Search results for "Mass spectrometer"

showing 10 items of 75 documents

Nuts and dried fruits: Natural occurrence of emerging Fusarium mycotoxins

2013

Abstract The occurrence of enniatins (ENs) and beauvericin (BEA) in nuts, dried fruits and dates available in Valencia (Spain) was surveyed in this study. To do this, seventy-four samples of nuts, dried fruits and dates were analyzed for the determination of mycotoxin contamination. Mycotoxins were identified and quantified using an ultrasonic-C18 extraction and LC–MS/MS with a triple quadrupole (QqQ) mass analyzer. The frequencies of contamination of nuts, shell, dried fruits and dates were 50%, 80%, 35.7% and 83.3%, respectively. Enniatin A (ENA) was the most predominant EN found in nuts (45.2%) while ENB was the most common EN found in dates (58.3%). The analytical results of the shell s…

FusariumbiologyDried fruitContaminationbiology.organism_classificationBeauvericinTriple quadrupole mass spectrometerchemistry.chemical_compoundchemistryMass analyzerFood scienceMycotoxinEnniatin AFood ScienceBiotechnologyFood Control
researchProduct

(Supplement Table S2) Results of 230Th/U-dating

2016

We compared the suitability of two skeletal materials of the Atlantic brain coral Diploria strigosa for 230Th/U-dating: the commonly used bulk material comprising all skeletal elements and the denser theca wall material. Eight fossil corals of presumably Last Interglacial age from Bonaire, southern Caribbean Sea, were investigated, and several sub-samples were dated from each coral. For four corals, both the ages and the activity ratios of the bulk material and theca wall agree within uncertainty. Three corals show significantly older ages for their bulk material than for their theca wall material as well as substantially elevated 232Th content and (230Th/238U) ratios. The bulk material sam…

Hand drillUranium 238Thorium 230 Uranium 238 activity ratioThorium-230/Uranium-238 activity ratioUranium-238Thorium-230/Uranium-238 activity ratio standard deviationAGECenter for Marine Environmental Sciences MARUMMulti collector inductively coupled plasma mass spectrometer MC ICP MSCenter for Marine Environmental Sciences (MARUM)Thorium 232Thorium 232 Uranium 238 activity ratioThorium-232/Uranium-238 activity ratio standard deviationEvent labelCommentUranium 234 Uranium 238 activity ratioUranium-234/Uranium-238 activity ratioDrilling/drill rigAge 230Th/U Thorium-UraniumAge standard deviationDrilling drill rigThorium-232/Uranium-238 activity ratioUranium-234/Uranium-238 activity ratio standard deviationThorium-232230Th U Thorium UraniumEarth System ResearchGroupMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)standard deviation
researchProduct

Quantitative determination of trichothecenes in breadsticks by gas chromatography-triple quadrupole tandem mass spectrometry.

2014

Breadsticks are pencil-sized sticks of dry bread widely consumed as a pre-meal appetiser. They are basically wheat-based snacks, which makes them a good matrix to evaluate mycotoxin contamination, since wheat is very susceptible to fungal attack. In this sense, the fast, selective and sensitive gas chromatography-triple quadrupole tandem mass spectrometry (GCQqQ- MS/MS) method proposed here allows simultaneous determination of deoxynivalenol (DON), 3-acetyldeoxynivalenol, fusarenon-X, diacetoxyscirpenol, nivalenol, neosolaniol, HT-2 and T-2 toxin in breadsticks after QuEChERS extraction and clean-up. The performance of the method was assessed with respect to European Commission Regulations …

Health Toxicology and MutagenesisAnalytical chemistryFood ContaminationToxicologyTandem mass spectrometryQuechersDiacetoxyscirpenolGas Chromatography-Mass SpectrometryMatrix (chemical analysis)chemistry.chemical_compoundLimit of DetectionTandem Mass SpectrometryToxicologiaMycotoxinDetection limitChromatographyChemistryPublic Health Environmental and Occupational Healthfood and beveragesAliments ToxicologiaGeneral ChemistryGeneral MedicineBreadEnvironmental ExposureTriple quadrupole mass spectrometerGas chromatographyTrichothecenesFood ScienceFood additivescontaminants. Part A, Chemistry, analysis, control, exposurerisk assessment
researchProduct

