Search results for "Mass"

showing 10 items of 9693 documents

Quartz resonators for penning traps toward mass spectrometry on the heaviest ions

2020

We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…

010302 applied physicsMaterials scienceSidebandCyclotronMass spectrometry01 natural sciences7. Clean energyAtomic mass010305 fluids & plasmaslaw.inventionIonCrystalResonatorPhysics::Plasma Physicslaw0103 physical sciencesAtomic physicsddc:620InstrumentationQuartz
researchProduct

Fluence effect on ion-implanted As diffusion in relaxed SiGe

2005

A systematic study on the fluence (5 × 108 − 4 × 1014 cm−2) dependence of ion-implanted As diffusion in relaxed Si1 − xGex alloys (with x = 0.2, 0.35 and 0.5) and silicon has been performed by the modified radiotracer and secondary ion mass spectrometry techniques. With fluences above 4 × 1011 cm−2 a clear fluence-dependent enhancement in arsenic diffusion was noted for Si1 − xGex. In case of arsenic-implanted silicon such fluence dependency was not observed. This can be assigned to enhanced implantation-induced damage formation and more deficient radiation damage recovery of SiGe.

010302 applied physicsMaterials scienceSiliconAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_element02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesFluenceIonSecondary ion mass spectrometrychemistry0103 physical sciencesRadiation damageDiffusion (business)0210 nano-technologyArsenicEurophysics Letters
researchProduct

HCl gas gettering of low-cost silicon

2013

HCl gas gettering is a cheap and simple technique to reduce transition metal concentrations in silicon. It is attractive especially for low-cost silicon materials like upgraded metallurgical grade (UMG) silicon, which usually contain 3d transition metals in high concentrations. Etching of silicon by HCl gas occurs during HCl gas gettering above a certain onset temperature. The etching rate as well as the gettering efficiency was experimentally determined as a function of the gettering temperature, using UMG silicon wafers. The activation energy of the etching reaction by HCl gas was calculated from the obtained data. The gettering efficiency was determined by analyzing Ni as a representativ…

010302 applied physicsMaterials scienceSiliconEtching rateInorganic chemistrychemistry.chemical_element02 engineering and technologySurfaces and InterfacesActivation energy021001 nanoscience & nanotechnologyCondensed Matter Physics7. Clean energy01 natural sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialschemistryTransition metalGetterEtching (microfabrication)0103 physical sciencesMaterials ChemistryWaferElectrical and Electronic Engineering0210 nano-technologyInductively coupled plasma mass spectrometryphysica status solidi (a)
researchProduct

Correlations between density distributions, optical spectra, and ion species in a hydrogen plasma (invited)

2016

An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H + , H + 2 , and H + 3 ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical facto…

010302 applied physicsMaterials scienceWien filterta114Hydrogenchemistry.chemical_elemention speciesPlasma01 natural sciences010305 fluids & plasmasIonchemistryPhysics::Plasma Physics0103 physical scienceshydrogen plasmaMass spectrumPlasma diagnosticsEmission spectrumAtomic physicsdensity distributionsoptical spectraInstrumentationVisible spectrumReview of Scientific Instruments
researchProduct

Annealing behaviour of aluminium-implanted InP

2000

The annealing behaviour of aluminium has been studied in single-crystal InP implanted with 40 and 120 keV 27Al+ ions. The implantation doses were 1 x 1015 and 1 x 1016 cm-2. The aluminium concentration profiles were determined by two techniques, Secondary ion mass spectrometry (SIMS) and the nuclear resonance broadening technique (NRB) which was used for checking purposes. The usability of the SIMS technique for profiling Al rich layers was studied. Significant inconsistencies were observed in the SIMS profiles with the high dose implanted samples. The 120 keV, 1 x 1016 cm-2 implanted samples were subject to annealing in argon atmosphere in the temperature range 380–600°C. Redistribution an…

010302 applied physicsNuclear and High Energy PhysicsMaterials scienceAnnealing (metallurgy)Analytical chemistrychemistry.chemical_element02 engineering and technologyActivation energyAtmospheric temperature range021001 nanoscience & nanotechnology01 natural sciencesSpectral lineIonSecondary ion mass spectrometryIon implantationchemistryAluminium0103 physical sciences0210 nano-technologyInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Mass calibration of the energy axis in ToF- E elastic recoil detection analysis

2016

We report on procedures that we have developed to mass-calibrate the energy axis of ToF-E histograms in elastic recoil detection analysis. The obtained calibration parameters allow one to transform the ToF-E histogram into a calibrated ToF-M histogram.

