Search results for "Magnetic flux"
showing 10 items of 80 documents
The Magnetic Properties of Electrical Pulses Delivered by Deep-Brain Stimulation Systems
2020
The aim of this article is to analyze the magnetic field properties for both the monopolar and bipolar electrode configurations of deep-brain stimulation electrodes using 3-D magnetic field measurements and to investigate if the magnetic measurements enable a localization of the electrode as a proof of concept. Therefore, a simplified head phantom with an integrated deep-brain stimulation electrode was created to measure the magnetic flux densities in all the three dimensions with a fluxgate magnetometer over a sensor trajectory of measuring points inside the magnetically shielded chamber. The magnitude of the magnetic flux density for monopolar stimulation and bipolar stimulation is in the…
Temperature Dependence of Irradiation-Induced Magnetic Flux Loss in Nd 2 Fe 14 B Permanent Magnets
1990
Nd2Fe14B permanent magnets were irradiated with 20 MeV protons at 300 K and at 15 K, and the flux loss was measured as a function of the irradiation dose. The results show that at 15 K the Nd2Fe14B magnets can withstand particle radiation at least 1000 times more than at room temperature.
Diamond magnetometer enhanced by ferrite flux concentrators
2020
Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (<1 kHz) is presently >10 pT s^{1/2}, precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~250-fold increase of the magnetic field amplitude wi…
Improvement of IPMSM performance through a mixed radial-tangential rotor structure
2010
In this paper an IPMSM (Interior Permanent Magnet Synchronous Motor) rotor configuration optimization is proposed in order to increase the performances in terms of torque, limiting at the same time the rotor leakage flux. The final mixed radial and tangential rotor configuration here proposed and described determines a reduction in PM material quantity of about 25% compared to a tangential IPMSM one with the same dimension and weight, together with an increase of the motoring torque of about 50%. Some simulation carried out by using a FEM software and a comparative analysis with two traditional IPMSMs rotor configurations show that a significant improvement can be achieved with limited chan…
Energy of dendritic avalanches in thin-film superconductors
2018
A method for calculating stored magnetic energy in a thin superconducting film based on quantitative magneto-optical imaging is developed. Energy and magnetic moment are determined with these calculations for full hysteresis loops in a thin film of the superconductor NbN. Huge losses in energy are observed when dendritic avalanches occur. Magnetic energy, magnetic moment, sheet current and magnetic flux distributions, all extracted from the same calibrated magneto-optical images, are analyzed and discussed. Dissipated energy and the loss in moment when dendritic avalanches occur are related to each other. Calculating these losses for specific spatially-resolved flux avalanches is a great ad…
Application of spin-exchange relaxation-free magnetometry to the Cosmic Axion Spin Precession Experiment
2018
The Cosmic Axion Spin Precession Experiment (CASPEr) seeks to measure oscillating torques on nuclear spins caused by axion or axion-like-particle (ALP) dark matter via nuclear magnetic resonance (NMR) techniques. A sample spin-polarized along a leading magnetic field experiences a resonance when the Larmor frequency matches the axion/ALP Compton frequency, generating precessing transverse nuclear magnetization. Here we demonstrate a Spin-Exchange Relaxation-Free (SERF) magnetometer with sensitivity $\approx 1~{\rm fT/\sqrt{Hz}}$ and an effective sensing volume of 0.1 $\rm{cm^3}$ that may be useful for NMR detection in CASPEr. A potential drawback of SERF-magnetometer-based NMR detection is …
Fractional Periodicity of Persistent Currents: A Signature of Broken Internal Symmetry
2003
We show from the symmetries of the many body Hamiltonian, cast into the form of the Heisenberg (spin) Hamiltonian, that the fractional periodicities of persistent currents are due to the breakdown of internal symmetry and the spin Hamiltonian holds the explanation to this transition. Numerical diagonalizations are performed to show this explicitely. Persistent currents therefore, provide an easy way to experimentally verify broken internal symmetry in electronic systems.
The Cryogenic Pumping Section of the KATRIN Experiment
2010
In order to determine the absolute scale of the neutrino mass with a sensitivity of 0.2 (90% Confidence Level), the Karlsruhe Tritium Neutrino experiment (KATRIN) operates a series of superconducting magnet systems, which guide the electrons adiabatically from the source of tritium beta-decay to the detector within a magnetic flux of 191 . The 7 m long Cryogenic Pumping Section (CPS) is designed as the final barrier of tritium circulation. It has to reduce the tritium partial pressure below Pa in order to limit the background count rate in the measurement. To achieve this, the tritium entering the CPS must be adsorbed onto a pre-condensed argon layer on the inner surface of the beam tube at…
Features of level broadening in a ring-stub system
2000
When a one dimensional (1D) ring-stub system is coupled to an electron reservoir, the states acquire a width (or broadening characterized by poles in the complex energy plane) due to finite life time effects. We show that this broadening is limited by anti-resonances due to the stub. The differences in level broadening in presence and absence of anti-resonance is exemplified by comparison to a 1D ring coupled to an infinite reservoir. We also show that the anti-resonances due to the stub has an anchoring effect on the poles when a magnetic flux through the ring is varied. This will have implication on change in distribution of the poles in disordered multichannel situation as magnetic flux …
Energy spectrum, persistent current and electron localization in quantum rings
2003
Energy spectra of quasi-one-dimensional quantum rings with a few electrons are studied using several different theoretical methods. Discrete Hubbard models and continuum models are shown to give similar results governed by the special features of the one-dimensionality. The energy spectrum of the many-body system can be described with a rotation-vibration spectrum of a 'Wigner molecule' of 'localized' electrons, combined with the spin-state determined from an effective antiferromagnetic Heisenberg Hamiltonian. The persistent current as a function of magnetic flux through the ring shows periodic oscillations arising from the 'rigid rotation' of the electron ring. For polarized electrons the …