Degradation study of enniatins by liquid chromatography–triple quadrupole linear ion trap mass spectrometry

2012

Abstract Enniatins A, A1, B and B1 (ENs) are mycotoxins produced by Fusarium spp. and are normal contaminants of cereals and derivate products. In this study, the stability of ENs was evaluated during food processing by simulation of pasta cooking. Thermal treatments at different incubation times (5, 10 and 15 min) and different pH (4, 7 and 10) were applied in an aqueous system and pasta resembling system (PRS). The concentrations of the targeted mycotoxins were determined using liquid chromatography coupled to tandem mass spectrometry. High percentages of ENs reduction (81–100%) were evidenced in the PRS after the treatments at 5, 10 and 15 min of incubation. In contrast to the PRS, an im…

Hot TemperatureAqueous solutionChromatographyMolecular StructureChemistryfood and beveragesGeneral MedicineMycotoxinsContaminationMass spectrometryTandem mass spectrometryMass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerchemistry.chemical_compoundDepsipeptidesQuadrupole ion trapMycotoxinIncubationChromatography High Pressure LiquidTriticumFood ScienceFood Chemistry
researchProduct

Kompakti automatisoitu laser-ionisointijärjestelmä

2011

In an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master’s thesis I discuss mostly about automation which was used in our off-line system. The system was built at the Ion Guide Separator On-Line facility (IGISOL) in Jyväskylä University. The automation set up was made with the Phoenix Contacts inline terminals, which were programmed by using the Labview program. The system consists of thermistor, skimmer handling, mirror handling, gasline parts per billion (ppb) mixing and quadrupole mass spectrometer measurement. There were major p…

Labviewvacuumquadrupole mass spectrometerlasertekniikkaoff-linelaser-ionisaatioautomaatiogas impurityexperimental nuclear physicskokeellinen ydinfysiikkalaser-ionizationydinfysiikkakvadrupolimassaspektrometrityhjiöautomationepäpuhtaudet
researchProduct

Calcium Carbonate and Phosphate Reference Materials for Monitoring Bulk and Microanalytical Determination of Sr Isotopes

2017

In situ laser ablation analyses rely on the microanalytical homogeneity of reference materials (RMs) and a similar matrix and mass fraction between unknown samples and RMs to obtain reliable results. Suitable carbonate and phosphate RMs for determination of Sr isotope ratios in such materials are limited. Thus, we determined Sr-87/Sr-86 ratios of several carbonate (JCt-1, JCp-1, MACS-1, MACS-3) and phosphate (MAPS-4, MAPS-5, NIST SRM 1400, NIST SRM 1486) international RMs using dissolved samples and two different multi-collector inductively coupled plasma-mass spectrometers (MC-ICP-MS). Our Sr isotope data are in agreement with published data and have an improved measurement precision for s…

MACS-1phosphatesMACS-3LA-MC-ICP-MS010502 geochemistry & geophysics01 natural sciencesNIST SRM 1400carbonate and phosphate reference materialsLA-MC-ICP-MS MC-ICP-MS carbonate and phosphate reference materials JCt-1 JCp-1 MACS-1 MACS-3 MAPS-4 MAPS-5 NIST SRM 1400 NIST SRM 1486NIST SRM 1486chemistry.chemical_compoundGeochemistry and Petrologycalcium carbonateMC-ICP-MSreference material0105 earth and related environmental sciencesLaser ablationIsotopeChemistryMc icp ms010401 analytical chemistryGeologyPhosphateIsotopes of strontiumstrontium isotope0104 chemical sciencesMAPS-4Calcium carbonateJCp-1JCt-1laser ablationMAPS-5Nuclear chemistrymulti-collector inductively coupled plasma-mass spectrometer
researchProduct

Targeting metabolomics analysis of the sunscreen agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate in human urine by automated on-line solid-phase ext…