010302 applied physicsPhysicsNuclear and High Energy Physicsta114Physics::Instrumentation and DetectorsPhysics::Medical PhysicsAstrophysics::Instrumentation and Methods for AstrophysicsERD02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesNuclear physicsElastic recoil detectionComputer Science::Computer Vision and Pattern RecognitionHistogramelastic recoil detection analysis0103 physical sciencesCalibrationmass calibrationToF-ENuclear Experiment0210 nano-technologyInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma

2017

A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…

010302 applied physicsPhysicsRange (particle radiation)plasma sourcesta114plasma diagnosticsPlasmaCondensed Matter PhysicsMass spectrometry01 natural sciences7. Clean energyIon source010305 fluids & plasmasIonplasma dynamicsPhysics::Plasma Physics0103 physical sciencesThermal emittancePlasma diagnosticsionAtomic physicsMicrowaveplasma sheathsPhysics of Plasmas
researchProduct

Charge breeding at GANIL: Improvements, results, and comparison with the other facilities

2019

International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…

010302 applied physicsPhysicsTest benchRange (particle radiation)mechanical instrumentstutkimuslaitteetCyclotronThermal ionization01 natural sciences7. Clean energyIon source010305 fluids & plasmaslaw.inventionNuclear physicsion sourcesUpgradeBreeder (animal)Beamlinenuclear physicslawion beam mass spectrometer0103 physical sciences[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]ydinfysiikkaInstrumentation
researchProduct

Magnetic field control of gas-liquid mass transfer in ferrofluids

2020

Abstract Gas-liquid mass transfer plays a key role in a broad range of industrial processes. The magnetic field control over the morphology of the gas-liquid interface and solute transport is an attractive feature if it can be realized efficiently. However, the magnetic properties of typical liquids and gases are rather weak. The experimental investigation is carried out to evaluate the effect of the magnetic field, which is mediated by magnetic nanoparticles, on the gas-liquid mass exchange during the sparging run through a hydrocarbon ferrofluid. The results indicate that the gradient field is especially effective at controlling the gas-liquid contact volume: the foaming of the liquid dur…

010302 applied physicsRange (particle radiation)FerrofluidMaterials science02 engineering and technology021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciencesElectronic Optical and Magnetic MaterialsMagnetic fieldPhysics::Fluid DynamicsCondensed Matter::Soft Condensed MatterVolume (thermodynamics)Chemical physicsMass transfer0103 physical sciencesMagnetic nanoparticlesVector field0210 nano-technologySpargingJournal of Magnetism and Magnetic Materials
researchProduct

Positron trapping defects in free-volume investigation of Ge–Ga–S–CsCl glasses

2016

Abstract Evolution of free-volume positron trapping defects caused by crystallization process in (80GeS 2 –20Ga 2 S 3 ) 100−х (СsCl) x , 0 ≤ x ≤ 15 chalcogenide-chalcohalide glasses was studied by positron annihilation lifetime technique. It is established that CsCl additives in Ge–Ga–S glassy matrix transform defect-related component spectra, indicating that the agglomeration of free-volume voids occurs in initial and crystallized (80GeS 2 –20Ga 2 S 3 ) 100−х (СsCl) x , 0 ≤ x ≤ 10 glasses. Void fragmentation in (80GeS 2 –20Ga 2 S 3 ) 85 (СsCl) 15 glass can be associated with loosing of their inner structure. Full crystallization in each of these glasses corresponds to the formation of defe…

010302 applied physicsVoid (astronomy)RadiationMaterials scienceAnalytical chemistryChalcogenide glassMineralogy02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesPositron trappingSpectral linelaw.inventionAbsorption edgeFragmentation (mass spectrometry)law0103 physical sciencesCrystallization0210 nano-technologyInstrumentationPositron annihilationRadiation Measurements
researchProduct