Search results for "MRI"

showing 10 items of 733 documents

Synergetic and redundant information flow detected by unnormalized Granger causality: application to resting state fMRI

2015

Objectives: We develop a framework for the analysis of synergy and redundancy in the pattern of information flow between subsystems of a complex network. Methods: The presence of redundancy and/or synergy in multivariate time series data renders difficult to estimate the neat flow of information from each driver variable to a given target. We show that adopting an unnormalized definition of Granger causality one may put in evidence redundant multiplets of variables influencing the target by maximizing the total Granger causality to a given target, over all the possible partitions of the set of driving variables. Consequently we introduce a pairwise index of synergy which is zero when two in…

FOS: Computer and information sciencesgranger causality (GC)Multivariate statisticsComputer scienceRestComputer Science - Information TheoryBiomedical EngineeringsynergyFOS: Physical sciencescomputer.software_genre01 natural sciences03 medical and health sciences0302 clinical medicineGranger causality0103 physical sciencesConnectomeRedundancy (engineering)HumansBrain connectivityTime series010306 general physicsModels StatisticalHuman Connectome ProjectResting state fMRIredundancybusiness.industryInformation Theory (cs.IT)functional magnetic resonance imaging (fMRI)BrainPattern recognitionComplex networkMagnetic Resonance ImagingVariable (computer science)Physics - Data Analysis Statistics and ProbabilityQuantitative Biology - Neurons and CognitionFOS: Biological sciencesSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaPairwise comparisonNeurons and Cognition (q-bio.NC)Artificial intelligenceData miningNerve Netbusinesscomputer030217 neurology & neurosurgeryData Analysis Statistics and Probability (physics.data-an)
researchProduct

Bifurcation analysis of a TaO memristor model

2019

This paper presents a study of bifurcation in the time-averaged dynamics of TaO memristors driven by narrow pulses of alternating polarities. The analysis, based on a physics-inspired model, focuses on the stable fixed points and on how these are affected by the pulse parameters. Our main finding is the identification of a driving regime when two stable fixed points exist simultaneously. To the best of our knowledge, such bistability is identified in a single memristor for the first time. This result can be readily tested experimentally, and is expected to be useful in future memristor circuit designs.

FOS: Computer and information sciencesstable fixed pointAcoustics and UltrasonicsBistabilityFOS: Physical sciencesComputer Science - Emerging Technologies02 engineering and technologyMemristorFixed pointTopology01 natural scienceslaw.inventionComputer Science::Emerging TechnologieslawMesoscale and Nanoscale Physics (cond-mat.mes-hall)0103 physical sciencesresistance switching memoriesmemristorBifurcation010302 applied physicsPhysicsCondensed Matter - Mesoscale and Nanoscale PhysicsNonlinear Sciences - Chaotic Dynamics021001 nanoscience & nanotechnologyCondensed Matter PhysicsNonlinear Sciences - Adaptation and Self-Organizing SystemsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsPulse (physics)Emerging Technologies (cs.ET)Bifurcation analysisbifurcationChaotic Dynamics (nlin.CD)0210 nano-technologyAdaptation and Self-Organizing Systems (nlin.AO)Journal of Physics D: Applied Physics
researchProduct

Imaging of metabolic and overload disorders in tissues and organs

2023

Metabolic and overload disorders are a heterogeneous group of relatively uncommon but important diseases. While imaging plays a key role in the early detection and accurate diagnosis in specific organs with a pivotal role in several metabolic pathways, most of these diseases affect different tissues as part of a systemic syndromes. Moreover, since the symptoms are often vague and phenotypes similar, imaging alterations can present as incidental findings, which must be recognized and interpreted in the light of further biochemical and histological investigations. Among imaging modalities, MRI allows, thanks to its multiparametric properties, to obtain numerous information on tissue compositi…

Fabry diseaseHemochromatosiRadiology Nuclear Medicine and imagingOverload disorderMetabolic disorderCTMRI
researchProduct

