Search results for "MPL"
showing 10 items of 21777 documents
Impact of the erase algorithms on flash memory lifetime
2017
This paper presents a comparative study on the impact of the erase algorithm on flash memory lifetime, to demonstrate how the reduction of overall stress, suffered by memories, will increase their lifetime, thanks to a smart management of erase operations. To this purpose a fixed erase voltage, equal to the maximum value and the maximum time-window, was taken as the reference test; while an algorithm with adaptive voltage levels and the same overall time-window was designed and implemented in order to compare their experimental results. This study was carried out by using an innovative Automated Test Equipment, named Portable-ATE, tailored for Memory Test Chip and designed for performance e…
FPGA based digital lock-in amplifier for fNIRS systems
2018
Lock-In Amplifiers (LIA) represent a powerful technique helping to improve signals detectability when low signal to noise ratios are experienced. Continuous Wave functional Near Infrared Spectroscopy (CW-fNIRS) systems for e-health applications usually suffer of poor detection due to the presence of strong attenuations of the optical recovering path and therefore small signals are severely dipped in a high noise floor. In this work a digital LIA system, implemented on a Zynq® Field Programmable Gate Array (FPGA), has been designed and tested to verify the quality of the developed solution, when applied in fNIRS systems. Experimental results have shown the goodness of the proposed solutions.
Custom measurement system for memristor characterisation
2021
Abstract A cheap, compact and customisable characterisation system for memristor devices, working between ± 10 V, is presented. SPICE (Simulation Program with Integrated Circuit Emphasis) simulations are performed to verify the circuit feasibility and a proper software is developed to drive the system. The potentiality of the realised system is tested by performing several electrical measurements on both Cu/HfO2/Pt memristors and two-terminals commercial devices.
Pulsed Electro-Acoustic Method for specimens and cables employed in HVDC systems: Some feasibility considerations
2018
Recent experiments on the use of the PEA method for testing dielectric materials in specimens and comparison with a detailed model provide an insight of the phenomenon and suggest the need of adopting similar models also for cables. What is said is even more important considering the possible future adoption of the PEA methodology to test DC cables for Pre-Qualification and Type Tests. The use of an accurate model of the PEA cell used for testing specimens and related experiments prove that the thickness of the different parts composing the PEA setup is a basic element for providing accurate charge reading and interpretation of the phenomenon. Both simulation and experimental results, carri…
High-Power Multicarrier Generation for RF Breakdown Testing
2017
Testing of satellite components for high RF power breakdown effects, such as multipactor and corona or passive-intermodulation, is a topic of growing interest in the aerospaceindustry. Switching fromthe classical single carrier approach to the more realisticmulticarrier scenario is very challenging from the experimental point of view. Themulticarrier signals, amplifiedby several RF power amplifiers, need to have controlled phase, amplitude, and frequency in each carrier. Fine tuning of the signal generator phases is required in order to compensate the phase drift occurring in the active elements of the test bed. This paper presents an efficient and low-cost technique to generate multicarrie…
Laser Ultrasonics Inspection for Defect Evaluation on Train Wheel
2019
Abstract Passengers’ safety and in-service life of wheelset axles play an important role in railway vehicles. For this reason, periodic inspections are necessary. Among non-destructive techniques, ultrasonic ones are widely applied in this field. The main disadvantage of conventional ultrasonic techniques is that the overall inspection of wheels requires the train to be put out-of-service and disassembly each part, which is time-consuming and expensive. In this paper, a non-conventional non-contact laser ultrasonic inspection for train wheels is proposed. The proposed method uses a laser interferometer to receive the ultrasonic wave without contact. The receiving system allows choosing the …
A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions
2019
Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…
Power efficiency improvements with the radio frequency H− ion source
2016
CW 13.56 MHz radio frequency-driven H(-) ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H(-) beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation …
Annealing behaviour of aluminium-implanted InP
2000
The annealing behaviour of aluminium has been studied in single-crystal InP implanted with 40 and 120 keV 27Al+ ions. The implantation doses were 1 x 1015 and 1 x 1016 cm-2. The aluminium concentration profiles were determined by two techniques, Secondary ion mass spectrometry (SIMS) and the nuclear resonance broadening technique (NRB) which was used for checking purposes. The usability of the SIMS technique for profiling Al rich layers was studied. Significant inconsistencies were observed in the SIMS profiles with the high dose implanted samples. The 120 keV, 1 x 1016 cm-2 implanted samples were subject to annealing in argon atmosphere in the temperature range 380–600°C. Redistribution an…
The peculiarities of the radiation damage accumulation kinetics in the case of defect complex formation
2020
Abstract The kinetics of radiation defect accumulation under irradiation by heavy particles is theoretically analysed under the assumption of defect complex genesis, particularly, the ones of anion and cation vacancies. The obtained analytical mathematical model and revealed peculiarities of radiation dose dependencies can be used for analysis of the experimental results for different crystalline materials for solid-state electronics and photonics.