Search results for "Measurement uncertainty"
showing 10 items of 35 documents
Virtual Instruments: Uncertainty Evaluation in the Presence of Electromagnetic Interferences
2007
The electromagnetic interferences can influence the performances of a virtual instrument; consequently, in a generic measurement performed by using these instruments, the related uncertainty values can increase. In the paper, we report the results of various experimental tests performed with the aim to check if and how the radiated and/or conducted disturbances affect the instruments' characteristics and, in particular, the single uncertainty sources. Starting from these results and applying an already proposed method for the uncertainty estimation in the measurements performed by means of virtual instruments, it is possible to take into account and to evaluate the contribute of the electro…
A Monte Carlo Method for the Auto-Evaluation of the Uncertainties in the Analog-to-Digital Conversion-Based Measurements
2004
This paper concerns with the measurement uncertainty estimation in the analog‐to‐digital conversion‐based instruments. By using an ad hoc developed software tool, the Monte Carlo method is applied in order to assess the uncertainties associated with the measurement results, overcoming the possible inapplicability of the pure theoretical approach prescribed in the ISO – “Guide to the Expression of Uncertainty in Measurement”. By implementing the software tool in the measurement instruments, the proposed approach can be utilized in order to make the instrument itself able to auto‐estimate the measurement uncertainties.
Uncertainty evaluation of a Backward/Forward Load Flow algorithm for a MV smart grid
2015
This paper presents the uncertainty evaluation of an innovative measurement algorithm for load flow analysis in MV distribution networks. The measurement procedure is based on Low Voltage (LV) load power measurements applied on a Backward/Forward (B/F) algorithm for the Load Flow (LF) resolution. Furthermore, in the procedure a three phase voltage measurement at the MV generating substation bus-bars is also considered. The accuracy analysis of the LF algorithm is performed in the case of a real load condition in the distribution grid of Ustica island, Italy. The analysis takes into account the uncertainty of the measurement instruments at the LV side of each secondary substation power trans…
Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010
2020
The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …
Robust output feedback control of non-collocated low-damped oscillating load
2021
For systems with order of dynamics higher than two and oscillating loads with low damping, a non-collocation of the sensing and control can deteriorate robustness of the feedback and, in worst case, even bring it to instability. Furthermore, for a contactless sensing of the oscillating mechanical load, like in the system under investigation, the control structure is often restricted to the single proportional feedback only. This paper proposes a novel robust feedback control scheme for a low-damped fourth-order system using solely the measured load displacement. For reference tracking, the loop shaping design relies on a band reject filter, while the plant uncertainties are used as robustne…
Measurement uncertainty impact on simplified load flow analysis in MV smart grids
2018
This work is focused on the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. In more detail, the paper presents the uncertainty evaluation of a simplified load flow algorithm, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). To reduce the costs of the monitoring system, the load flow algorithm makes use of LV load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on the algorithm input quantities (load powers and slack b…
Uncertainty management in the measurements for the electric power quality analysis
2014
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors combine and propagate through the measurement chain, four approaches are proposed and validated. These approaches entail a greater and greater uncertainty overestimation, but, at the same time, require less and less time and resources. Therefore, the four methodologies are perfectly adequate for the implementation of the PUMA (Procedure for Uncertainty Management) metho…
Reference-Plane Invariant Method for Measuring Electromagnetic Parameters of Materials
2010
This paper presents a simple and effective wideband method for the determination of material properties, such as the complex index of refraction and the complex permittivity and permeability. The method is explicit (non-iterative) and reference-plane invariant: it uses a certain combination of scattering parameters in conjunction with group-velocity data. This technique can be used to characterize both dielectric and magnetic materials. The proposed method is verified experimentally within a frequency range between 2 to 18 GHz on polytetrafluoroethylene and polyvinylchloride samples. A comprehensive error and stability analysis reveals that, similar to other methods based on transmission/re…
Reactor neutrino background at the proposed LAGUNA sites
2012
Abstract The electron antineutrino background from reactors is estimated in proposed LAGUNA sites using commercial fission reactors operational in 2009. Calculations are made for an input to background studies like e.g. geoneutrino measurement uncertainty estimation.
Reduction of the uncertainty in the measurements of magnetic fields
2014
The paper deals with magnetic field measurement, carried out by using a broadband and isotropic instrument. These measurements are characterized by a very high uncertainty values if compared with the ones usually related to other electrical measurements. For these reasons, if the measurements are performed to assess the exposure of human beings, these large uncertainty values imply a high risk of wrong decision when there is the need to establish if a site complies or does not comply with a specified emission limits. A reduction of the uncertainty values implies a reduction of the risk. With this aim, we propose an approach which, in particular but very typical cases, allows an effective re…