Robustness Analysis of DCE-MRI-Derived Radiomic Features in Breast Masses: Assessing Quantization Levels and Segmentation Agreement

2022

Featured Application The use of highly robust radiomic features is fundamental to reduce intrinsic dependencies and to provide reliable predictive models. This work presents a study on breast tumor DCE-MRI considering the radiomic feature robustness against the quantization settings and segmentation methods. Machine learning models based on radiomic features allow us to obtain biomarkers that are capable of modeling the disease and that are able to support the clinical routine. Recent studies have shown that it is fundamental that the computed features are robust and reproducible. Although several initiatives to standardize the definition and extraction process of biomarkers are ongoing, th…

Fluid Flow and Transfer Processesradiomic featuresrobustness analysis; radiomic features; quantization levels; segmentation method agreement; DCE-MRI; breast tumorsbreast tumorDCE-MRIProcess Chemistry and TechnologyGeneral Engineeringbreast tumors; DCE-MRI; quantization levels; radiomic features; robustness analysis; segmentation method agreementComputer Science Applicationsquantization levelsrobustness analysisGeneral Materials Sciencesegmentation method agreementbreast tumorsInstrumentation
researchProduct

Characterization of focal liver lesions undetermined at grayscale US: contrast-enhanced US versus 64-row MDCT and MRI with liver specific contrast ag…

2011

Focal liver lesionMDCTSettore MED/36 - Diagnostica Per Immagini E RadioterapiaMRI
researchProduct

Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI

2017

One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiationsensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gel). In this work Fricke gel dosimeters produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GT…

Fricke Gel Dosimetry LINAC Dose Dosimetria Radioterapia Diffusione MRISettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

PVA-GTA Fricke gel: studio della risposta NMR in funzione della concentrazione degli additivi e studi preliminari con scanner MRI 7 T

2016

Sono stati analizzati tramite rilassometria NMR ed acquisizioni MRI dosimetri gel di tipo Fricke realizzati utilizzando un'innovativa matrice gel sintetica e tessuto equivalente: Polyvinyl alcohol (PVA) attivando chimicamente il processo di gelificazione tramite l'aggiunta di Glutaraldehyde (GTA). Questi gel sono stati irradiati con fasci di fotoni (LINAC) nel range 0--20 Gy. Per valutare la sensibilità a fotoni è stata studiata la dipendenza dei tempi di rilassamento nucleari dalla dose e dalla concentrazione di ferro nei gel. Inoltre è stata monitorata la stabilità del segnale dopo l'irraggiamento. Acquisizioni preliminari MRI con uno scanner MRI da 7 T sono state affiancate alle misure N…

Fricke gel MRI NMR 7T Dosimetria 3DSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Testing and calibration of ESR response of Fricke gel dosimeters in mixed neutron-gamma fields

2013

Fricke gel Neutron NMR MRI DosimetrySettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Characterization of Fricke gel dosimeters exposed to gamma rays and neutrons

2013

Fricke gel neutrons gamma rays NMR MRISettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Assessing High-Order Interdependencies Through Static O-Information Measures Computed on Resting State fMRI Intrinsic Component Networks

2022

Resting state brain networks have reached a strong popularity in recent scientific endeavors due to their feasibility to characterize the metabolic mechanisms at the basis of neural control when the brain is not engaged in any task. The evaluation of these states, consisting in complex physiological processes employing a large amount of energy, is carried out from diagnostic images acquired through resting-state functionalmagnetic resonance (RS-fMRI) on different populations of subjects. In the present study, RS-fMRI signals from the WU-MinnHCP 1200 Subjects Data Release of the Human Connectome Project were studied with the aim of investigating the high order organizational structure of the…

Functional magnetic resonance imaging (fMRI)O-Information (OI)Settore ING-INF/06 - Bioingegneria Elettronica E InformaticaIndependent Component Analysis (ICA)Complex networkHigh-order interactionResting State Networks (RSN)
researchProduct