Theoretical prediction of the native fluorescence of pharmaceuticals
2009
At present, to search fluorescent compounds or to increase the native fluorescence is an active research line specially and not only with analytical purposes. On some analytical areas and from the early times of applications of fluorescence (mid-fifties) the fluorimeter was defined as the suitable detector for determination of pharmaceuticals and subsequently, this detection mode has been widely applied. Therefore, it is mandatory to develop new strategies to discover or to enhance in a simple way the native fluorescence of organic compounds to increase the number of analytes to be determined by direct fluorescence. In the present paper are studied further applications of a new tool suitabl…
First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas
2014
The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…
Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold
2021
Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…
2015
A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…
Photon absorption by aqueous TiO2 dispersion contained in a stirred photoreactor
1991
We present a simple experimental method which allows the evaluation of the absorbed photon flow. The method is based on measurements of transmitted photon rates (by means of standard actinometer solutions) for different reactor thicknesses and/or catalyst concentrations. The method was applied to phenol degradation reaction carried out in a stirred batch phtotoreactor containing aqueous TiO 2 (anatase) dispersion, directly irradied by a 1,500 W Xe lamp
A method for the surface reflectance retrieval from PROBA/CHRIS data over land: application to ESA SPARC campaigns
2005
The Compact High Resolution Imaging Spectrometer (CHRIS) onboard the Project for On-Board Autonomy (PROBA) platform system provides the first high spatial resolution hyper-spectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. A fully consistent radiative transfer approach is always preferred when dealing with the retrieval of surface reflectance from hyperspectral/multiangular data. However, due to the reported calibration anomalies for CHRIS data, a direct atmospheric correction based on physical radiative transfer modeling is not possible, and the method must somehow compensate for such calibration pr…
Exploring the validity of the long term data record V4 database for land surface monitoring
2015
The last (and final) version of the Long Term Data Record (LTDR) — Version 4 — has been released recently by NASA. This database includes daily information for all AVHRR (Advanced Very High Resolution Radiometer) channels, as well as ancillary data, since July 1981 up to present. This database is the longest available record of remotely sensed data useful for land surface monitoring, since it allows the estimation of vegetation indices at daily resolution, as well as the daily estimation of land surface temperature (LST). Here, we analyze the fitness of this database for land surface monitoring. To that end, we first estimated NDVI (Normalized Difference Vegetation Index), LST, as well as e…
A study of the effect of molecular and aerosol conditions in the atmosphere on air fluorescence measurements at the Pierre Auger Observatory
2010
The air fluorescence detector of the Pierre Auger Observatory is designed to perforin calorimetric measurements of extensive air showers created by Cosmic rays of above 10(18) eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group Of monitoring instruments to record atmospheric conditions across the detector site, ail area exceeding 3000 km(2). The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierr…
Comparison of aerosol size distributions measured at ground level and calculated from inversion of solar radiances
2005
Ground-based sunphotometry measurements can be used to investigate atmospheric aerosol optical properties, such as the volume size distribution, an important parameter in the study of the effect of aerosol on atmospheric processes. Most inversion algorithms assume constant aerosol optical characteristics over the whole air column. In this work we present observational evidence of the limitations of this simplifying assumption in cases where the aerosol vertical structure is highly inhomogeneous. During the field campaign VELETA 2002, carried out in Granada (Spain), a quite complete characterization of the atmospheric aerosol was obtained by simultaneously measuring the columnar aerosol char…