Search results for "MEASUREMENTS"
showing 10 items of 720 documents
"Table 15b" of "Ground and excited charmonium state production in p+p collisions at sqrt(s)=200 GeV"
2023
$J/\psi$ counts obtained from the dimuon decay analysis of four different data sets, determined using the fit function. The S and N following 2006 and 2008 indicate the data sets for the south and north forward arms.
"Table 6a" of "Ground and excited charmonium state production in p+p collisions at sqrt(s)=200 GeV"
2023
$\psi^{\prime}(J/\psi)$ dielectron yield ratio measured at $|y|$ < 0.35 followed by point-to-point uncorrelated (uncorr.) (statistical and uncorrelated systematic uncertainties) and correlated systematic (corr.) uncertainties.
"Figure 21" of "Ground and excited charmonium state production in p+p collisions at sqrt(s)=200 GeV"
2023
Rapidity dependence of the $J/\psi$ yield combining dielectron ($|y|$ < 0.35 - full squares) with dimuon channels (1.2 < $|y|$ < 2.4 - full circles) along with the fits used to estimate the total cross section. Uncertainties are point-to-point uncorrelated (uncorr.) (statistical and uncorrelated systematic uncertainties) and correlated systematic (corr.) uncertainties. The global uncertainty is 10%.
"Figure 8a" of "Ground and excited charmonium state production in p+p collisions at sqrt(s)=200 GeV"
2023
Transverse momentum dependence of $J/\psi$ and $\psi^{\prime}$ yields in $|y|$ < 0.35, and ${\psi^{\prime}}/{J/\psi}$ ratio together with ratios obtained in other experiments. Uncertainties are point-to-point uncorrelated (uncorr.) (statistical and uncorrelated systematic uncertainties) and correlated systematic (corr.) uncertainties. The global uncertainty is 10%.
Deducing the stage-discharge relationship for contracted weirs by the outflow theory of Malcherek
2019
The aim of this paper was the deduction of a new stage-discharge relationship for a contracted weir, having a crest length less than the channel width, by using the Malcherek’s outflow theory. The average outflow velocity over the rectangular contracted weir was expressed in terms of the head over weir, the momentum correction coefficient and the ratio between the crest length and the channel width. This theoretically deduced stage-discharge formula was calibrated by measurements carried out for values of the ratio between the crest length and the channel width ranging from 0.3125 to 0.9375. In particular, a relationship to estimate the momentum correction coefficient for contracted weirs w…
Characterization of the Magnetic Induction Field produced by Secondary Substations
2014
The aim of this paper is to develop a methodology for measuring the magnetic field distribution around the prefabricated secondary substations in vibrated reinforced concrete, as well as the definition of a methodology to determining the maximum value of magnetic induction produced by the substations in correspondence to nominal current of the transformer. As proposed has been developed in conformity with laws and standards and can be applied to active and passive secondary substations. The experimental validation of the proposed methodology, carried out by a measurements campaign whose results are reported, confirms the validity and returns a versatile and simple tool for the verification …
Earth resistance measurements in urban contexts: Problems and possible solutions
2017
Both EN 50522 and IEEE Std. 81 propose the Fall of Potential Method (FPM) to carry out the measurement of the resistance to earth of an Earthing System (ES). However, in urban areas, the recommended distances between the ES and auxiliary electrodes are not easy to respect, due to the presence of buildings and tarmac. Moreover, unknown buried metallic parts, as well as the interconnection among the ESs made by the Distributor System Operator, could modify the earth potential profile of the area, affecting the measurement results. In this paper, the issues that could affect the measurement result if FPM is used in an urban context are presented. A parametric analysis, carried out with Comsol …
The TRAPSENSOR facility: an open-ring 7 tesla Penning trap for laserbased precision experiments
2019
APenning-trap facility for high-precision mass spectrometry based on a novel detection method has been built. This method consists in measuring motional frequencies of singly-charged ions trapped in strong magnetic fields through the fluorescence photons from laser-cooled 40Ca+ ions, to overcome limitations faced in electronic single-ion detection techniques. The key element of this facility is an open-ring Penning trap coupled upstream to a preparation Penning trap similar to those used at Radioactive Ion Beam facilities. Here we present a full characterization of the trap and demonstrate motional frequency measurements of trapped ions stored by applying external radiofrequency fields in r…
Magnetic transition metal complexes of tetrathiafulvalene (TTF) derivatives
1997
We have prepared and characterized the transition metal complexes of two different TTF derivatives. We have oxidized the different complexes with electrooxidation and chemical oxidation techniques and the results are discussed. The magnetic properties of the complexes have been studied. TTF-carboxylate chelates are not stable enough, but thioether-TTF shows promising charge transfer salts.
Comparison of condensed versus noncondensed cycling test methods and correlation to a 185 minutes’ indoor race simulation
2017
Master's thesis Sports Science ME517 - University of Agder 2017 Background: The validity of a currently used condensed indoor test protocols (C-TP) as measurement of competitive cycling performance is questioned. Purpose: C-TP contain testing of wattage at lactate threshold (LTW), maximum oxygen consumption (VO2max) and a Wingate anaerobic test (WAnT), performed consecutively during one session. As comparison these tests were separated and performed individually over three consecutive days, giving a non-condensed test protocol (NC-TP). The results were compared to a 5min all-out cycling test (5min all-out) performed individually and as part of a 185 minutes’ race simulation. Method: During …