Search results for "Manga"

showing 10 items of 743 documents

Contribution to the adsorption voltammetric determination of manganese

1994

The adsorption voltammetric determination of Mn(II) with Bromopyrogallol Red (BPR) and Mordant Red 19 (MDR) has been investigated using a hanging drop mercury electrode. In NH3/NH4Cl solution, ligands and Mn(II) complexes give well separated voltammetric peaks after enrichment onto the electrode. The conditions for determining manganese by adsorption voltammetry with these reagents have been investigated in detail, as has the influence of foreign ions on the determination. The detection limits are 4·10−10 mol/L Mn for BPR and 8·10−10 mol/L Mn for MDR, respectively.

Detection limitBromopyrogallol redChromatographychemistry.chemical_elementMordantManganeseDropping mercury electrodeBiochemistryAnalytical Chemistrychemistry.chemical_compoundAdsorptionchemistryReagentVoltammetryNuclear chemistryFresenius' Journal of Analytical Chemistry
researchProduct

Flow injection flame atomic absorption analysis of Fe and Mn in cement samples

1993

A new procedure has been developed for the determination of Fe and Mn in cements. It consists in dispersing 50 mg of the solid sample in 25 ml of 0.15 mol/l HNO3 and 0.12 mol/l HCl solution. Acid slurries are heated at 50°C for 10 min and then different volumes of the slurry are injected into a water carrier stream. This previous acid treatment leaches the elements to be determined and permits the use of acid solutions as standards. For the Mn determination, the use of a single line flow injection manifold provides a limit of detection of 0.03 mgl−1 and a dynamic range up to 6 mgl−1. For the determination of Fe, the on-line dispersion of samples, using a well stirred mixing chamber, increas…

Detection limitCementChemistryAnalytical chemistrychemistry.chemical_elementManganeseBiochemistrylaw.inventionCertified reference materialslawSlurrySample preparationDispersion (chemistry)Atomic absorption spectroscopyFresenius' Journal of Analytical Chemistry
researchProduct

New flow-multicommutation method for the photo-chemiluminometric determination of the carbamate pesticide asulam

2004

This paper deals with a straightforward automated method for the determination of asulam in water based on the use of a flow manifold including three computer-controlled solenoid valves. The method involves irradiating on an aqueous solution of asulam in glycine buffer at pH 8.3 with UV light during 90 s, then follows the oxidation with potassium permanganate in a sulphuric medium and chemiluminescence-based detection of the resulting photoproducts. The limit of detection thus achieved is 40 mug l(-1). The detector response is linear up to a 5 mg l(-1) asulam concentration and the throughput is 30 samples h(-1). In parallel tests, oxidation with alkaline ferricyanide was also assessed and t…

Detection limitChemiluminescenceChromatographyAqueous solutionSolenoid valvesBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganateAsulamchemistrylawMulticommutationReagentPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryAsulamFerricyanidePhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

A tandem-flow assembly for the chemiluminometric determination of hydroquinone

2003

A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…

Detection limitChemiluminescenceChromatographyHydroquinoneHydroquinonePermanganateAnalytical chemistrySulfuric acidAnalytical Chemistrylaw.inventionchemistry.chemical_compoundBenzalkonium chloridePotassium permanganatechemistryEnvironmental sampleslawTandem-flowQUIMICA ANALITICAmedicinePharmaceuticalsLight emissionChemiluminescencemedicine.drugTalanta
researchProduct

Flow‐Injection Chemiluminescent Determination of Thiamine in Pharmaceutical Samples by On‐line Photodegradation

2004

Abstract A simple, sensitive, and precise method for the determination of thiamine hydrochloride in a flow‐injection system is described. The method is based on the UV irradiation of thiamine in acid medium. Then, the photo‐fragments are oxidized by permanganate in acid medium, and the resultant chemiluminescent intensity is measured. The optimum conditions for the photoreaction and for the chemiluminescence emission were investigated. The method allows the determination of thiamine, over the range 0.05(LOD)–84 mg · l−1, with a throughput of 30 h−1, and a RSD (n, 20) at 20 and 0.5 mg · l−1 of the thiamine level of 2.5 and 1.3%, respectively. The method was applied to pharmaceutical preparat…

Detection limitChromatographyBiochemistry (medical)Clinical BiochemistryThiamine HydrochloridePermanganatefood and beveragesPhotochemistryBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundchemistrylawElectrochemistryPhotochemical degradationThiamineIrradiationPhotodegradationhuman activitiesSpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Photochemical-chemiliminometric determination of aldicarb in a fully automated multicommutation based flow-assembly