2011

The in vivo metabolism of the xenobiotic agent 2-ethylhexyl 4-(N,N-dimethylamino)benzoate (EDP), a UV filter commonly used in sunscreen cosmetic products, was studied by targeting metabolomics analysis in human urine. The metabolomic study involved the use of urine from male and female volunteers before and after application of an EDP-containing sunscreen cosmetic. The metabolism of EDP in urine was studied by using the triple quadrupole detector in a combination of Precursor Ion Scanning and Neutral Loss Scanning modes, with and without enzymatic hydrolysis. Detected metabolites were subsequently confirmed as glucuronide conjugates of 4-(N,N-dimethylamino)benzoic acid and 4-(N-methylamino)…

MaleSkin AbsorptionTandem mass spectrometryMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySonicationDrug StabilityTandem Mass SpectrometryLiquid chromatography–mass spectrometrypara-AminobenzoatesHumansMetabolomicsSolid phase extractionGlucuronidaseChromatographyChemistryHydrolysisSolid Phase ExtractionOrganic ChemistryGeneral MedicineTriple quadrupole mass spectrometerStandard additionMetabolomeFemaleSulfatasesTime-of-flight mass spectrometry4-Aminobenzoic AcidSunscreening AgentsChromatography LiquidJournal of Chromatography A
researchProduct

High-accuracy mass measurements on neutron deficient neon isotopes

2005

International audience; The atomic masses of the short-lived nuclides 17Ne and 19Ne have been measured with the triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN. The obtained mass excess for both nuclides deviates significantly from the literature value, in the case of 17Ne about 40 keV. The mass value of 17Ne can be applied for a test of the isobaric multiplet mass equation with respect to an isospin T = 3/2 quartet. In addition, both masses can contribute to the data analysis of collinear laser-spectroscopy experiments where mean-square nuclear-charge radii are determined.

Mass excessNuclear Theorychemistry.chemical_element[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciences7. Clean energyISOLTRAPNuclear physicsNeonnuclei with mass number 6 to 190103 physical sciencesNuclideneon010306 general physicsNuclear ExperimentPhysicsmass spectrometers010308 nuclear & particles physicsneutronsAtomic massMass formulaMass21.10.Dr 27.20.+n 29.30.-hIsotopes of neonchemistrynuclear massAtomic physics
researchProduct

Co-occurrence and risk assessment of mycotoxins in food and diet from Mediterranean area.

2012

The contents of 14 mycotoxins were studied in samples of different cereals and cereal products from four countries of the Mediterranean region. Two hundred and sixty-five samples from Spain, Italy, Morocco and Tunisia were analysed. Samples were extracted with matrix solid-phase dispersion (MSPD) and determined by liquid chromatography-tandem mass spectrometry with a triple quadrupole mass analyser. The percentage of total samples contaminated was 53%. The frequency of contaminated samples from Spain, Italy, Tunisia and Morocco was 33%, 52%, 96% and 50%, respectively. Nivalenol and beauvericin were the most predominant mycotoxins. This is the first international report to study the presence…

Mediterranean climateMediterranean Regiondigestive oral and skin physiologyfood and beveragesFood ContaminationGeneral MedicineBiologyMycotoxinsSorghumbiology.organism_classificationRisk AssessmentBeauvericinAnalytical ChemistryTriple quadrupole mass spectrometerchemistry.chemical_compoundchemistryLc ms msMediterranean areaHumansFood scienceMycotoxinRisk assessmentEdible GrainFood AnalysisFood ScienceFood chemistry
researchProduct

Ramsey technique applied in a Penning trap mass spectrometer

1991

Abstract The Ramsey method has been applied in an experiment aiming for accurate mass determination of unstable isotopes. The ion motion in a Penning trap has been excited with time-separated oscillatory fields and Ramsey fringes were observed in the case of dipole and quadrupole excitation. The experimental resonances are in good agreement with theory. Further applications of the technique are discussed.

Nuclear and High Energy PhysicsChemistryMass spectrometryPenning trapDipoleQuadrupolePhysics::Atomic PhysicsIon trapDetectors and Experimental TechniquesAtomic physicsQuadrupole ion trapInstrumentationQuadrupole mass analyzerHybrid mass spectrometerNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct