…

Analytical chemistrychemistry.chemical_elementNatural GasMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeLimit of DetectionEnvironmental ChemistryBenzeneSpectroscopyDetection limitAir PollutantsZeeman effectSpectrometerSpectrophotometry AtomicAbsorption RadiationBenzeneEquipment DesignTolueneMercury (element)WavelengthMercury IsotopeschemistrysymbolsEnvironmental MonitoringAnalytica chimica acta
researchProduct

Investigation on sol–gel synthesized Ag-doped TiO2 cermet thin films

2005

Abstract Undoped TiO 2 and Ag–TiO 2 (up to 23 at.% Ag) cermet thin films and polycrystalline powders have been prepared by sol–gel process. Their structure, composition, surface morphology and optical properties have been investigated by X-ray diffraction (XRD), differential thermal analysis (DTA), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), secondary ion mass spectrometry (SIMS) and ultraviolet–visible spectroscopy (UV–VIS spectroscopy). It has been observed that while Ag does not form a solid solution with TiO 2 , it promotes the anatase to rutile phase transformation. The transformation temperature decreases from 827 °C for undoped TiO 2 to about 650 °C fo…

AnataseMaterials scienceScanning electron microscopeMetals and AlloysAnalytical chemistrySurfaces and InterfacesCermetSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsSecondary ion mass spectrometryX-ray photoelectron spectroscopyDifferential thermal analysisMaterials ChemistryCrystalliteSol-gelThin Solid Films
researchProduct

First isomeric yield ratio measurements by direct ion counting and implications for the angular momentum of the primary fission fragments

2018

We report the first experimental determination of independent isomeric yield ratios using direct ion counting with a Penning trap, which offered such a high resolution in mass that isomeric states could be separated. The measurements were performed at the Ion Guide Isotope Separator On-Line (IGISOL) facility at the University of Jyvaskyla. The isomer production ratios of Ge-81, Y-96,Y-97 Sn-128(,1)30, and Sb-129 in the 25-MeV proton-induced fission of U-na(t) and Th-232 were studied. Three isomeric pairs (Ge-81, Y-96, and Sb-129) were measured for the first time for the U-na(t)(p, f) reaction, while all the reported yield ratios for the Th-232(p, f) reaction were determined for the first ti…

Angular momentumResolution (mass spectrometry)Fission01 natural sciencesIonSubatomär fysikydinreaktiotPrimary (astronomy)0103 physical sciencesSubatomic PhysicsPhysics::Atomic and Molecular ClustersfissionYield ratioPhysics::Atomic PhysicsPhysics::Chemical PhysicsNuclear Experiment010306 general physicsnuclear reactionsPhysicsta114010308 nuclear & particles physicsPenning trapfissioYield (chemistry)Atomic physicsisomer decaysydinfysiikka