Search results for "Measurement"
showing 10 items of 2918 documents
Transfer of Water and Active Molecules at the Interfaces in Complex Food Systems: Theoretical and Practical Aspects
2011
Abstract During processing, storage and consumption, mass transfer of various molecules (water, gases, flavour compounds or other solutes) occur between the different phases in complex food products, and/or also between the complex food and its surroundings. These mass transfers can lead to physical and/or chemical changes and thus induce food quality modifications. The objective of this presentation is to better understand the behaviour of small molecules at the interfaces, especially in model heterogeneous food systems. Different techniques have been developed to characterize their properties and their impact on the mass transfers. Particularly, techniques such as rotative diffusion cell …
Chlorine partitioning in the lowermost Arctic vortex during the cold winter 2015/2016
2019
Activated chlorine compounds in the polar winter stratosphere drive catalytic cycles that deplete ozone and methane, whose abundances are highly relevant to the evolution of global climate. The present work introduces a novel dataset of in situ measurements of relevant chlorine species in the lowermost Arctic stratosphere from the aircraft mission POLSTRACC–GW-LCYCLE–SALSA during winter 2015/2016. The major stages of chemical evolution of the lower polar vortex are presented in a consistent series of high-resolution mass spectrometric observations of HCl and ClONO2. Simultaneous measurements of CFC-12 are used to derive total inorganic chlorine (Cly) and active chlorine (ClOx). The new data…
A battery of toxicity tests as indicators of decontamination in composting oily waste.
2000
Heterogeneous oily waste from an old dumping site was composted in three windrows constructed from different proportions of waste, sewage sludge, and bark. The objectives of this pilot study were to examine the usefulness of composting as a treatment method for this particular waste and to study decontamination in the composting process by using a battery of toxicity tests. Five samples from the windrow having intermediate oil concentrations were tested with toxicity tests based on microbes (Pseudomonas putida growth inhibition test, ToxiChromotest, MetPLATE, and three different modifications of a luminescent bacterial test), enzyme inhibition (reverse electron transport), plants (duckweed …
Sun-induced fluorescence - a new probe of photosynthesis: First maps from the imaging spectrometer HyPlant.
2015
Variations in photosynthesis still cause substantial uncertainties in predicting photosynthetic CO2 uptake rates and monitoring plant stress. Changes in actual photosynthesis that are not related to greenness of vegetation are difficult to measure by reflectance based optical remote sensing techniques. Several activities are underway to evaluate the sun-induced fluorescence signal on the ground and on a coarse spatial scale using space-borne imaging spectrometers. Intermediate-scale observations using airborne-based imaging spectroscopy, which are critical to bridge the existing gap between small-scale field studies and global observations, are still insufficient. Here we present the first …
A New Simple Static Method for the Determination of Solubilities of Condensed Compounds in Supercritical Fluids
2002
Abstract A simple static method based on gravimetric measurements has been adopted to measure the solubility of benzenecarboxylic acid, 2-hydroxy-benzenecarboxylic acid, 4-hydroxy-benzenecarboxylic acid and 1,8-dihydroxyanthraquinone along several isotherms in the temperature range 318–357 K and the pressure interval 7–23 MPa. Solubility data have been correlated with the Zieger–Eckert approach, using the Fedor atomic and group contribution method to estimate the solubility parameter and the molar volume of the solutes. A good agreement was obtained between data reported in the literature and those determined using the proposed method which allows one to measure solubility mole fraction as …
Effects of ultrahigh dilutions of 3,5-dichlorophenol on the luminescence of the bacterium Vibrio fischeri.
2003
Abstract There is a great need for research in the field of homeopathy for laboratory test systems to investigate the actions of ultrahighly diluted biological effectors. With this in mind, we used the luminescent bacterium Vibrio fischeri, which is used throughout the world in testing water quality. Luminescence inhibition is utilized as a test parameter for the toxicity of a sample. We used ultrahigh dilutions (UHD) of 3,5-dichlorophenol as effector and adapted the standard test procedure for water toxicity in a way that let us evaluate very minute effects. Three groups of samples were prepared and then blinded: 45 dilutions of 3,5-dichlorophenol in steps of 10, starting with 4.2×10−2 M, …
Physicochemical stability of carfilzomib (Kyprolis®) containing solutions in glass vials, ready-to-administer plastic syringes and infusion bags over…
2017
Centralized aseptic preparation of ready-to-administer carfilzomib containing parenteral solutions in plastic syringes and polyolefine (PO) infusion bags needs profound knowledge about the physicochemical stability in order to determine the beyond-use-date of the preparations. Therefore, the purpose of this study was to determine the physicochemical stability of carfilzomib solution marketed as Kyprolis® powder for solution for infusion. Reconstituted solutions and ready-to-administer preparations of Kyprolis® stored under refrigeration (2–8℃) or at room temperature (25℃) were analyzed at predetermined intervals over a maximum storage period of 28 days. Chemical stability of carfilzomib wa…
Analytical methodologies for chromium speciation in solid matrices: a survey of literature
1998
The analytical literature about chromium speciation in solid samples has been surveyed. From 451 articles published on the speciation of chromium from 1983 to 1997, the methodologies to do speciation in solids after sample pretreatment are discussed, through consideration of the types of samples and their dissolution, the analytical techniques employed for chromium measurement, and the figures of merit of the 86 papers reported in the Analytical Abstracts data base.
Strong circularly polarized luminescence of an octahedral chromium(iii) complex
2019
The chiral spin-flip luminophore [Cr(ddpd)2]3+ can be resolved into enantiopure material by chiral HPLC. The corresponding enantiomers show very high luminescence dissymmetry factors of up to ∣glum ∣≈ 0.093 in circularly polarized luminescence (CPL) measurements for the "ruby-like" phosphorescence transition 2E/2T1 → 4A2 in the near-IR region around λ ≈ 775 nm.
Ultrasound-Guided Percutaneous Neuromodulation in Patients with Chronic Lateral Epicondylalgia: A Pilot Randomized Clinical Trial
2021
Objective: The aim was to analyze effects of a percutaneous neuromodulation (PNM) treatment on the radial nerve, regarding pain, functionality, electrophysiologic excitability, and morphology, in patients with chronic lateral epicondylalgia (LE). Methods: Twenty-four patients with chronic unilateral elbow pain were recruited for this preliminary study and were divided into two groups: control (n = 12) and PNM group (n = 12). The subjects in the PNM group received percutaneous peripheral neurostimulation with an acupuncture needle that was located next to the nerve with ultrasound guidance. Pain using a numerical rating scale (NRS), functional ability using patient-rated tennis elbow evaluat…