2004

[EN] A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) and mineral waters is proposed. The automation of the flow-assembly is based on the multicommutation approach, which uses a set of solenoid valves acting as independent switchers. The operating cycle for obtaining a typical analytical transient signal can be easily programmed by means of a home-made software running in the Windows environment. The manifold is provided with a photoreactor consisting of a 150 cm long x 0.8 mm i.d. piece of PTFE tubing coiled around a 20 W low-pressure mercury lamp. The determination of aldicarb is performed on the basis of the iron(III) catalytic minera…

Detection limitChromatographyChemiluminescenceAldicarbAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundPotassium permanganatechemistryFully automatedlawMulticommutationTandem-flowPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryPhotodegradationSpectroscopyTransient signalAldicarbChemiluminescence
researchProduct

Analytical strategy photodegradation/chemiluminescence/continuous-flow multicommutation methodology for the determination of the herbicide Propanil

2006

The present paper is dealing with an analytical strategy based on coupling photodegradation, chemiluminescence and multicommutation continuous-flow methodology for the determination of the pesticide Propanil, a common herbicide. The pesticide solution is inserted as small segments sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. Both flow-rates (sample and medium) are adjusted to required time for photodegradation, 2.0 min; and then, the resulting solution is also sequentially inserted as segments alternated with segments of the oxidizing solutions system, 1.00 x 10(-4) mol 1(-1) potassium permanganate in 2.00 mol 1(-1) sulphu…

Detection limitChromatographyChemiluminescenceCorrelation coefficientChemistryAlachlorAnalytical chemistryRepeatabilityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatePhotoreactionlawMulticommutationPropanilQUIMICA ANALITICAPesticidesPhotodegradationChemiluminescence
researchProduct

A Fully Automated Assembly Using Solenoid Valves for the Photodegradation and Chemiluminometric Determination of the Herbicide Chlorsulfuron

2005

Abstract This paper presents a new photochemiluminescent system for the determination of chlorsulfuron in water samples. The light from a low‐pressure mercury lamp is used as a clean, reproducible, and inexpensive “reagent” for the derivation of the pesticide, performed in glycine buffer at pH 9.5. Then, the photo‐products from irradiation are oxidized by permanganate in sulfuric acid solution. The oxidation reaction was favored by using high temperatures. A comparative study and discussion about the use of polyphosphoric acid instead of sulfuric acid in the oxidation reaction is also presented. The use of solenoid valves allows for the easy, complete automation of the process with low samp…

Detection limitChromatographyChemistryCalibration curveBiochemistry (medical)Clinical BiochemistryPermanganateAnalytical chemistrySulfuric acidBiochemistryRedoxAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundlawReagentElectrochemistryPhotodegradationSpectroscopyAnalytical Letters
researchProduct

FI-on line photochemical reaction for direct chemiluminescence determination of photodegradated chloramphenicol.

2002

Abstract A new, simple, clean and selective flow injection strategy based on the tandem photochemical reaction-chemiluminescence detection was applied to the determination of chloramphenicol. The determination is based on the on-line photodegradation of the drug in a glycine buffer at pH 8.8 by using a photoreactor consisting of 697 cm×0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegradated chloramphenicol is detected by direct chemiluminescence of resulting photo-fragments and their subsequent reaction with potassium permanganate in sulfuric acid medium as oxidant. The method allows the chemiluminescence determination of compounds which do not exhibit n…

Detection limitChromatographyChemistryCalibration curvePhotochemistryDosage formAnalytical Chemistrylaw.inventionPotassium permanganatechemistry.chemical_compoundlawPhotodegradationQuantitative analysis (chemistry)Antibacterial agentChemiluminescenceTalanta
researchProduct

Flow injection-chemiluminescence determination of octyl dimethyl PABA in sunscreen formulations

2002

Abstract A sensitive flow injection (FI) procedure was developed for the determination of the UV-filter octyl dimethyl PABA in sunscreen formulations based on its chemiluminescence (CL) induced by potassium permanganate in sulfuric acid. Both second-order and log–log calibration graphs can be used to perform the analysis. Ninety injections per hour can be carried out, which means a sample throughput of 18 h −1 if five injections per solution are performed. The limit of detection (3 σ ) was 25 ng ml −1 . The interference effects of the excipient and other UV filters are studied. Sunscreen formulations containing octyl dimethyl PABA were analysed by both the proposed FI-CL method and a liquid…

Detection limitChromatographyChemistryExcipientSulfuric acidBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatelawmedicineOCTYL DIMETHYL PABAEnvironmental ChemistrySpectroscopymedicine.drugChemiluminescenceAnalytica Chimica Acta
researchProduct