Search results for "Mesh"
showing 10 items of 885 documents
A minor modification of Lichtenstein repair of primary inguinal hernia: postoperative discomfort evaluation.
2010
The aim of this study was to evaluate the usefulness of a modification of the Lichtenstein hernioplasty procedure by evaluating its impact on postoperative discomfort. From December 1999 to May 2006, the Lichtenstein inguinal hernioplasty was performed in 406 patients with noncomplicated unilateral inguinal hernia. During reconstruction, the mesh was fixed to the inguinal canal floor without stitching its upper margin to the internal oblique muscle. Control of postoperative pain proved to be satisfactory; 72 hours after surgery, 26.1 per cent of patients no longer felt any pain, whereas 54.4 per cent had slight pain without the need for painkillers; on Day 7, 92.8 per cent felt no pain at …
Modified fixation free plug technique using a new 3D multilamellar implant for inguinal hernia repair: a retrospective study of a single operator cas…
2013
Aim: Implant fixation, mesh shrinkage and poor quality of tissue ingrowth are unresolved issues in modern hernia repair. Many complications reported in the literature such as bleeding, nerve entrapment, hematoma, pain, discomfort, and testicular complications, are considered to be a direct results of implant fixation. This article describes the outcomes of a procedure carried out using a handcrafted implant that addresses the issues consequent to point fixation. Methods: This was a retrospective study on the short, medium and long-term results of placing a-modified, fixation free three-dimensional polypropylene implant in 61 patients who underwent inguinal hernia repair using a novel delive…
New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Tentacle-shaped mesh for fixation-free repair of umbilical hernias
2019
Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…
PTFE mesh in renal allograft compartment syndrome.
2006
We report a case of anuria in a 42-year-old female kidney transplant patient that occurred secondary to extrinsic compression from a large kidney being placed extraperitoneally in a small iliac fossa. Prompt reexploration in the immediate postoperative period resulted in salvage of the graft with restoration of kidney function. The abdominal wall was reconstructed using prosthetic mesh, which decreased the compartment pressure within the iliac fossa sufficiently to allow the renal vein patency and the kidney perfusion. We think that this tension-free surgical technique should be applied in those cases in which the retroperitoneal space is less than the size of the kidney to avoid renal allo…
Acute inflammatory response in the subcutaneous versus periprosthethic space after incisional hernia repair: an original article.
2014
BACKGROUND: The acute inflammatory response following mesh implantation has been often evaluated in vitro and in animal models. The aim of this study was to evaluate the acute inflammatory response near the prosthesis in human by analysing some inflammatory indicators.METHODS: We used a cohort of twelve male patients affected by midline incisional hernia, who were admitted for surgical mesh repair. A suction drain was placed between the mesh and rectal muscles whereas, the other one was placed between the subcutaneous tissue and the oblique external sheath. The acute inflammatory response was analyzed by measuring the production of interleukin [IL]-1, IL-10, IL-1ra, C-Reactive Protein (CRP)…
Intraperitoneal Onlay Mesh Technique for Spigelian Hernia in an Outpatient and Short-Stay Surgery Unit: What's New in Intraperitoneal Meshes?
2018
Spigelian hernia (SH) is a rare entity, but its surgical treatment is essential because of its high complication risk. Laparoscopic approaches have become the option in elective surgery because it has less morbidity and requires a shorter stay. Several laparoscopic techniques have been employed, but there is no gold standard technique for this kind of hernia. We report, in this study, our experience with intraperitoneal onlay mesh (IPOM) repair.Fifteen patients underwent elective surgery for SH between 2008 and 2015 in a Short-Stay Surgical Unit. Laparoscopic IPOM technique was performed in all patients. The technique, epidemiological data, operative findings, hospital stay, morbidity, and …
Frequency of NOD2/CARD15 variants in both sporadic and familial cases of Crohn's disease across Italy. An Italian Group for Inflammatory Bowel Diseas…
2004
Abstract Background. Three variants of the NOD 2 /CARD 15 gene are strongly associated with susceptibility to Crohn’s disease; however, striking racial and geographic differences of their frequency have been described. Aims. We have compared the allele frequencies of familial cases of Crohn’s disease recruited in a multicentre study across Italy, in order to disclose possible geographic heterogeneity. Moreover, we also compared the allele frequencies in sporadic cases of Crohn’s disease and healthy controls from Southern Italy with those reported in other two populations from Central and Northern Italy. Subjects and Methods. A total of 731 subjects were genotyped for the polymorphism of thr…
Partial versus complete removal of the infected mesh after abdominal wall hernia repair.
2017
Background: To compare the results with complete mesh removal (CMR) versus partial mesh removal (PMR) in the treatment of mesh infection after abdominal wall hernia repair (AWHR). Methods: Retrospective review of all patients who underwent surgery for mesh infection between January 2004 and May 2014 at a tertiary center. Results: Of 3470 cases of AWHR, we reported 66 cases (1.9%) of mesh infection, and 48 repairs (72.7%) required mesh explantation. CMR was achieved on 38 occasions, while PMR was undertaken ten times. We observed more postoperative complications in CMR than PMR group (p = 0.04). Three patients with intestinal fistula were reoperated in postoperative period after a difficult …
Predictors of mesh infection and explantation after abdominal wall hernia repair
2015
Abstract Background The main objective was to identify predictive factors associated with prosthesis infection and mesh explantation after abdominal wall hernia repair (AWHR). Methods This is a retrospective review of all patients who underwent AWHR from January 2004 to May 2014 at a tertiary center. Multivariate analysis identified predictors of mesh infection and explantation after AWHR. Results From 3,470 cases of AWHR, we reported 66 cases (1.9%) of mesh infection, and 48 repairs (72.7%) required mesh explantation. Steroid or immunosuppressive drugs use (odds ratio [OR] 2.22; confidence interval [CI] 1.16 to 3.95), urgent repair (OR 5.06; CI 2.21 to 8.60), and postoperative surgical sit…